Stereotactic image-guided navigation in the preoperative imaging of perforators for DIEP flap breast reconstruction

Microsurgery ◽  
2008 ◽  
Vol 28 (6) ◽  
pp. 417-423 ◽  
Author(s):  
W. M. Rozen ◽  
M. W. Ashton ◽  
D. L. Stella ◽  
T. J. Phillips ◽  
G. I. Taylor
2011 ◽  
Vol 128 (1) ◽  
pp. 56-62 ◽  
Author(s):  
Mark V. Schaverien ◽  
Catherine N. Ludman ◽  
Jason Neil-Dwyer ◽  
Graeme B. Perks ◽  
Nadeem Akhtar ◽  
...  

2010 ◽  
Vol 162 (1) ◽  
pp. 140-147 ◽  
Author(s):  
Purificación Gacto-Sánchez ◽  
Domingo Sicilia-Castro ◽  
Tomás Gómez-Cía ◽  
Araceli Lagares ◽  
Teresa Collell ◽  
...  

2014 ◽  
Vol 30 (S 01) ◽  
Author(s):  
Carmen Suñé ◽  
David Carrillo ◽  
Cristian Lopez ◽  
Marco Serena Signes ◽  
Alejandra Sainz ◽  
...  

2005 ◽  
Vol 21 (07) ◽  
Author(s):  
Koenraad Landuyt ◽  
Moustapha Hamdi ◽  
Phillip Blondeel ◽  
Nathalie Roche ◽  
Stanislas Monstrey

Author(s):  
Anouk A. M. A. Lindelauf ◽  
Nousjka P. A. Vranken ◽  
Rutger M. Schols ◽  
Esther A. C. Bouman ◽  
Patrick W. Weerwind ◽  
...  

Abstract Early detection of vascular compromise after autologous breast reconstruction is crucial to enable timely re-exploration for flap salvage. Several studies proposed non-invasive tissue oximetry for early identification of ischemia of deep inferior epigastric perforator (DIEP) flaps. The present study aimed to explore the utility of non-invasive tissue oximetry following DIEP flap surgery using a personalized oxygenation threshold. Methods Patients undergoing immediate/delayed DIEP flap surgery were included in this prospective observational study. DIEP flap tissue oxygenation (StO2) was monitored continuously using near-infrared spectroscopy. A baseline measurement was performed by positioning one sensor at the marked position of the major inferior epigastric perforator on the abdomen. A new sensor was positioned postoperatively on the transplanted tissue. In unilateral procedures, postoperative StO2 values of the native breast were also obtained. Measurements were continued for 24 h. Results Thirty patients (42 flaps) were included. Fourteen patients (46.7%) had an uncomplicated postoperative course. A minor complication was observed in thirteen patients; in five patients, at least one major complication occurred, requiring re-exploration. Median StO2 readings were significantly lower in patients with major complications compared to uncomplicated cases. In fourteen unilateral DIEP flap procedures, StO2 values of the native breast were similar to the preoperative baseline measurement (92%; p = 0.452). Conclusions Non-invasive tissue oximetry following DIEP flap surgery could aid in early detection of vascular compromise. StO2 values of the native breast and abdominal wall preoperatively can be used interchangeably and can serve as personalized reference value. Level of evidence: Level IV, diagnostic / prognostic study.


Author(s):  
Linda Tallroth ◽  
Håkan Brorson ◽  
Nathalie Mobargha ◽  
Patrik Velander ◽  
Stina Klasson ◽  
...  

Abstract Background Objectively measured breast softness in reconstructed breasts and its relation to patients’ subjective satisfaction with breast softness has not yet been investigated. The aim of this study was to evaluate breast softness in patients 1 year following delayed breast reconstruction with an expander prosthesis (EP) or deep inferior epigastric perforator (DIEP) flap, using objective and subjective methods. Methods Seventy-three patients were randomised to breast reconstruction with an EP or DIEP flap between 2012 and 2018. Of these, 69 completed objective evaluation at a mean of 25 (standard deviation, SD 9.4) months following breast reconstruction. Objective evaluation included measurements of breast volume, jugulum-nipple distance, clavicular-submammary fold distance, ptosis and Baker scale grading. Breast softness was assessed with applanation tonometry. Subjective evaluation was performed using the BREAST-Q questionnaire. Results Objectively, DIEP flaps were significantly softer than EP breast reconstructions. Non-operated contralateral breasts were significantly softer compared with reconstructed breasts. In the subjective evaluation, the median score on the question (labelled 1.h) “How satisfied or dissatisfied have you been with the softness of your reconstructed breast (s)?” was higher in the DIEP flap group corresponding to greater satisfaction in this group. A fair correlation was found between the applanation tonometry and the patient-reported satisfaction with the reconstructed breast’s softness (rs = 0.37). Conclusions In terms of breast softness, breast reconstructions with DIEP flaps result in more satisfied patients. Concerning applanation tonometry as an objective tool for softness assessment, future studies on interobserver agreement are warranted. Level of evidence: Level I, therapeutic study


Sign in / Sign up

Export Citation Format

Share Document