Transcatheter mitral valve implantation in rigid mitral annuloplasty rings: Potential differences between complete and incomplete rings

2018 ◽  
Vol 93 (1) ◽  
pp. E71-E74 ◽  
Author(s):  
Daisuke Hachinohe ◽  
Azeem Latib ◽  
Matteo Montorfano ◽  
Antonio Colombo
Author(s):  
Harish Sharma ◽  
Adnan Nadir ◽  
Richard P Steeds ◽  
Sagar N Doshi

Abstract Background Annuloplasty failure caused by ring dehiscence can lead to trans-ring and para-ring mitral regurgitation. Transcatheter treatments are available for patients at prohibitive risk of surgery. In patients unsuitable for edge-to-edge repair, valve-in-ring transcatheter mitral valve implantation has been described to treat trans-ring or para-ring jets but not both concurrently. Case summary A 78-year-old male presented with severe mitral regurgitation due to dehiscence of a 34 mm Edwards Physio II mitral annuloplasty ring. Transesophageal echocardiography showed two jets of regurgitation; trans-ring and para- ring. Repair was successfully undertaken with a valve-in-ring procedure (29 mm S3 Edwards Lifesciences). Discussion Patients with failure of mitral valve annuloplasty with trans-ring and para-ring regurgitation can be safely and effectively treated by valve-in-ring transcatheter mitral valve implantation.


2012 ◽  
Vol 60 (S 01) ◽  
Author(s):  
M Endlich ◽  
F Mellert ◽  
J Breuer ◽  
U Herberg ◽  
I Heinze ◽  
...  

2012 ◽  
Vol 60 (S 01) ◽  
Author(s):  
M Seiffert ◽  
L Conradi ◽  
S Baldus ◽  
J Schirmer ◽  
M Knap ◽  
...  

2014 ◽  
Vol 62 (S 01) ◽  
Author(s):  
C. Schmitz ◽  
R. Schramm ◽  
A.L. Hoffmann ◽  
R. Sodian ◽  
C. Hagl ◽  
...  

Author(s):  
Gabrielle M. Colvert ◽  
Ashish Manohar ◽  
Francisco J. Contijoch ◽  
James Yang ◽  
Jeremy Glynn ◽  
...  

Author(s):  
Ashvarya Mangla ◽  
Ameer Musa ◽  
Clifford J Kavinsky ◽  
Hussam S Suradi

Abstract Background Transcatheter mitral valve-in-valve implantation (MVIV) has emerged as a viable treatment option in patients at high risk for surgery. Occasionally, despite appropriate puncture location and adequate dilation, difficulty is encountered in advancing the transcatheter heart valve across interatrial septum. Case summary We describe a case of a 79-year-old woman with severe chronic obstructive pulmonary disease (COPD), prior surgical bioprosthetic aortic and mitral valve replacement implanted in 2007, atrial fibrillation, and Group II pulmonary hypertension who presented with progressively worsening heart failure symptoms secondary to severe bioprosthetic mitral valve stenosis and moderate-severe mitral regurgitation. Her symptoms had worsened over several months, with multiple admissions at other institutions with treatment for both COPD exacerbation and heart failure. Transoesophageal echocardiogram demonstrated preserved ejection fraction, normal functioning aortic valve, and dysfunctional mitral prosthesis with severe stenosis (mean gradient 13 mmHg) and moderate-severe regurgitation. After a multi-disciplinary heart team discussion, the patient underwent a transcatheter MVIV implantation. During the case, inability in advancing the transcatheter heart valve (THV) across interatrial septum despite adequate septal balloon pre-dilation was successfully managed with the support of a stiff ‘buddy wire’ anchored in the left upper pulmonary vein using the same septal puncture. The patient tolerated the procedure well and was discharged home. Discussion Operators should be aware of potential strategies to advance the THV when difficulty is encountered in crossing the atrial septum despite adequate septal preparation. One such strategy is the use of stiff ‘buddy wire’ for support which avoids the need for more aggressive septal dilatation.


Sign in / Sign up

Export Citation Format

Share Document