scholarly journals Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor

2012 ◽  
Vol 39 (3) ◽  
pp. 310-315 ◽  
Author(s):  
E. A. Torkildsen ◽  
K. Å. Salvesen ◽  
T. M. Eggebø
2019 ◽  
Vol 54 (S1) ◽  
pp. 97-97
Author(s):  
A. Youssef ◽  
M. Dodaro ◽  
G. Di Donna ◽  
L. Bianchini ◽  
F. Bellussi ◽  
...  

2008 ◽  
Vol 32 (3) ◽  
pp. 390-391
Author(s):  
C. E. Macpherson ◽  
F. Lovegrove ◽  
S. Harris ◽  
K. D. Kalache ◽  
G. Michailidis

2014 ◽  
Vol 43 (2) ◽  
pp. 183-188 ◽  
Author(s):  
A. Youssef ◽  
F. Bellussi ◽  
E. Montaguti ◽  
E. Maroni ◽  
G. Salsi ◽  
...  

Author(s):  
Hale Göksever Çelik ◽  
Engin Çelik ◽  
Gökhan Yıldırım

Background: Digital cervical evaluation has been used to determine the likelihood of vaginal delivery which is considered by many women to be non-tolerable. Recently, transperineal ultrasound allowing direct visualization of the fetal skull has been using for the prediction of labor route. Authors aimed to study whether measurements on transperineal ultrasound are predictive for vaginal delivery in pregnant women induced with dinoprostone at 40.0-42.0 gestational weeks.Methods: A total of 55 pregnant women at 40.0-42.0 gestational weeks were enrolled in this prospective observational study. All participated women were examined before the induction with dinoprostone to measure the head-perineum distance (HPD), the head-pubis distance and the angle of progression of fetal head (AOP).Results: The greater AOP, the shorter HPD and the head-pubis distance were associated with vaginal delivery in the nulliparous women. The HPD and the head-pubis distance were shorter, whereas the AOP was greater in the multiparous women giving birth by vaginal route.Conclusions: Transperineal ultrasound can be applied at the beginning of labor to predict whether vaginal delivery will occur or not. As shown in our study, the pregnant women with shorter HPD and wider AOP might have a high possibility to achieve vaginal delivery.


2021 ◽  
Vol 9 (B) ◽  
pp. 1037-1043
Author(s):  
Gamal Abdelsameea Ibrahim ◽  
Ahmed Soliman Nasr ◽  
Fatma Atta ◽  
Mohamed Reda ◽  
Hend Abdelghany ◽  
...  

Introduction: High fetal head station has been associated with prolonged labor and delivery outcomes. Although clinical assessment of fetal head station is both subjective and unreliable, women with prolonged labor are subjected to multiple digital vaginal examinations. The use of ultrasound has been proposed to aid in the management of labor since 1990s. Ultrasound examination is more accurate and reproducible than clinical examination in the diagnosis of fetal head station and in the prediction of arrest of labor. Ultrasound examination can, to some extent, distinguish those women destined for spontaneous vaginal delivery and those destined for operative delivery and  may predict the outcome of instrumental vaginal delivery. Such a technique has the potential to reduce the frequency of intrusive internal examinations and associated infection and could be useful in allowing the assessment of women in whom digital VE is traumatic or contra-indicated. Intrapartum ultrasound not only provides objective and quantitative data in labor, but also helps to make more reliable clinical decisions aiming to improve obstetric outcomes of both the mother and fetus as a supplementary tool for active management. Aim of the work: This study aims at assessing the value of intrapartum transperineal ultrasonography as a quantitative and objective tool in the evaluation of progress of labor and prediction of mode of delivery. Subjects: This study was a prospective observational study conducted on 600 primiparous women in active first stage of labor admitted to Kasr Al Ainy maternity hospital from January 2017 to June 2018. The studied population was divided into two groups. Group A of 300 women with normal progress of labor and group B of 300 women with prolonged 1st stage of labor. Methods: Fetal head station(FHS) was assessed clinically by digital vaginal examination (dVE) and sonographically by transperineal ultrasound measurement of  head perineal distance (HPD) and angle of progression (AOP). Intrapartum care of the patient continued as normal based only on digital vaginal examinations using the modified WHO partogram. (1). Statistical analysis was targeted towards assessing the potential of the intrapartum ultrasonography in the evaluation of progress of labor and prediction of mode of delivery. Results: All studied parameters for assessment of FHS (dVE, HPD, and AOP) significantly corelated with each other and with both progress of labor and mode of delivery with P value (<0.001). The highest sensitivity for prediction of progress of labor is observed using dVE (83%), the highest specificity is observed using AOP (78.3%). The highest sensitivity for prediction mode of delivery is for combined HPD & AOP (97.7%) while the highest specificity is for AOP (81%). When combining both HPD and AOP for prediction of mode of delivery, the assessment of both parameters was found to have a high sensitivity of 97.7% and a high positive predictive value of 86.63%. Conclusion: Intrapartum ultrasound examination is a valuable tool in the prediction of progress of labor and mode of delivery. The assessment of fetal head station by transperineal ultrasound measurement of HPD and AOP is much more informative of the progress of labor and the mode of delivery than digital assessment of fetal head station. Keywords: Labor, intrapartum ultrasound, Angle of progression, Head perineal distance, fetal head station, digital vaginal examination.


QJM ◽  
2021 ◽  
Vol 114 (Supplement_1) ◽  
Author(s):  
Hesham Mohammed Fathy ◽  
Ahmed Mohammed Bahaa El-Din ◽  
Haitham Fathy Mohammed ◽  
Mohammed Mahmoud Mohammed Helmy

Abstract Background Labor is a physiologic process during which the products of conception (i.e. the fetus, membranes, umbilical cord, and placenta) are expelled outside of the uterus. Labor is achieved with changes in the biochemical connective tissue and with gradual effacement and dilatation of the uterine cervix as a result of rhythmic uterine contractions of sufficient frequency, intensity, and duration. Labor is divided into three stages that include cervical dilatation, fetal delivery and delivery of the placenta. Objective The aims of this study were to quantify the degree of fetal head deflection via the use of Ultrasound during the first stage of labor and to determine whether a parameter derived from ultrasound examination (the occiput-spine angle) has a relationship with the progress of labor, subsequent effect on maternal, fetal complications and rate of cesarean delivery. Methods This is a prospective cohort study which includes a total of 200 women with gestational age 37-42 weeks were assessed in this study in Ain shams Maternity hospital labor ward by 2 dimensional ultra sound. Examinations were performed after a verbal and written consent from the patient with the patient lying in the dorsal supine position. And exclusion of Occiput-posterior position, multigravida, Indication for cesarean, Medical disorder eg hypertension or diabetes, pre labor rupture of membranes to correlate between the Occiput- spine angle (OSA) and the outcome of labor regarding the progress of labor, incidence of cesarean section, maternal and fetal complications. Results This study demonstrates that the sonographic measurement of the angle formed by the fetal occiput and the spine (occiput-spine angle) is feasible and reproducible, the occiput-spine angle in the first stage of labor is positively correlated with the clinically established station and the risk of obstructed labor requiring an operative delivery ie, Occiput-spine angle have been statistically significantly lower in cases underwent operative delivery. Occiput-spine angle had a statistically significant low diagnostic performance in predicting operative delivery. Conclusion The occiput-spine angle in the first stage of labor correlates significantly with the risk of obstructed labor Compared with spontaneous vaginal deliveries, cases that require obstetric intervention demonstrated a smaller occiput-spine angle at a similar station, suggesting diminished flexion of the fetal head. For occiput anterior fetuses, the greater the degree of fetal head deflexion, the greater risk of operative delivery due to labor arrest.


2019 ◽  
Vol 53 (2) ◽  
pp. 272-273 ◽  
Author(s):  
A. Youssef ◽  
E. Margarito ◽  
A. Cappelli ◽  
C. Mosconi ◽  
M. Renzulli ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document