Sensitive detection of uranium in water samples using differential pulse adsorptive stripping voltammetry on glassy carbon electrode

2019 ◽  
Vol 322 (3) ◽  
pp. 2049-2056 ◽  
Author(s):  
Zhiping Zhou ◽  
Yueming Zhou ◽  
Xizhen Liang ◽  
Fang Xie ◽  
Shujuan Liu ◽  
...  
The Analyst ◽  
2016 ◽  
Vol 141 (10) ◽  
pp. 2904-2910 ◽  
Author(s):  
Madalena C. C. Areias ◽  
Kenichi Shimizu ◽  
Richard G. Compton

High sensitive detection of glutathione in presence of copper(ii) ions by cyclic voltammetry using a bare glassy carbon electrode is presented.


2019 ◽  
Vol 63 (1) ◽  
Author(s):  
Mehdi Jalali ◽  
Zeinab Deris Falahieh ◽  
Mohammad Alimoradi ◽  
Jalal Albadi ◽  
Ali Niazi

The electrochemical behavior of Bi+3 ions on the surface of a glassy carbon electrode, in acidic media and in the presence of tamoxifen, was investigated. Cyclic voltammetry, chronoamperometry, differential pulse voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy with energy-dispersive X-ray spectroscopy were used to find the probable mechanism contributing to the reduction of the peak height of bismuth oxidation with an increase in the concentration of tamoxifen. The obtained results show a slight interaction between the bismuth species and tamoxifen which co-deposit on the surface of glassy carbon electrode. Therefore, the reduction in the peak height of bismuth oxidation as a function of tamoxifen concentration was used to develop a new differential pulse anodic striping voltammetry method for determination of trace amount of tamoxifen. The effects of experimental parameters on the in situ DPASV of Bi+3 ions in the presence of tamoxifen shown the optimal conditions as: 2 mol L-1 H2SO4 (1% v v-1 MeOH), a deposition potential of -0.5 V, a deposition time of 60 s, and a glassy carbon electrode rotation rate of 300 rpm. The calibration curve was plotted in the range of 0.5 to 6 µg mL-1 and the limits of detection and quantitation were calculated to be 3.1 × 10-5 µg mL-1 and 1.0 × 10-4 µg mL-1, respectively. The mean, RSD, and relative bias for 0.5 µg mL-1 (n=5) were found to be 0.49 µg mL-1, 0.3%, and 2%, respectively. Finally, the proposed method was successfully used for the determination of tamoxifen in serum and pharmaceutical samples.


2018 ◽  
Vol 4 (5) ◽  
pp. 567-571
Author(s):  
Aaron Mary Ratna Sylvia ◽  
C. Vedhi ◽  
A. Gomathi

The voltammetric behaviour of 4-nitroso-N,N–dimethylaniline (4-NDMA) was investigated on plain glassy carbon electrode (GCE) and multi-walled carbon nanotube modified GCE (MWCNT/GCE) using cyclic voltammetry. Effects of pH, scan rate and concentration were studied. The surface morphology of the modified electrode in the absence and presence of 4-NDMA molecules was characterized by atomic force microscope (AFM). A systematic study on the variation of experimental parameters with differential pulse stripping voltammetry (DPSV) was carried out and the optimized experimental conditions were arrived. MWCNT/GCE performed well compared with the plain GCE system and the limit of detection (LOD) was found to be 7.5 ng/mL 0.1056 ng/mL for 4-NDMA on plain GCE and MWCNT/GCE respectively.