Post-Biopsy Manoeuvres to Reduce Pneumothorax Incidence in CT-Guided Transthoracic Lung Biopsies: A Systematic Review and Meta-analysis

2019 ◽  
Vol 42 (8) ◽  
pp. 1062-1072 ◽  
Author(s):  
Ya Ruth Huo ◽  
Michael Vinchill Chan ◽  
Al-Rahim Habib ◽  
Isaac Lui ◽  
Lloyd Ridley
2020 ◽  
Vol 93 (1108) ◽  
pp. 20190866 ◽  
Author(s):  
Ya Ruth Huo ◽  
Michael Vinchill Chan ◽  
Al-Rahim Habib ◽  
Isaac Lui ◽  
Lloyd Ridley

Objective: This systematic review and meta-analysis investigated risk factors for pneumothorax following CT-guided percutaneous transthoracic lung biopsy. Methods: A systematic search of nine literature databases between inception to September 2019 for eligible studies was performed. Results: 36 articles were included with 23,104 patients. The overall pooled incidence for pneumothorax was 25.9% and chest drain insertion was 6.9%. Pneumothorax risk was significantly reduced in the lateral decubitus position where the biopsied lung was dependent compared to a prone or supine position [odds ratio (OR):3.15]. In contrast, pneumothorax rates were significantly increased in the lateral decubitus position where the biopsied lung was non-dependent compared to supine (OR:2.28) or prone position (OR:3.20). Other risk factors for pneumothorax included puncture site up compared to down through a purpose-built biopsy window in the CT table (OR:4.79), larger calibre guide/needles (≤18G vs >18G: OR 1.55), fissure crossed (OR:3.75), bulla crossed (OR:6.13), multiple pleural punctures (>1 vs 1: OR:2.43), multiple non-coaxial tissue sample (>1 vs 1: OR 1.99), emphysematous lungs (OR:3.33), smaller lesions (<4 cm vs 4 cm: OR:2.09), lesions without pleural contact (OR:1.73) and deeper lesions (≥3 cm vs <3cm: OR:2.38). Conclusion: This meta-analysis quantifies factors that alter pneumothorax rates, particularly with patient positioning, when planning and performing a CT-guided lung biopsy to reduce pneumothorax rates. Advances in knowledge: Positioning patients in lateral decubitus with the biopsied lung dependent, puncture site down with a biopsy window in the CT table, using smaller calibre needles and using coaxial technique if multiple samples are needed are associated with a reduced incidence of pneumothorax.


2021 ◽  
pp. neurintsurg-2021-017419
Author(s):  
Giorgos D Michalopoulos ◽  
Yagiz Ugur Yolcu ◽  
Abdul Karim Ghaith ◽  
Mohammed Ali Alvi ◽  
Carrie M Carr ◽  
...  

BackgroundCT-guided biopsy is a commonly used diagnostic procedure for spinal lesions. This meta-analysis aims to investigate its diagnostic performance and complications, as well as factors influencing outcomes.MethodsA systematic review of the literature was performed to identify studies reporting outcomes of CT-guided biopsies for spinal lesions. Diagnostic yield (ie, the rate of procedures resulting in a specific pathological diagnosis) and diagnostic accuracy (ie, the rate of procedures resulting in the correct diagnosis) were the primary outcomes of interest. Complications following biopsy procedures were also included.ResultsThirty-nine studies with 3917 patients undergoing 4181 procedures were included. Diagnostic yield per procedure was 91% (95% CI 88% to 94%) among 3598 procedures. The most common reason for non-diagnostic biopsies was inadequacy of sample. No difference in diagnostic yield between different locations and between lytic, sclerotic, and mixed lesions was found. Diagnostic yield did not differ between procedures using ≤13G and ≥14G needles. Diagnostic accuracy per procedure was 86% (95% CI 82% to 89%) among 3054 procedures. Diagnostic accuracy among 2426 procedures that yielded a diagnosis was 94% (95% CI 92% to 96%). Complication rate was 1% (95% CI 0.4% to 1.9%) among 3357 procedures. Transient pain and minor hematoma were the most common complications encountered.ConclusionIn our meta-analysis of 39 studies reporting diagnostic performance and complications of CT-guided biopsy, we found a diagnostic yield of 91% and diagnostic accuracy of 86% with a complication rate of 1%. Diagnostic yield did not differ between different locations, between lytic, sclerotic and mixed lesions, and between wide- and thin-bore needles.


Author(s):  
Ahmad M. Tarawneh ◽  
Shahnawaz Haleem ◽  
Daniel D’Aquino ◽  
Nasir Quraishi

OBJECTIVE The goal of this study was to evaluate the comparative accuracy and safety of navigation-based approaches for cervical pedicle screw (CPS) placement over fluoroscopic techniques. METHODS A systematic search of the literature published between January 2006 and December 2019 relating to CPS instrumentation and the comparative accuracy and safety of fluoroscopic and intraoperative computer-based navigation techniques was conducted. Several databases, including the Cochrane Library, PubMed, and EMBASE, were systematically searched to identify potentially eligible studies. Data relating to CPS insertion accuracy and associated complications, in particular neurovascular complications, were extrapolated from the included studies and summarized for analysis. RESULTS A total of 17 studies were identified from the search methodology. Eleven studies evaluated CPS placement under traditional fluoroscopic guidance and 6 studies addressed outcomes following navigation-assisted placement (3D C-arm or CT-guided placement). Overall, a total of 4278 screws were placed in 1065 patients. Misplacement rates of CPS were significantly lower (p < 0.0001) in navigation-assisted techniques (12.51% [range 2.5%–20.5%]) compared to fluoroscopy-guided techniques (18.8% [range 0%–43.5%]). Fluoroscopy-guided CPS insertion was associated with a significantly higher incidence of postoperative complications relating to neurovascular injuries (p < 0.038), with a mean incidence of 1.9% compared with 0.3% in navigation-assisted techniques. CONCLUSIONS This systematic review supports a logical conclusion that navigation-based techniques confer a statistically significantly more accurate screw placement and resultant lower complication rates.


Respiration ◽  
2020 ◽  
pp. 1-11
Author(s):  
Federico Mei ◽  
Martina Bonifazi ◽  
Matteo Rota ◽  
Laura Cirilli ◽  
Martina Grilli ◽  
...  

<b><i>Background:</i></b> Diagnostic yield (DY) and safety of computed tomography (CT)- and thoracic ultrasound (TUS)-guided biopsies in the diagnosis of pleural lesions have been investigated in a number of studies, but no synthesis of data from the literature has ever been performed. <b><i>Objectives:</i></b> We aimed to provide the first systematic review and meta-analysis on the DY and safety of CT- versus TUS-guided biopsy in the diagnosis of pleural lesions. <b><i>Method:</i></b> We searched MEDLINE and EMBASE for all studies reporting outcomes of interest published up to April 2018. Two authors reviewed all titles/abstracts and retrieved selected full text to identify studies according to predefined selection criteria. Summary estimates were derived using the random-effects model. Cumulative meta-analysis assessed the influence of increasing adoption of the procedures over time. <b><i>Results:</i></b> Thirty original studies were included in the present review; the number of studies on TUS-guided biopsy was almost three-fold higher than those on CT-guided biopsy. The pooled DYs of the 2 procedures were overall excellent and differed &#x3c;10%, being 84% for TUS-guided biopsy and 93% for CT-guided biopsy. Safety profiles were reassuring for both the techniques, being 7 and 3% for CT- and TUS-guided biopsy, respectively. DY of ultrasound technique significantly improved over time, while no time effect was observed for CT-guided biopsy. <b><i>Conclusions:</i></b> Data show that CT- and TUS-guided biopsies in the diagnosis of pleural lesions are both excellent procedures, without meaningful differences in DYs and safety. Considering that TUS is non-ionizing and easily performed at the bedside, it should be the preferred approach in presence of adequate skills.


Sign in / Sign up

Export Citation Format

Share Document