A distributed lumped parameter model of blood flow with fluid-structure interaction

Author(s):  
Ryan Pewowaruk ◽  
Alejandro Roldán-Alzate
Perfusion ◽  
2021 ◽  
pp. 026765912199854
Author(s):  
Mohammad Javad Ghasemi Pour ◽  
Kamran Hassani ◽  
Morteza Khayat ◽  
Shahram Etemadi Haghighi

Background and objectives: Fluid structure interaction (FSI) is defined as interaction of the structures with contacting fluids. The aortic valve experiences the interaction with blood flow in systolic phase. In this study, we have tried to predict the hemodynamics of blood flow through a normal and stenotic aortic valve in two relaxation and exercise conditions using a three-dimensional FSI method. Methods: The aorta valve was modeled as a three-dimensional geometry including a normal model and two others with 25% and 50% stenosis. The geometry of the aortic valve was extracted from CT images and the models were generated by MMIMCS software and then they were implemented in ANSYS software. The pulsatile flow rate was used for all cases and the numerical simulations were conducted based on a time-dependent domain. Results: The obtained results including the velocity, pressure, and shear stress contours in different systolic time sequences were explained and discussed. The maximum blood flow velocity in relaxation phase was obtained 1.62 m/s (normal valve), 3.78 m/s (25% stenosed valve), and 4.73 m/s (50% stenosed valve). In exercise condition, the maximum velocities are 2.86, 4.32, and 5.42 m/s respectively. The maximum blood pressure in relaxation phase was calculated 111.45 mmHg (normal), 148.66 mmHg (25% stenosed), and 164.21 mmHg (50% stenosed). However, the calculated values in exercise situation were 129.57, 163.58, and 191.26 mmHg. The validation of the predicted results was also conducted using existing literature. Conclusions: We believe that such model are useful tools for biomechanical experts. The further studies should be done using experimental data and the data are implemented on the boundary conditions for better comparison of the results.


2021 ◽  
Vol 11 (2) ◽  
pp. 13-16
Author(s):  
Artur Ovsepyan ◽  
Alexander Smirnov ◽  
Sergey Dydykin ◽  
Yuriy Vasil'ev ◽  
Evgeniy Trunin ◽  
...  

The interaction of the blood flow with the aorta is a complex dynamic event described in biomechanics as the Fluid-structure interaction. In this study we’ve developed a method for creation of a personalized 3D dynamic model of the aortic bulb and arch for the prediction of its mechanical behavior using FSI-analysis. We found that the accuracy of predicting geometric aortic deformities based on FSI modeling is on average 92%.


Author(s):  
Ahmad Moghaddaszade-Kermani ◽  
Peter Oshkai ◽  
Afzal Suleman

Mitral-Septal contact has been proven to be the cause of obstruction in the left ventricle with hypertrophic cardiomyopathy (HC). This paper presents a study on the fluid mechanics of obstruction using two-way loosely coupled fluid-structure interaction (FSI) methodology. A parametric model for the geometry of the diseased left ventricular cavity, myocardium and mitral valve has been developed, using the dimensions extracted from magnetic resonance images. The three-element Windkessel model [1] was modified for HC and solved to introduce pressure boundary condition to the aortic aperture in the systolic phase. The FSI algorithm starts at the beginning of systolic phase by applying the left ventricular pressure to the internal surface of the myocardium to contract the muscle. The displacements of the myocardium and mitral leaflets were calculated using the nonlinear finite element hyperelastic model [2] and subsequently transferred to the fluid domain. The fluid mesh was moved accordingly and the Navier-Stokes equations were solved in the laminar regime with the new mesh using the finite volume method. In the next time step, the left ventricular pressure was increased to contract the muscle further and the same procedure was repeated for the fluid solution. The results show that blood flow jet applies a drag force to the mitral leaflets which in turn causes the leaflet to deform toward the septum thus creating a narrow passage and possible obstruction.


Author(s):  
Megan Laughlin ◽  
Sam Stephens ◽  
Hanna Jensen ◽  
Morten Jensen ◽  
Paul Millett

Abstract Fluid Structure Interaction (FSI) models are an essential tool in understanding the complex coupling of blood flow in the heart. The objective of this study is to establish a method of comparing data obtained from FSI models and benchtop measurements from phantoms to identify sources of flow changes for use in intraventricular flow analysis. Two geometries are considered: 1) a vascular model consisting of a straight channel with an ellipsoidal swell and 2) an idealized left ventricle (LV) model representative “acorn” shape. Two phantoms are created for each of the two geometries: 3D printed rigid phantoms from a resin and custom-made tissue-mimicking phantoms from a medical gel. Benchtop measurements are made using the phantoms within a custom flow loop setup with pulsatile flow. Computational Fluid Dynamics (CFD) simulations are conducted with a Smoothed Particle Hydrodynamics (SPH) model. The two flow channel geometries utilized in the experiments are replicated for the simulations. The cavity walls are defined by ghost particles that are rigidly fixed. Maximum pressure drops were 57 mmHg and 196 mmHg for the rigid swell and rigid LV, respectively, whereas maximum pressure drops were 155 mmHg for the gel swell and 140 mmHg for the gel LV. Calculations from the simulations resulted in a maximum pressure drop of 55 mmHg for the swell and 110 mmHg for the LV. This data serves as a first step in corroborating our methodology to utilize the information obtained from both methods to identify and better understand mutual sources of changes in flow patterns.