Lewis number effects on lean premixed combustion characteristics of multi-component fuel blends

2022 ◽  
Vol 238 ◽  
pp. 111932
Author(s):  
S. Zitouni ◽  
D. Pugh ◽  
A. Crayford ◽  
P.J. Bowen ◽  
J. Runyon
Author(s):  
P. Gokulakrishnan ◽  
M. J. Ramotowski ◽  
G. Gaines ◽  
C. Fuller ◽  
R. Joklik ◽  
...  

Dry low Emissions (DLE) systems employing lean, premixed combustion have been successfully used with natural gas in combustion turbines to meet stringent emissions standards. However, the burning of liquid fuels in DLE systems is still a challenging task due to the complexities of fuel vaporization and air premixing. Lean, Premixed, Prevaporized (LPP) combustion has always provided the promise of obtaining low pollutant emissions while burning liquid fuels such as kerosene and fuel oil. Because of the short ignition delay times of these fuels at elevated temperatures, the autoignition of vaporized higher hydrocarbons typical of most practical liquid fuels has proven difficult to overcome when burning in lean, premixed mode. To avoid this autoignition problem, developers of LPP combustion systems have focused mainly on designing premixers and combustors that permit rapid mixing and combustion of fuels before spontaneous ignition of the fuel can occur. However, none of the reported works in the literature has looked at altering fuel combustion characteristics in order to delay the onset of ignition in lean, premixed combustion systems. The work presented in this paper describes the development of a patented low-NOx LPP system for combustion of liquid fuels which modifies the fuel rather than the combustion hardware in order to achieve LPP combustion. In the initial phase of the development, laboratory-scale experiments were performed to study the combustion characteristics, such as ignition delay time and NOx formation, of the liquids fuels that were vaporized into gaseous form in the presence of nitrogen diluent. In phase two, an LPP combustion system was commissioned to perform pilot-scale tests on commercial turbine combustor hardware. These pilot-scale tests were conducted at typical compressor discharge temperatures and at both atmospheric and high pressures. In this study, vaporization of the liquid fuel in an inert environment has been shown to be a viable method for delaying autoignition and for generating a gaseous fuel stream with characteristics similar to natural gas. Tests conducted in both atmospheric and high pressure combustor rigs utilizing swirl-stabilized burners designed for natural gas demonstrated operation similar to that obtained when burning natural gas. Emissions levels were similar for both the LPP fuels (fuel oil #1 and #2) and natural gas, with any differences ascribed to the fuel-bound nitrogen present in the liquid fuels. Extended lean operation was observed for the liquid fuels as a result of the wider lean flammability range for these fuels compared with natural gas. Premature ignition of the LPP fuel was controlled by the level of inert gas in the vaporization process.


Author(s):  
Jae Hwan Jang ◽  
Ju Hyeong Cho ◽  
Han Seok Kim ◽  
Sang Min Lee ◽  
Min Kuk Kim ◽  
...  

Author(s):  
P. Gokulakrishnan ◽  
M. J. Ramotowski ◽  
G. Gaines ◽  
C. Fuller ◽  
R. Joklik ◽  
...  

Dry low emission (DLE) systems employing lean, premixed combustion have been successfully used with natural gas in combustion turbines to meet stringent emission standards. However, the burning of liquid fuels in DLE systems is still a challenging task due to the complexities of fuel vaporization and air premixing. Lean, premixed, and prevaporized (LPP) combustion has always provided the promise of obtaining low pollutant emissions while burning liquid fuels, such as kerosene and fuel oil. Because of the short ignition delay times of these fuels at elevated temperatures, the autoignition of vaporized higher hydrocarbons typical of most practical liquid fuels has been proven difficult to overcome when burning in a lean, premixed mode. To avoid this autoignition problem, developers of LPP combustion systems have focused mainly on designing premixers and combustors that permit rapid mixing and combustion of fuels before spontaneous ignition of the fuel can occur. However, none of the reported works in the literature has looked at altering fuel combustion characteristics in order to delay the onset of ignition in lean, premixed combustion systems. The work presented in this paper describes the development of a patented low NOx LPP system for combustion of liquid fuels, which modifies the fuel rather than the combustion hardware in order to achieve LPP combustion. In the initial phase of the development, laboratory-scale experiments were performed to study the combustion characteristics, such as ignition delay time and NOx formation, of the liquid fuels that were vaporized into gaseous form in the presence of nitrogen diluent. In the second phase, a LPP combustion system was commissioned to perform pilot-scale tests on commercial turbine combustor hardware. These pilot-scale tests were conducted at typical compressor discharge temperatures and at both atmospheric and high pressures. In this study, vaporization of the liquid fuel in an inert environment has been shown to be a viable method for delaying autoignition and for generating a gaseous fuel stream with characteristics similar to natural gas. Tests conducted in both atmospheric and high pressure combustor rigs utilizing swirl-stabilized burners designed for natural gas demonstrated an operation similar to that obtained when burning natural gas. Emission levels were similar for both the LPP fuels (fuel oils 1 and 2) and natural gas, with any differences ascribed to the fuel-bound nitrogen present in the liquid fuels. An extended lean operation was observed for the liquid fuels as a result of the wider lean flammability range for these fuels compared to natural gas.


Author(s):  
David G. Nicol ◽  
Philip C. Malte ◽  
Robert C. Steele

Simplified models for predicting the rate of production of NOx in lean-premixed combustion are presented. These models are based on chemical reactor modeling, and are influenced strongly by the nitrous oxide mechanism, which is an important source of NOx in lean-premixed combustion. They include 1) the minimum set of reactions required for predicting the NOx production, and 2) empirical correlations of the NOx production rate as a function of the CO concentration. The later have been developed for use in an NOx post-processor for CFD codes. Also presented are recent laboratory data, which support the chemical rates used in this study.


Author(s):  
Rajiv Mongia ◽  
Robert Dibble ◽  
Jeff Lovett

Lean premixed combustion has emerged as a method of achieving low pollutant emissions from gas turbines. A common problem of lean premixed combustion is combustion instability. As conditions inside lean premixed combustors approach the lean flammability limit, large pressure variations are encountered. As a consequence, certain desirable gas turbine operating regimes are not approachable. In minimizing these regimes, combustor designers must rely upon trial and error because combustion instabilities are not well understood (and thus difficult to model). When they occur, pressure oscillations in the combustor can induce fluctuations in fuel mole fraction that can augment the pressure oscillations (undesirable) or dampen the pressure oscillations (desirable). In this paper, we demonstrate a method for measuring the fuel mole fraction oscillations which occur in the premixing section during combustion instabilities produced in the combustor that is downstream of the premixer. The fuel mole fraction in the premixer is measured with kHz resolution by the absorption of light from a 3.39 μm He-Ne laser. A sudden expansion combustor is constructed to demonstrate this fuel mole fraction measurement technique. Under several operating conditions, we measure significant fuel mole fraction fluctuations that are caused by pressure oscillations in the combustion chamber. Since the fuel mole fraction is sampled continuously, a power spectrum is easily generated. The fuel mole fraction power spectrum clearly indicates fuel mole fraction fluctuation frequencies are the same as the pressure fluctuation frequencies under some operating conditions.


Author(s):  
Keita Yunoki ◽  
Tomoya Murota ◽  
Keisuke Miura ◽  
Teruyuki Okazaki

We have developed a burner for the gas turbine combustor, which was high efficiency and low environmental load. This burner is named the “coaxial jet cluster burner” and, as the name indicates, it has multiple fuel nozzles and holes in a coaxial arrangement. To form lean premixed combustion, this burner mixes fuel and air in the multiple holes rapidly. The burner can change the combustion form between premixed and non-premixed combustion by controlling the mixing. However, the combustion field coexisting with premixed and non-premixed combustion is complicated. The phenomena that occur in the combustion field should be understood in detail. Therefore, we have developed the hybrid turbulent combustion (HTC) model to calculate the form in which non-premixed flame coexists with premixed flame. Turbulent flow has been simulated using a large eddy simulation (LES) with a dynamic sub grid scale (SGS) model coupled with the HTC model. These models were programmed to a simulation tool based on the OpenFOAM library. However, there were unclear points about their applicability to an actual machine evaluation and the predictive precision of CO concentration which affects burner performance. In this study, we validate the HTC model by comparing its results with measured gas temperature and gas concentration distributions obtained with a coaxial jet cluster burner test rig under atmospheric pressure. In addition, we analyze the CO generation mechanism for the lean premixed combustion in the burner.


2021 ◽  
Author(s):  
Chao Xu ◽  
Muhsin Ameen ◽  
Pinaki Pal ◽  
Sibendu Som

Abstract Partial fuel stratification (PFS) is a promising fuel injection strategy to stabilize lean premixed combustion in spark-ignition (SI) engines. PFS creates a locally stratified mixture by injecting a fraction of the fuel, just before spark timing, into the engine cylinder containing homogeneous lean fuel/air mixture. This locally stratified mixture, when ignited, results in complex flame structure and propagation modes similar to partially premixed flames, and allows for faster and more stable flame propagation than a homogeneous lean mixture. This study focuses on understanding the detailed flame structures associated with PFS-assisted lean premixed combustion. First, a two-dimensional direct numerical simulation (DNS) is performed using detailed fuel chemistry, experimental pressure trace, and realistic initial conditions mapped from a prior engine large-eddy simulation (LES), replicating practical lean SI operating conditions. DNS results suggest that conventional triple flame structures are prevalent during the initial stage of flame kernel growth. Both premixed and non-premixed combustion modes are present with the premixed mode contributing dominantly to the total heat release. Detailed analysis reveals the effects of flame stretch and fuel pyrolysis on the flame displacement speed. Based on the DNS findings, the accuracy of a hybrid G-equation/well-stirred reactor (WSR) combustion model is assessed for PFS-assisted lean operation in the LES context. The G-equation model qualitatively captures the premixed branches of the triple flame, while the WSR model predicts the non-premixed branch of the triple flame. Finally, potential needs for improvements to the hybrid G-equation/WSR modeling approach are discussed.


Sign in / Sign up

Export Citation Format

Share Document