Sorption of CH4 and CO2 on Belgium Carboniferous Shale Using a Manometric Set-up

Author(s):  
Roozbeh Khosrokhavar
Keyword(s):  
Author(s):  
T. G. Naymik

Three techniques were incorporated for drying clay-rich specimens: air-drying, freeze-drying and critical point drying. In air-drying, the specimens were set out for several days to dry or were placed in an oven (80°F) for several hours. The freeze-dried specimens were frozen by immersion in liquid nitrogen or in isopentane at near liquid nitrogen temperature and then were immediately placed in the freeze-dry vacuum chamber. The critical point specimens were molded in agar immediately after sampling. When the agar had set up the dehydration series, water-alcohol-amyl acetate-CO2 was carried out. The objectives were to compare the fabric plasmas (clays and precipitates), fabricskeletons (quartz grains) and the relationship between them for each drying technique. The three drying methods are not only applicable to the study of treated soils, but can be incorporated into all SEM clay soil studies.


Author(s):  
T. Gulik-Krzywicki ◽  
M.J. Costello

Freeze-etching electron microscopy is currently one of the best methods for studying molecular organization of biological materials. Its application, however, is still limited by our imprecise knowledge about the perturbations of the original organization which may occur during quenching and fracturing of the samples and during the replication of fractured surfaces. Although it is well known that the preservation of the molecular organization of biological materials is critically dependent on the rate of freezing of the samples, little information is presently available concerning the nature and the extent of freezing-rate dependent perturbations of the original organizations. In order to obtain this information, we have developed a method based on the comparison of x-ray diffraction patterns of samples before and after freezing, prior to fracturing and replication.Our experimental set-up is shown in Fig. 1. The sample to be quenched is placed on its holder which is then mounted on a small metal holder (O) fixed on a glass capillary (p), whose position is controlled by a micromanipulator.


Author(s):  
O.L. Krivanek ◽  
J. TaftØ

It is well known that a standing electron wavefield can be set up in a crystal such that its intensity peaks at the atomic sites or between the sites or in the case of more complex crystal, at one or another type of a site. The effect is usually referred to as channelling but this term is not entirely appropriate; by analogy with the more established particle channelling, electrons would have to be described as channelling either through the channels or through the channel walls, depending on the diffraction conditions.


Author(s):  
David C. Joy ◽  
Dennis M. Maher

High-resolution images of the surface topography of solid specimens can be obtained using the low-loss technique of Wells. If the specimen is placed inside a lens of the condenser/objective type, then it has been shown that the lens itself can be used to collect and filter the low-loss electrons. Since the probeforming lenses in TEM instruments fitted with scanning attachments are of this type, low-loss imaging should be possible.High-resolution, low-loss images have been obtained in a JEOL JEM 100B fitted with a scanning attachment and a thermal, fieldemission gun. No modifications were made to the instrument, but a wedge-shaped, specimen holder was made to fit the side-entry, goniometer stage. Thus the specimen is oriented initially at a glancing angle of about 30° to the beam direction. The instrument is set up in the conventional manner for STEM operation with all the lenses, including the projector, excited.


Author(s):  
T.S. Savage ◽  
R. Ai ◽  
D. Dunn ◽  
L.D. Marks

The use of lasers for surface annealing, heating and/or damage has become a routine practice in the study of materials. Lasers have been closely looked at as an annealing technique for silicon and other semiconductors. They allow for local heating from a beam which can be focused and tuned to different wavelengths for specific tasks. Pulsed dye lasers allow for short, quick bursts which can allow the sample to be rapidly heated and quenched. This short, rapid heating period may be important for cases where diffusion of impurities or dopants may not be desirable.At Northwestern University, a Candela SLL - 250 pulsed dye laser, with a maximum power of 1 Joule/pulse over 350 - 400 nanoseconds, has been set up in conjunction with a Hitachi UHV-H9000 transmission electron microscope. The laser beam is introduced into the surface science chamber through a series of mirrors, a focusing lens and a six inch quartz window.


Author(s):  
K.-H. Herrmann ◽  
E. Reuber ◽  
P. Schiske

Aposteriori deblurring of high resolution electron micrographs of weak phase objects can be performed by holographic filters [1,2] which are arranged in the Fourier domain of a light-optical reconstruction set-up. According to the diffraction efficiency and the lateral position of the grating structure, the filters permit adjustment of the amplitudes and phases of the spatial frequencies in the image which is obtained in the first diffraction order.In the case of bright field imaging with axial illumination, the Contrast Transfer Functions (CTF) are oscillating, but real. For different imageforming conditions and several signal-to-noise ratios an extensive set of Wiener-filters should be available. A simple method of producing such filters by only photographic and mechanical means will be described here.A transparent master grating with 6.25 lines/mm and 160 mm diameter was produced by a high precision computer plotter. It is photographed through a rotating mask, plotted by a standard plotter.


Author(s):  
Vijay Krishnamurthi ◽  
Brent Bailey ◽  
Frederick Lanni

Excitation field synthesis (EFS) refers to the use of an interference optical system in a direct-imaging microscope to improve 3D resolution by axially-selective excitation of fluorescence within a specimen. The excitation field can be thought of as a weighting factor for the point-spread function (PSF) of the microscope, so that the optical transfer function (OTF) gets expanded by convolution with the Fourier transform of the field intensity. The simplest EFS system is the standing-wave fluorescence microscope, in which an axially-periodic excitation field is set up through the specimen by interference of a pair of collimated, coherent, s-polarized beams that enter the specimen from opposite sides at matching angles. In this case, spatial information about the object is recovered in the central OTF passband, plus two symmetric, axially-shifted sidebands. Gaps between these bands represent "lost" information about the 3D structure of the object. Because the sideband shift is equal to the spatial frequency of the standing-wave (SW) field, more complete recovery of information is possible by superposition of fields having different periods. When all of the fields have an antinode at a common plane (set to be coincident with the in-focus plane), the "synthesized" field is peaked in a narrow infocus zone.


Author(s):  
E. Silva ◽  
R. Scozia

The purpose in obtaining zone axis pattern map (zap map) from a given material is to provide a quick and reliable tool to identify cristaline phases, and crystallographic directions, even in small particles. Bend contours patterns and Kossel lines patterns maps from Zr single crystal in the [0001] direction have been presented previously. In the present communication convergent beam electron diffraction (CBED) zap map of Zr will be shown. CBED patterns were obtained using a Philips microscope model EM300, which was set up to carry out this technique. Convergent objective upper pole piece for STEM and some electronic modifications in the lens circuits were required, furthermore the microscope was carefully cleaned and it was operated at a vacuum eminently good.CBED patterns in the Zr zap map consist of zero layer disks, showing fine details within them which correspond to intersecting set of higher order Laue zone (HOLZ) deficiency lines.


Author(s):  
Dong Yuming ◽  
Yang Guanglin ◽  
Du Wei Dong ◽  
Xu Ai Liam

The activities and distributions of AKPase ,ACPase,G6Pase,TPPase and COase in human normal gastric mucosa and gastric cancer tissues were studied histochemically at light microscopic level. These enzymes are the marker enzymes of cell membrane lysosome endoplasmic reticulum, Golgi apparatus and mitochondrion objectively. On the basis of the research we set up a special ultrastructural cytochemical technique and first researched into gastric cancer domesticly. Ultrastructural cytochemistry is also called electron microscopic cytochemistry. This new technique possesses both the sensitivity of cytochemical reaction andi the high resolution of electron microscope. It is characterized by direct observation,exact localization and the combination morphology with function.The distributions of AKPase,ACPase,G6Pase,TPPase and COase in 14 cases of gastric cancer and 1 case of gastric Denign lesion were studied ultrastructurally. The results showed: 1. normal gastric epithelium had no AKPase reaction. The reaction of ACPase,G6Pase,TPPase and Coase were found in the corresponding organella, which were consistent with their function.


2016 ◽  
Vol 75 (3) ◽  
pp. 123-132 ◽  
Author(s):  
Marie Crouzevialle ◽  
Fabrizio Butera

Abstract. Performance-approach goals (i.e., the desire to outperform others) have been found to be positive predictors of test performance, but research has also revealed that they predict surface learning strategies. The present research investigates whether the high academic performance of students who strongly adopt performance-approach goals stems from test anticipation and preparation, which most educational settings render possible since examinations are often scheduled in advance. We set up a longitudinal design for an experiment conducted in high-school classrooms within the context of two science, technology, engineering, and mathematics (STEM) disciplines, namely, physics and chemistry. First, we measured performance-approach goals. Then we asked students to take a test that had either been announced a week in advance (enabling strategic preparation) or not. The expected interaction between performance-approach goal endorsement and test anticipation was moderated by the students’ initial level: The interaction appeared only among low achievers for whom the pursuit of performance-approach goals predicted greater performance – but only when the test had been scheduled. Conversely, high achievers appeared to have adopted a regular and steady process of course content learning whatever their normative goal endorsement. This suggests that normative strivings differentially influence the study strategies of low and high achievers.


Sign in / Sign up

Export Citation Format

Share Document