scholarly journals Is body weight the most appropriate criterion to select patients eligible for low-dose pulmonary CT angiography? Analysis of objective and subjective image quality at 80 kVp in 100 patients

2009 ◽  
Vol 19 (8) ◽  
pp. 1914-1922 ◽  
Author(s):  
Zsolt Szucs-Farkas ◽  
Tamara Strautz ◽  
Michael A. Patak ◽  
Luzia Kurmann ◽  
Peter Vock ◽  
...  
2021 ◽  
Vol 94 (1117) ◽  
pp. 20200677
Author(s):  
Andrea Steuwe ◽  
Marie Weber ◽  
Oliver Thomas Bethge ◽  
Christin Rademacher ◽  
Matthias Boschheidgen ◽  
...  

Objectives: Modern reconstruction and post-processing software aims at reducing image noise in CT images, potentially allowing for a reduction of the employed radiation exposure. This study aimed at assessing the influence of a novel deep-learning based software on the subjective and objective image quality compared to two traditional methods [filtered back-projection (FBP), iterative reconstruction (IR)]. Methods: In this institutional review board-approved retrospective study, abdominal low-dose CT images of 27 patients (mean age 38 ± 12 years, volumetric CT dose index 2.9 ± 1.8 mGy) were reconstructed with IR, FBP and, furthermore, post-processed using a novel software. For the three reconstructions, qualitative and quantitative image quality was evaluated by means of CT numbers, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in six different ROIs. Additionally, the reconstructions were compared using SNR, peak SNR, root mean square error and mean absolute error to assess structural differences. Results: On average, CT numbers varied within 1 Hounsfield unit (HU) for the three assessed methods in the assessed ROIs. In soft tissue, image noise was up to 42% lower compared to FBP and up to 27% lower to IR when applying the novel software. Consequently, SNR and CNR were highest with the novel software. For both IR and the novel software, subjective image quality was equal but higher than the image quality of FBP-images. Conclusion: The assessed software reduces image noise while maintaining image information, even in comparison to IR, allowing for a potential dose reduction of approximately 20% in abdominal CT imaging. Advances in knowledge: The assessed software reduces image noise by up to 27% compared to IR and 48% compared to FBP while maintaining the image information. The reduced image noise allows for a potential dose reduction of approximately 20% in abdominal imaging.


2009 ◽  
Vol 20 (5) ◽  
pp. 1197-1206 ◽  
Author(s):  
Tobias Pflederer ◽  
Josy Jakstat ◽  
Mohamed Marwan ◽  
Tiziano Schepis ◽  
Sven Bachmann ◽  
...  

2016 ◽  
Vol 71 (1) ◽  
pp. 64-73 ◽  
Author(s):  
W.H. Nijhof ◽  
E.J.M. Baltussen ◽  
I.M.J. Kant ◽  
G.J. Jager ◽  
C.H. Slump ◽  
...  

2021 ◽  
Vol 76 (2) ◽  
pp. 156.e19-156.e26
Author(s):  
S. Park ◽  
S.H. Park ◽  
J.H. Hwang ◽  
J.H. Kim ◽  
K.H. Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document