High-performance liquid chromatographic method for stability and pharmacokinetic studies of nicorandil

Author(s):  
Elizabeth L. Bachert ◽  
Ho-Leung Fung
2016 ◽  
Vol 5 (12) ◽  
pp. 5151
Author(s):  
Sivannarayana P.* ◽  
K. Rambabu

A new reverse phase-high performance liquid chromatographic method for the assay of mupirocin and metronidazole in formulation has been developed and validated as per ICH guidelines. The present study was carried on Water’s X-bridge C-18 column (4.6 x150mm, 5μ particle size) with mobile phase containing a mixture phosphate buffer (pH 2.5) and acetonitrile in the ratio of 70:30, %v/v at a flow rate of 1.0ml/min with UV detection at 220nm in ambient column temperature. The retention times for mupirocin and metronidazole were found to be 2.153 and 3.157 min respectively with linearity in the concentration range of 20-60μg/mL for mupirocin and 10-30μg/mL for metronidazole respectively. The developed reverse phase-high performance liquid chromatographic method was found to be best suitable for pharmacokinetic studies of these mentioned drugs in formulations.


Author(s):  
Payyavula Venkata Rao ◽  
Rambabu C

ABSTRACTObjective: The present aim is to develop simple, precise, and accurate reverse phase high performance liquid chromatographic method (RP-HPLC) forthe simultaneous assay of artemether and lumefantrine in fixed combined dosage form.Methods: The chromatographic study was carried out on Hypersil C18 column (250×4.6 mm, 5 μ) with mobile phase containing a mixture of KH2PO4buffer (pH-3.5) and acetonitrile in the ratio of 45:55% v/v at a flow rate of 1.0 ml/minute with ultraviolet detection at 218 nm in ambient columntemperature.Results: Using the optimized chromatographic conditions artemether and lumefantrine eluted with retention times of 2.207 and 3.733 minutes,respectively. The method was validated according to ICH guidelines with good reproducibility and linear responses, y=60.813.x+629.53 (r²=0.9982)for artemether and y=88.3108.x+2370.2 (r²=0.9912). The % relative standard deviations of intra-day precision was ranged 0.378% and 1.26% forartemether and 0.459% and 1.15% for lumefantrine, respectively. The percentage recoveries were ranged from 99.96% to 100.02% for artemetherand 99.96-99.97% for lumefantrine, respectively.Conclusions: The developed RP-HPLC method was validated as per ICH guidelines and was found to be best suitable for pharmacokinetic studies ofthese mentioned drugs.Keywords: Artemether, Lumefantrine, ICH guidelines.


Sign in / Sign up

Export Citation Format

Share Document