In Vivo and In Vitro Uptake Study of Boronated Porphyrins for Neutron Capture Therapy

Author(s):  
Akira Matsumura ◽  
Yasushi Shibata ◽  
Tetsuya Yamamoto ◽  
Fumiyo Yoshida ◽  
Kei Nakai ◽  
...  
1999 ◽  
Vol 141 (1-2) ◽  
pp. 203-209 ◽  
Author(s):  
Akira Matsumura ◽  
Yasushi Shibata ◽  
Tetsuya Yamamoto ◽  
Fumiyo Yoshida ◽  
Tomonori Isobe ◽  
...  

2000 ◽  
Vol 155 (2) ◽  
pp. 209
Author(s):  
Akira Matsumura ◽  
Yasushi Shibata ◽  
Tetsuya Yamamoto ◽  
Fumiyo Yoshida ◽  
Tomonori Isobe ◽  
...  

2016 ◽  
Vol 1 (2) ◽  
pp. 108
Author(s):  
Widarto Widarto ◽  
Isman Mulyadi Tri Atmoko ◽  
Gede Sutresna Wijaya

The quality manajement system program of in vitro / in vivo test facility of  Boron Neutron Capture Therapy (BNCT) methode as quality assurance requirement for utilization of radial pearcing beamport of Kartini research have been done.  Identification and management of technical specification and parameters meassurement of to the radial piercing beamport have been determined for preparing in vitro / in vivo test facility. The parameters are epithermal neutron flux is  9,8243E+05  n cm<sup>-2</sup> s<sup>-1</sup>and  thermal neutron flux is 3,0691E+06 n cm<sup>-2</sup> s<sup>-1</sup>, radiation shielding of parafin,  dimension and size  of piercing radial and instrumentatin and control system for automatic transfer of in vitro / in vivo samplels have been documented. Management system of the documents for fullfil  basic guidance to perform working job of in vitro / in vivo at the piercing radial beamport of Kartini Research Reactor in order purpose utilization of the reactor  for safety worker of the radiation area, society  and invironment beeing safely


2018 ◽  
Author(s):  
Guillaume Vares ◽  
Vincent Jallet ◽  
Yoshitaka Matsumoto ◽  
Cedric Rentier ◽  
Kentaro Takayama ◽  
...  

AbstractTreatment resistance, relapse and metastasis remain critical issues in some challenging cancers, such as chondrosarcomas. Boron-neutron Capture Therapy (BNCT) is a targeted radiation therapy modality that relies on the ability of boron atoms to capture low energy neutrons, yielding high linear energy transfer alpha particles. We have developed an innovative boron-delivery system for BNCT, composed of multifunctional fluorescent mesoporous silica nanoparticles (B-MSNs), grafted with an activatable cell penetrating peptide (ACPP) for improved penetration in tumors and with Gadolinium for magnetic resonance imaging (MRI)in vivo. Chondrosarcoma cells were exposedin vitroto an epithermal neutron beam after B-MSNs administration. BNCT beam exposure successfully induced DNA damage and cell death, including in radio-resistant ALDH+ cancer stem cells (CSCs), suggesting that BNCT using this system might be a suitable treatment modality for chondrosarcoma or other hard-to-treat cancers.


Biomedicines ◽  
2021 ◽  
Vol 9 (1) ◽  
pp. 74
Author(s):  
Tatyana V. Popova ◽  
Inna A. Pyshnaya ◽  
Olga D. Zakharova ◽  
Andrey E. Akulov ◽  
Oleg B. Shevelev ◽  
...  

Multifunctional gold nanoparticles (AuNPs) may serve as a scaffold to integrate diagnostic and therapeutic functions into one theranostic system, thereby simultaneously facilitating diagnosis and therapy and monitoring therapeutic responses. Herein, albumin-AuNP theranostic agents have been obtained by conjugation of an anticancer nucleotide trifluorothymidine (TFT) or a boron-neutron capture therapy drug undecahydro-closo-dodecaborate (B12H12) to bimodal human serum albumin (HSA) followed by reacting of the albumin conjugates with AuNPs. In vitro studies have revealed a stronger cytotoxicity by the AuNPs decorated with the TFT-tagged bimodal HSA than by the boronated albumin conjugates. Despite long circulation time, lack of the significant accumulation in the tumor was observed for the AuNP theranostic conjugates. Our unique labelling strategy allows for monitoring of spatial distribution of the AuNPs theranostic in vivo in real time with high sensitivity, thus reducing the number of animals required for testing and optimizing new nanosystems as chemotherapeutic agents and boron-neutron capture therapy drug candidates.


2016 ◽  
Vol 1 (1) ◽  
pp. 54
Author(s):  
Ranti Warfi ◽  
Andang Widi Harto ◽  
Yohannes Sardjono ◽  
Widarto Widarto

<span>The optimization of thermal column collimator has been studied which resulted epithermal neutron beam for in vivo and in vitro trials of Boron Neutron Capture Therapy (BNCT) at Kartini Research Reactor of 100 kW by means of </span><em>Monte Carlo N-Particle Extended </em><span>(MCNP-X) codes. The design criteria were based on recommendation from the International Atomic Energy Agency (IAEA). MCNP-X calculations indicated by using 5 cm thickness of Ni as collimator wall, 30 cm thickness of Al as moderator, 20 cm thickness of 60Ni as filter, 2 cm thickness of Bi as γ-ray shielding, 3 cm thickness of 6Li2CO3-polyethylene as beam delimiter, and for in vivo in vitro trials purpose, aperture was designed 8 cm radius size, an epitermal neutron beam with an intensity 1.13E+09 n.cm-2.s-1, fast neutron and γ-doses per epithermal neutron of 1.76E-13 Gy.cm2.n-1 and 1.45E-13Gy.cm2.n-1,minimum thermal neutron per epithermal neutron ratio of 0.008,and maximum directionality of 0.73, respectively could be produced. The results have passed all the IAEA’s criteria.</span>


2016 ◽  
Vol 1 (2) ◽  
pp. 63
Author(s):  
Adrian Tesalonika ◽  
Andang Widi Harto ◽  
Yohannes Sardjono ◽  
Isman Mulyadi Triatmoko

<span>A dosimetry study of in vitro and in vivo trials system in thermal column of Kartini Reactor for Boron Neutron Capture Therapy (BNCT) facility has been conducted by using the Monte Carlo N-Particle Extended (MCNPX) software. Source of neutron originated from the 100 kW reactor which has been modified by the previous researcher. Models have been made by using simple geometries to represent tissues. Models of in vitro have been made by 4 spheres each has 1 cm diameter to represent tumour, whereas in vivo by 4 cylinders each has 6 cm length, 3 cm diameter, and breast soft tissue material with 1 cm sphere each located in the center of the cylinders to represent models of mouse with tumour. An increase in value of the boron concentration will increase the value of dose rate as well, then the exposure time should be shorter. The exposure times (in minutes) of in vitro trials for 20, 25, 30, 50, 75, 100, 125, and 150 μg boron/g tissues are 117.77, 117.77, 117.07, 115.69, 114.02, 112.39, 110.80, and 109.27. Whereas the exposure times of in vivo trials are 163.58, 162.78, 161.98, 158.88, 155.16, 151.61, 148.22, dan 144.98. In vitro trials have greater values of dose rate so that in vitro trials have shorter exposure time.</span>


1970 ◽  
Vol 64 (4) ◽  
pp. 687-695 ◽  
Author(s):  
Junzo Kato

ABSTRACT The anterior, middle, and posterior hypothalamus, the cortex cerebri, the anterior hypophysis as well as the diaphragm of adult ovariectomized rats were incubated in vitro with tritiated 17β-oestradiol. The uptake of tritiated oestradiol was differentially distributed intracerebrally with higher accumulation in the anterior hypothalamus and the hypophysis. Lowering the temperature of the incubation medium caused a reduction in the uptake of radioactivity by the anterior hypothalamus as compared to that found in other brain tissues. Tritiated oestradiol taken up in vitro by the anterior hypothalamus and the hypophysis tended to be retained after further incubation in a steroid-free medium. The addition of non-radioactive 17β-oestradiol to the medium inhibited the uptake of tritiated oestradiol by these tissues. Moreover, pretreatment with non-radioactive 17β-oestradiol in vivo prevented the preferential accumulation of tritiated oestradiol in vitro in the anterior hypothalamus and the hypophysis. These results indicate that oestradiol is preferentially taken up in vitro by the anterior hypothalamus and the hypophysis of the rat.


Sign in / Sign up

Export Citation Format

Share Document