S-nitroso human serum albumin given after LPS challenge reduces acute lung injury and prolongs survival in a rat model of endotoxemia

2008 ◽  
Vol 379 (3) ◽  
pp. 281-290 ◽  
Author(s):  
A. Jakubowski ◽  
N. Maksimovich ◽  
R. Olszanecki ◽  
A. Gebska ◽  
H. Gasser ◽  
...  
2007 ◽  
Vol 103 (1) ◽  
pp. 28-38 ◽  
Author(s):  
Vibhudutta Awasthi ◽  
Seong-Hwan Yee ◽  
Paul Jerabek ◽  
Beth Goins ◽  
William T. Phillips

Liposome-encapsulated Hb (LEH) is being developed as an artificially assembled, low-toxicity, and spatially isolated Hb-based oxygen carrier (HBOC). Standard methods of evaluating oxygen carriers are based on surrogate indicators of physiology in animal models of shock. Assessment of actual delivery of oxygen by HBOCs and resultant improvement in oxygen metabolism at the tissue level has been a technical challenge. In this work, we report our findings from 15O-positron emission tomographic (15O-PET) evaluation of LEH in a rat model of 40% hypovolemic shock. In vitro studies showed that PEGylated LEH formulation containing ∼7.5% Hb and consisting of neutral lipids (distearoylphosphatidylcholine:cholesterol:α-tocopherol, 51.4:46.4:2.2) efficiently picks up 15O-labeled oxygen gas. The final preparation of LEH contained 5% human serum albumin to provide oncotic pressure. Cerebral PET images of anesthetized rats inhaling 15O-labeled O2 gas showed efficient oxygen-carrying and delivery capacity of LEH formulation. From the PET images, we determined cerebral metabolic rate of oxygen (CMRO2) as a direct indicator of oxygen-carrying capacity of LEH as well as oxygen delivery and metabolism in rat brain. Compared with control fluids [saline and 5% human serum albumin (HSA)], LEH significantly improved CMR[Formula: see text] to ∼80% of baseline level. Saline and HSA resuscitation could not improve hypovolemia-induced decrease in CMR[Formula: see text]. On the other hand, resuscitation of shed blood was the most efficient in restoring oxygen metabolism. The results suggest that 15O-PET technology can be successfully employed to evaluate potential oxygen carriers and blood substitutes and that LEH resuscitation in hemorrhage enhances oxygen delivery to the cerebral tissue and improves oxygen metabolism in brain.


2011 ◽  
Vol 154 (2) ◽  
pp. 189-195 ◽  
Author(s):  
Masato Furukawa ◽  
Ryota Tanaka ◽  
Victor Tuan Giam Chuang ◽  
Yu Ishima ◽  
Kazuaki Taguchi ◽  
...  

1969 ◽  
Vol 08 (01) ◽  
pp. 15-21 ◽  
Author(s):  
K. E. Scheer ◽  
J. Heep ◽  
W. Maier-Borst ◽  
W. J. Lorenz ◽  
H. Sinn ◽  
...  

ZusammenfassungNach tierexperimentellen Voruntersuchungen wurde die Placentographie mit trägerfreiem 113Inm -HSA als klinische Methode eingeführt. Vor Amniocentesen und bei Verdacht auf Placenta praevia werden Placentographien geschrieben. Den Schwangeren wird eine Aktivität von 500 μCi in die Cubitalvene injiziert. Die der Aktivität entsprechende Indiummenge ist kleiner als 0,1 ng. Die fetale Strahlenbelastung liegt unter lOmrad. Bei Anwendung von 113Inm-HSA entfällt eine Blockade der mütterlichen und fetalen Schilddrüsen. Die genaue Abgrenzung einer Placenta praevia wird nicht durch eine Blasenaktivität beeinträchtigt.Es wurden bisher 19 Placentalokalisationen durchgeführt. In allen Fällen konnte der Placentasitz eindeutig festgestellt werden. Bedingt durch die lange Liegezeit beim Aufnehmen eines Szintigramms kam es in zwei Fällen zu einem Vena-Cava-Kompressions-Syndrom. Zur Verhinderung dieser klinischen Zwischenfälle werden inzwischen Placentographien mit der Anger-Kamera aufgenommen. Mit Hilfe des divergierenden Kollimators konnte der gesamte Abdominalbereich erfaßt werden. Die Aufnahmezeit konnte auf 7 — 10 Minuten verkürzt werden. Die intravenöse injizierte Aktivität betrug bei dieser Methode ebenfalls 500 μCi. Der diagnostische Aussagewert der Kamerabilder ist szintigraphischen Aufnahmen gleichwertig.


Sign in / Sign up

Export Citation Format

Share Document