scholarly journals Deformation pattern and load transfer of an uncemented femoral stem with modular necks. An experimental study in human cadaver femurs

2016 ◽  
Vol 32 ◽  
pp. 28-33 ◽  
Author(s):  
Cathrine H. Enoksen ◽  
Nils R. Gjerdet ◽  
Jomar Klaksvik ◽  
Astvaldur J. Arthursson ◽  
Otto Schnell-Husby ◽  
...  
2014 ◽  
Vol 29 (3) ◽  
pp. 330-335 ◽  
Author(s):  
Cathrine H. Enoksen ◽  
Nils R. Gjerdet ◽  
Jomar Klaksvik ◽  
Astvaldur J. Arthursson ◽  
Otto Schnell-Husby ◽  
...  

2012 ◽  
Vol 594-597 ◽  
pp. 527-531
Author(s):  
Wan Qing Zhou ◽  
Shun Pei Ouyang

Based on the experimental study of rotary filling piles with large diameter subjected to axial load in deep soft soil, the bearing capacity behavior and load transfer mechanism were discussed. Results show that in deep soft soil foundation, the super–long piles behave as end-bearing frictional piles. The exertion of the shaft resistance is not synchronized. The upper layer of soil is exerted prior to the lower part of soil. Meanwhile, the exertion of shaft resistance is prior to the tip resistance. For the different soil and the different depth of the same layer of soil, shaft resistance is different.


2016 ◽  
Vol 13 (4) ◽  
pp. 322-326 ◽  
Author(s):  
Munnan Al-Najjim ◽  
Usman Khattak ◽  
Juluis Sim ◽  
Iain Chambers

2009 ◽  
Vol 131 (4) ◽  
Author(s):  
A. Herrera ◽  
J. J. Panisello ◽  
E. Ibarz ◽  
J. Cegoñino ◽  
J. A. Puértolas ◽  
...  

The implantation of a cemented or cementless femoral stem changes the physiological load transfer on the femur producing an effect on the bone called adaptative remodeling. The patterns of this remodeling are attributed to mechanical and biological factors, and those changes in bone mineral density have been determined in long-term densitometry studies. This technique has proved to be a useful tool able to quantify small changes in bone density in different femoral areas, and it is considered to be ideal for long-term studies. On the other hand, the finite element (FE) simulation allows the study of the biomechanical changes produced in the femur after the implantation of a femoral stem. The aim of this study was to contrast the findings obtained from a 5 year follow-up densitometry study that used a newly designed femoral stem (73 patients were included in this study), with the results obtained using a finite element simulation that reproduces the pattern of load transfer that this stem causes on the femur. In this study we have obtained a good comparison between the results of stress of FE simulation and the bone mass values of the densitometry study establishing a ratio between the increases in stress (%) versus the increases in bone density (%). Hence, the changes in bone density in the long term, compared with the healthy femur, are due to different load transfers after stem implantation. It has been checked that in the Gruen zone 7 at 5 years, the most important reduction in stress (7.85%) is produced, which coincides with the highest loss of bone mass (23.89%). Furthermore, the simulation model can be used with different stems with several load conditions and at different time periods to carry out the study of biomechanical behavior in the interaction between the stem and the femur, explaining the evolution of bone density in accordance to Wolff’s law, which validates the simulation model.


2010 ◽  
Vol 28 (9) ◽  
pp. 1240-1244 ◽  
Author(s):  
Markus Oszwald ◽  
Ralf Westphal ◽  
Jan Bredow ◽  
Afshin Calafi ◽  
Tobias Hufner ◽  
...  

1996 ◽  
Vol 11 (2) ◽  
pp. 184-193 ◽  
Author(s):  
B. Jenny Kiratli ◽  
Mary M. Checovich ◽  
Andrew A. McBeath ◽  
Michael A. Wilson ◽  
John P. Heiner

Sign in / Sign up

Export Citation Format

Share Document