Simplified design-oriented axial stress-strain model for FRP-confined normal- and high-strength concrete

2018 ◽  
Vol 175 ◽  
pp. 501-516 ◽  
Author(s):  
Ali Fallah Pour ◽  
Togay Ozbakkaloglu ◽  
Thomas Vincent
2014 ◽  
Vol 919-921 ◽  
pp. 29-34 ◽  
Author(s):  
Jian Chin Lim ◽  
Togay Ozbakkloglu

It is well established that lateral confinement of concrete enhances its axial strength and deformability. It is often assumed that, at a same level of confining pressure, the axial compressive stress and strain of fiber reinforced polymer (FRP)-confined concrete at a given lateral strain are the same as those in concrete actively confined concrete. To assess the validity of this assumption, an experimental program relating both types of confinement systems was conducted. 25 FRP-confined and actively confined high-strength concrete (HSC) specimens cast from a same batch of concrete were tested under axial compression. The axial stress-strain and lateral strain-axial strain curves obtained from the two different confinement systems were assessed. The results indicate that, at a given axial strain, lateral strains of actively confined and FRP-confined concretes correspond, when they are subjected to the same lateral confining pressure. However, it is observed that, at these points of intersections on axial strain-lateral strain curves, FRP-confined concrete exhibits a lower axial stress than the actively confined concrete, indicating that the aforementioned assumption is not accurate. The test results indicate that the difference in the axial stresses of FRP-confined and actively confined HSC becomes more significant with an increase in the level of confining pressure.


2013 ◽  
Vol 671-674 ◽  
pp. 1860-1864 ◽  
Author(s):  
Thomas Vincent ◽  
Togay Ozbakkloglu

It is well established that external confinement of concrete with fiber reinforced polymer (FRP) sheets results in significant improvements on the axial compressive behavior of concrete. This understanding has led to a large number of experimental studies being conducted over the last two decades. However, the majority of these studies have focused on normal strength concretes (NSC) with compressive strengths lower than 55 MPa, and studies on higher strength concretes have been very limited. This paper presents the results of an experimental study on the compressive behavior of FRP confined high- and ultra high-strength concrete (HSC and UHSC) with average compressive strengths of 65 and 100 MPa. A total of 29 specimens were tested under axial compression to investigate the influence of key parameters such as concrete strength and method of confinement. All specimens were cylindrical, confined with carbon FRP and were 305 mm in height and 152 mm in diameter. Results obtained from the laboratory testing were graphically presented in the form of axial stress-strain relationships and key experimental outcomes are discussed. The results of this experimental study indicate that above a certain confinement threshold, FRP-confined HSC and UHSC exhibit highly ductile behavior. The results also indicate that FRP-wrapped specimens perform similar to concrete-filled FRP tube (CFFT) specimens at ultimate condition, however notable differences are evident at the transition region when comparing stress-strain curves.


Sign in / Sign up

Export Citation Format

Share Document