Influence of surface roughness on a spray cooling system with R134a. Part I: Heat transfer measurements

2013 ◽  
Vol 46 ◽  
pp. 183-190 ◽  
Author(s):  
Eduardo Martínez-Galván ◽  
Raúl Antón ◽  
Juan Carlos Ramos ◽  
Rahmatollah Khodabandeh
Author(s):  
Azzam S. Salman ◽  
Jamil A. Khan

Experiments were conducted in a closed loop spray cooling system working with deionized water as a working fluid. This study was performed to investigate the effect of the spraying parameters, such as Sauter mean diameter (SMD), the droplet velocity, and the residual velocity on the spray cooling heat transfer in the non-boiling region. Thermal effects on plain and modified surfaces with circular grooves were examined under different operating conditions. The inlet pressure of the working fluid was varied from 78.6 kPa to 183.515kPa, and the inlet temperature was kept between 21–22 °C. The distance between the nozzle and the target surface 10 mm. The results showed that increasing the coolant inlet pressure increases the droplet velocity and the number of droplets produced while decreasing the droplet size. As a consequence of these changes, increasing inlet pressure improved the heat transfer characteristics of both surfaces.


Energies ◽  
2019 ◽  
Vol 12 (20) ◽  
pp. 3963 ◽  
Author(s):  
Jia-Xin Li ◽  
Yun-Ze Li ◽  
Ben-Yuan Cai ◽  
En-Hui Li

This paper presents an air-oriented spray cooling system (SCS) integrated with a two-phase ejector for the thermal management system. Considering its aeronautical application, the spray nozzle in the SCS is an air-blast one. Heat transfer performance (HTP) of air-water spray cooling was studied experimentally on the basis of the ground-based test. Factors including pressure difference between water-inlet-pressure (WIP) and spray cavity one (PDWIC) and the spray volumetric flow rate (SVFR) were investigated and discussed. Under a constant operating condition, the cooling capacity can be promoted by the growth factors of the PDWIC and SVFR with the values from 51.90 kPa to 235.35 kPa and 3.91 L ⋅ h − 1 to 14.53 L ⋅ h − 1 , respectively. Under the same heating power, HTP is proportional to the two dimensionless parameters Reynolds number and Weber number due to the growth of droplet-impacting velocity and droplet size as the increasing of PDWIC or SVFR. Additionally, compared with the factor of the droplet size, the HTP is more sensitive to the variation in the droplet-impacting velocity. Based on the experimental data, an empirical experimental correlation for the prediction of the dimensionless parameter Nusselt number in the non-boiling region with the relative error of only ± 10 % was obtained based on the least square method.


2008 ◽  
Vol 130 (10) ◽  
Author(s):  
Ruey-Hung Chen ◽  
David S. Tan ◽  
Kuo-Chi Lin ◽  
Louis C. Chow ◽  
Alison R. Griffin ◽  
...  

Droplet and bubble dynamics and nucleate heat transfer in saturated FC-72 spray cooling were studied using a simulation model. The spray cooling system simulated consists of three droplet fluxes impinging on a smooth heater, where secondary nuclei outnumber the surface nuclei. Using the experimentally observed bubble growth rate on a smooth diamond heater, submodels were assumed based on physical reasoning for the number of secondary nuclei entrained by the impinging droplets, bubble puncturing by the impinging droplets, bubble merging, and the spatial distribution of secondary nuclei. The predicted nucleate heat transfer was in agreement with experimental findings. Dynamic aspects of the droplets and bubbles, which had been difficult to observe experimentally, and their ability in enhancing nucleate heat transfer were then discussed based on the results of the simulation. These aspects include bubble merging, bubble puncturing by impinging droplets, secondary nucleation, bubble size distribution, and bubble diameter at puncture. Simply increasing the number of secondary nuclei is not as effective in enhancing nucleate heat transfer as when it is also combined with increased bubble puncturing frequency by the impinging droplets. For heat transfer enhancement, it is desirable to have as many small bubbles and as high a bubble density as possible.


2011 ◽  
Vol 133 (1) ◽  
Author(s):  
Eduardo Martínez-Galván ◽  
Juan Carlos Ramos ◽  
Raúl Antón ◽  
Rahmatollah Khodabandeh

Experimental measurements in a spray cooling test rig have been carried out for several heat fluxes in the heater and different spray volumetric fluxes with the dielectric refrigerant R134a. Results of the heat transfer and the sprayed refrigerant film thickness measurements are presented. The film thickness measurements have been made with a high speed camera equipped with a long distance microscope. It has been found that there is a relation between the variation in the average Nusselt number and the film thickness along the spray cooling boiling curve. The heat transfer regimes along that curve are related not only with a variation in the average Nusselt number but also with changes in the film thickness. The qualitative analysis of those variations has served to understand better the heat transfer mechanisms occurring during the spray cooling.


Author(s):  
Azzam S. Salman ◽  
Jamil A. Khan

An experimental study was conducted in a closed loop spray cooling system working with deionized water as a cooling medium, to investigate the effects of surface modification on the spray cooling heat transfer enhancement in the single-phase region. Plain copper surface with diameter 1.5 cm and an enhanced surface with circular grooves were tested under different operating conditions. The volumetric flow rate of the coolant ranged from 115 mL/min to 177 mL/min., and the water inlet temperature was kept between 21–23 °C. Also, the distances between the nozzle and the target surface were varied at 8, 10, and 12 mm respectively. The results show that the distance between the nozzle and the target surface did not have a significant effect on the heat transfer performance for the low flow rates, while it has a slight effect on high flow rates for both surfaces. Also, increasing the liquid volumetric flow rate increases the amount of heat removed, and the heat transfer coefficient for both surfaces. Moreover, the maximum enhancement ratios achieved were 23.4% and 31% with volumetric flow rates of 153 mL/min, and 177 mL/min respectively.