Novel optical devices based on the tunable refractive index of magnetic fluid and their characteristics

2011 ◽  
Vol 323 (23) ◽  
pp. 2987-2996 ◽  
Author(s):  
Yong Zhao ◽  
Yuyan Zhang ◽  
Riqing Lv ◽  
Qi Wang
2003 ◽  
Vol 94 (6) ◽  
pp. 3849-3852 ◽  
Author(s):  
Chin-Yih Hong ◽  
S. Y. Yang ◽  
H. E. Horng ◽  
H. C. Yang

Nanomaterials ◽  
2020 ◽  
Vol 10 (2) ◽  
pp. 290 ◽  
Author(s):  
Hung-Chi Yen ◽  
Tsung-Rong Kuo ◽  
Chun-Ta Wang ◽  
Jia-De Lin ◽  
Chia-Chun Chen ◽  
...  

A system comprising a gold nanoisland film (Au NIF) covered with a liquid crystal (LC) material is introduced. By applying a voltage across the LC bulk, we demonstrate that changes in the refractive-index and orientation significantly modified the hybrid plasmonic–photonic resonances of the Au NIF. The hybrid structure enabled active control of the spectrum of the resonance wavelength of the metallic nanoisland by means of an externally applied electric field. Our modeling supports the observed results in LC/Au NIF. In a combination of the nanostructured surface with birefringent LCs, nonpolarized wavelength tunability of ~15 nm and absorbance tunability of ~0.024 were achieved in the visible wavelength, opening the door to optical devices and nanoscale sensors.


Micromachines ◽  
2019 ◽  
Vol 10 (10) ◽  
pp. 628
Author(s):  
Lin ◽  
Yi ◽  
Cao ◽  
Lv ◽  
Yang ◽  
...  

This paper presents a novel electrode thermal writing waveguide based on a heating-induced refractive index change mechanism. The mode condition and the electrode thermal writing parameters were optimized, and the output patterns of the optical field were obtained in a series of simulations. Moreover, the effect of various adjustments on the sensing range of the nanoimprint M-Z temperature sensor was analyzed theoretically. A refractive index asymmetry Mach–Zehnder (M-Z) waveguide sensor with a tunable refractive index for a waveguide core layer was simulated with a length difference of 946.1 µm. The optimal width and height of the invert ridge waveguide were 2 μm and 2.8 μm, respectively, while the slab thickness was 1.2 μm. The sensing accuracy was calculated to range from 2.0896 × 104 to 5.1252 × 104 in the 1.51–1.54 region. The sensing fade issue can be resolved by changing the waveguide core refractive index to 0.001 via an electrode thermal writing method. Thermal writing a single M-Z waveguide arm changes its refractive index by 0.03. The sensor’s accuracy can be improved 1.5 times by the proposed method. The sensor described in this paper shows great prospects in organism temperature detection, molecular analysis, and biotechnology applications.


2020 ◽  
Vol 14 ◽  
Author(s):  
Bo M. B. Bekkouche ◽  
Helena K. M. Fritz ◽  
Elisa Rigosi ◽  
David C. O'Carroll

Improvement of imaging quality has the potential to visualize previously unseen building blocks of the brain and is therefore one of the great challenges in neuroscience. Rapid development of new tissue clearing techniques in recent years have attempted to solve imaging compromises in thick brain samples, particularly for high resolution optical microscopy, where the clearing medium needs to match the high refractive index of the objective immersion medium. These problems are exacerbated in insect tissue, where numerous (initially air-filled) tracheal tubes branching throughout the brain increase the scattering of light. To date, surprisingly few studies have systematically quantified the benefits of such clearing methods using objective transparency and tissue shrinkage measurements. In this study we compare a traditional and widely used insect clearing medium, methyl salicylate combined with permanent mounting in Permount (“MS/P”) with several more recently applied clearing media that offer tunable refractive index (n): 2,2′-thiodiethanol (TDE), “SeeDB2” (in variants SeeDB2S and SeeDB2G matched to oil and glycerol immersion, n = 1.52 and 1.47, respectively) and Rapiclear (also with n = 1.52 and 1.47). We measured transparency and tissue shrinkage by comparing freshly dissected brains with cleared brains from dipteran flies, with or without addition of vacuum or ethanol pre-treatments (dehydration and rehydration) to evacuate air from the tracheal system. The results show that ethanol pre-treatment is very effective for improving transparency, regardless of the subsequent clearing medium, while vacuum treatment offers little measurable benefit. Ethanol pre-treated SeeDB2G and Rapiclear brains show much less shrinkage than using the traditional MS/P method. Furthermore, at lower refractive index, closer to that of glycerol immersion, these recently developed media offer outstanding transparency compared to TDE and MS/P. Rapiclear protocols were less laborious compared to SeeDB2, but both offer sufficient transparency and refractive index tunability to permit super-resolution imaging of local volumes in whole mount brains from large insects, and even light-sheet microscopy. Although long-term permanency of Rapiclear stored samples remains to be established, our samples still showed good preservation of fluorescence after storage for more than a year at room temperature.


2015 ◽  
Vol 48 ◽  
pp. 59-65 ◽  
Author(s):  
Ji Ma ◽  
Xiang-Yao Wu ◽  
Hai-Bo Li ◽  
Hong Li ◽  
Xiao-Jing Liu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document