Two phase flow heat transfer analysis at different flow patterns in the wellbore

2017 ◽  
Vol 117 ◽  
pp. 544-552 ◽  
Author(s):  
Yonghai Gao ◽  
Yanchun Cui ◽  
Boyue Xu ◽  
Baojiang Sun ◽  
Xinxin Zhao ◽  
...  
2021 ◽  
Vol 79 (9) ◽  
pp. 656-680
Author(s):  
Yun Liu ◽  
Zhigang Li ◽  
Yuyan Jiang ◽  
Cong Guo ◽  
Dawei Tang

Author(s):  
Weilin Qu ◽  
Seok-Mann Yoon ◽  
Issam Mudawar

Knowledge of flow pattern and flow pattern transitions is essential to the development of reliable predictive tools for pressure drop and heat transfer in two-phase micro-channel heat sinks. In the present study, experiments were conducted with adiabatic nitrogen-water two-phase flow in a rectangular micro-channel having a 0.406 × 2.032 mm cross-section. Superficial velocities of nitrogen and water ranged from 0.08 to 81.92 m/s and 0.04 to 10.24 m/s, respectively. Flow patterns were first identified using high-speed video imaging, and still photos were then taken for representative patterns. Results reveal that the dominant flow patterns are slug and annular, with bubbly flow occurring only occasionally; stratified and churn flow were never observed. A flow pattern map was constructed and compared with previous maps and predictions of flow pattern transition models. Annual flow is identified as the dominant flow pattern for conditions relevant to two-phase micro-channel heat sinks, and forms the basis for development of a theoretical model for both pressure drop and heat transfer in micro-channels. Features unique to two-phase micro-channel flow, such as laminar liquid and gas flows, smooth liquid-gas interface, and strong entrainment and deposition effects are incorporated into the model. The model shows good agreement with experimental data for water-cooled heat sinks.


2008 ◽  
Vol 131 (1) ◽  
Author(s):  
Jong Chull Jo ◽  
Woong Sik Kim ◽  
Chang-Yong Choi ◽  
Yong Kab Lee

This paper addresses the numerical simulation of two-phase flow heat transfer in the helically coiled tubes of an integral type pressurized water reactor steam generator under normal operation using a computational fluid dynamics code. The shell-side flow field where a single-phase fluid flows in the downward direction is also calculated in conjunction with the tube-side two-phase flow characteristics. For the calculation of tube-side two-phase flow, the inhomogeneous two-fluid model is used. Both the Rensselaer Polytechnic Institute wall boiling model and the bulk boiling model are implemented for the numerical simulations of boiling-induced two-phase flow in a vertical straight pipe and channel, and the computed results are compared with the available measured data. The conjugate heat transfer analysis method is employed to calculate the conduction in the tube wall with finite thickness and the convections in the internal and external fluids simultaneously so as to match the fluid-wall-fluid interface conditions properly. Both the internal and external turbulent flows are simulated using the standard k-ε model. From the results of the present numerical simulation, it is shown that the bulk boiling model can be applied to the simulation of two-phase flow in the helically coiled steam generator tubes. In addition, the present simulation method is considered to be physically plausible in the light of discussions on the computed results.


Author(s):  
Jong Chull Jo ◽  
Woong Sik Kim ◽  
Chang-Yong Choi ◽  
Yong Kab Lee

This paper addresses the numerical simulation of two phase flow heat transfer in the helically coiled tubes of an integral type pressurized water reactor steam generator under normal operation using a CFD code. The single phase flow which flow downward direction in the shell side is also calculated together. For the calculation of tube side two-phase flow the inhomogeneous two-fluid model is used. Both the RPI (Rensselaer Polytechnic Institute) wall boiling model and the bulk boiling model are implemented for the numerical simulation and the computed results are compared with the available measured data. The conjugate heat transfer analysis method is employed to calculate the conduction in the tube wall with finite thickness and the convections in the internal and external fluids simultaneously so as to match the fluid-wall-fluid interface conditions properly. Both the internal and external turbulent flows are simulated using the standard k-ε model From the results of present numerical simulation, it is shown that the bulk boiling model can be applied to the simulation of two-phase flow in the helically coiled steam generator tubes. The results also show that the present simulation method is considered to be physically plausible when the computed results are compared with available previous experimental and numerical studies.


2004 ◽  
Vol 126 (3) ◽  
pp. 288-300 ◽  
Author(s):  
Weilin Qu ◽  
Seok-Mann Yoon ◽  
Issam Mudawar

Knowledge of flow pattern and flow pattern transitions is essential to the development of reliable predictive tools for pressure drop and heat transfer in two-phase micro-channel heat sinks. In the present study, experiments were conducted with adiabatic nitrogen-water two-phase flow in a rectangular micro-channel having a 0.406×2.032mm2 cross-section. Superficial velocities of nitrogen and water ranged from 0.08 to 81.92 m/s and 0.04 to 10.24 m/s, respectively. Flow patterns were first identified using high-speed video imaging, and still photos were then taken for representative patterns. Results reveal the dominant flow patterns are slug and annular, with bubbly flow occurring only occasionally; stratified and churn flow were never observed. A flow pattern map was constructed and compared with previous maps and predictions of flow pattern transition models. Features unique to two-phase micro-channel flow were identified and employed to validate key assumptions of an annular flow boiling model that was previously developed to predict pressure drop and heat transfer in two-phase micro-channel heat sinks. This earlier model was modified based on new findings from the adiabatic two-phase flow study. The modified model shows good agreement with experimental data for water-cooled heat sinks.


2009 ◽  
Vol 132 (1) ◽  
Author(s):  
Michael Flouros

Advanced aircraft engine development dictates high standards of reliability for the lubrication systems, not only in terms of the proper lubrication of the bearings and the gears, but also in terms of the removal of the large amounts of the generated heat. Heat is introduced both internally through the rotating hardware and externally through radiation, conduction, and convection. In case where the bearing chamber is in close proximity to the engine’s hot section, the external heat flux may be significant. This is, for example, the case when oil pipes pass through the turbine struts and vanes on their way to the bearing chamber. There, the thermal impact is extremely high, not only because of the hot turbine gases flowing around the vanes, but also because of the hot cooling air, which is ingested into the vanes. The impact of this excessive heat on the oil may lead to severe engine safety and reliability problems, which can range from oil coking with blockage of the oil tubes to oil fires with loss of part integrity, damage, or even failure of the engine. It is therefore of great importance that the oil system designer is capable of predicting the system’s functionality. As part of the European Research program efficient and environmentally friendly aero-engine, the project component validator for environmentally friendly aero-engine (Wilfert, et al., 2005, “CLEAN–Validation of a GTF High Speed Turbine and Integration of Heat Exchanger Technology in an Environmental Friendly Engine Concept,” International Symposium on Air Breathing Engines, Paper No. ISABE-2005-1156;Gerlach et al., 2005, “CLEAN–Bench Adaptation and Test for a Complex Demo Engine Concept at ILA Stuttgart,” International Symposium on Air Breathing Engines, Paper No. ISABE-2005-1134) was initiated with the goal to develop future engine technologies. Within the scope of this program, MTU Aero Engines has designed the lubrication system and has initiated an investigation of the heat transfer in the scavenge and vent tubes passing through the high thermally loaded turbine center frame (TCF). The objective was to evaluate analytical and numerical models for the heat transfer into the air and oil mixtures and benchmark them. Three analytical models were investigated. A model that was based on the assumption that the flow of air and oil is a homogeneous mixture, which was applied on the scavenge flow. The other two models assumed annular two-phase flows and were applied on the vent flows. Additionally, the two-phase flow in the scavenge and vent pipes was simulated numerically using the ANSYS CFX package. The evaluation of the models was accomplished with test data from the heavily instrumented test engine with special emphasis on the TCF. Both the analytical and the numerical models have demonstrated strengths and weaknesses. The homogeneous flow model correlation and the most recent correlation by Busam for vent flows have demonstrated very good agreement between test and computed results. On the other hand the numerical analysis produced remarkable results, however, at the expense of significant modeling and computing efforts. This particular work is unique compared with published investigations since it was conducted in a real engine environment and not in a simulating rig. Nevertheless, research in two-phase flow heat transfer will continue in order to mitigate any deficiencies and to further improve the correlations and the CFD tools.