Aortic Remodeling After False Lumen Occlusion Using an Atrial Septal Occluder in Chronic DeBakey IIIb Aortic Dissection

Author(s):  
Heng Lu ◽  
Zhiqin Lin ◽  
Yi Chen ◽  
Feng Lin ◽  
Xiaofu Dai ◽  
...  
2021 ◽  
pp. 152660282199672
Author(s):  
Ahmed Eleshra ◽  
Fiona Rohlffs ◽  
Konstantinos Spanos ◽  
Giuseppe Panuccio ◽  
Franziska Heidemann ◽  
...  

Purpose: To report a single-center experience with the use of a custom-made Candy-Plug (CP) for distal false-lumen (FL) occlusion in subacute and chronic aortic dissection (AD). Materials and Methods: A retrospective single-center analysis was conducted on consecutive patients with subacute and chronic AD who were treated with a custom-made CP for distal FL occlusion using 3 design generations (CP I to CP III) from October 2013 to September 2019. Results: A custom-made CP was used in 57 patients. Of these, 34 patients (29 males, mean age 62±10 years) were treated with a CP I vs 23 patients (16 males, mean age 59±17 years) with CP II/III. Technical success was achieved in 57 (100%) patients. Clinical success was achieved in 54 (95%) patients; 33 (97%) in CP I group vs 21 (91%) patients in CP II/III group, p=0.116. The mean hospital stay was 10±8 days (9±5 days in CP I group vs 13±9 days in CP II/III, p=0.102). The 30-day computed tomography angiography (CTA) confirmed successful CP placement at the intended level in all patients within both groups. Early complete FL occlusion was achieved in 50 (88%) patients; 30 (88%) patients in CP I group vs 20 (87%) in CP II/III group, p=0.894. Follow up CTA was available in 44 (77%) patients. Of these; 30/34 (88%) patients in CP I group with mean follow-up 29±17 months) vs. 14/23 (61%) patients with mean follow-up 14±5 months in CP II/III group. Thoracic aortic remodeling was achieved in 34/44 (77%) patients; 25/30 (83%) patients in CP I group vs 9/14 (64%) patients in CP II/III group, p=0.197. The aneurysm size remained stable in 9/44 (20%) patients; 5/30 (17%) patients in CP I group vs 4/14 (29%) patients in CP II/III group, p=0.741. The thoracic aneurysm increased size was seen in 1/44 (2%) patient. This patient was in CPII/III group. Conclusion: CP technique using custom-made devices is technically feasible with a low mortality and morbidity, and a high rate of aortic remodeling. Both, the original design (CP I) and newer designs with a self-closing central sleeve (CP II and CP III) showed similar excellent outcomes.


2019 ◽  
Vol 26 (6) ◽  
pp. 782-786 ◽  
Author(s):  
Ahmed Eleshra ◽  
Tilo Kölbel ◽  
Nikolaos Tsilimparis ◽  
Giuseppe Panuccio ◽  
Martin Scheerbaum ◽  
...  

Purpose: To present the early results of false lumen (FL) occlusion in chronic aortic dissection using the Candy-Plug generation II (CP II), which has a self-closing fabric channel that obviates the need for separate occlusion of its center. Materials and Methods: Fourteen consecutive patients (mean age 60±11 years; 10 men) with persistent FL backflow and aneurysm formation at the thoracic segment in chronic aortic dissection underwent thoracic endovascular aortic repair (TEVAR) with FL occlusion using the refined CP II. Primary endpoints were technical success (successful deployment) and clinical success (no FL backflow at the CP II level). Secondary endpoints included 30-day mortality and morbidity and aortic remodeling during follow-up. Results: Technical success was 100%. One patient required additional intraprocedural FL embolization at the CP II level due to persistent FL backflow on final angiography (clinical success 93%), though there was no flow through the CP II center. There were no intraprocedural complications. Immediate complete FL occlusion was achieved in 12 patients; the other 2 required reintervention. One had contrast enhancement in the distal FL proximal to the CP II and was treated with coil embolization. The other patient had persistent type I endoleak at the level of the left subclavian artery (LSA) and underwent left carotid–LSA bypass and proximal stent-graft extension. One patient died due to retrograde type A aortic dissection that was not related to CP II placement. Over a mean 8-month follow-up (range 3–12), 9 patients had computed tomography angiography; 8 patients had evidence of aortic remodeling, while 1 aneurysm sac was stable. Conclusion: The CP II reduces the number of procedural steps and offers good seal, with minimal morbidity and mortality and a high rate of aortic remodeling.


2019 ◽  
Vol 70 (3) ◽  
pp. 710-717 ◽  
Author(s):  
Quentin Pellenc ◽  
Arnaud Roussel ◽  
Romain De Blic ◽  
Antoine Girault ◽  
Pierre Cerceau ◽  
...  

Author(s):  
Chaojie Wang ◽  
Wenqian Zhang ◽  
Jihai Peng ◽  
Jie He ◽  
Wenliu Xu ◽  
...  

OBJECTIVES: The frozen elephant trunk (FET) technique has become an important tool in the treatment of acute type A aortic dissection. The aim of this study was to evaluate the effect of long FET on spinal cord injury (SCI) and distal aortic remodeling after acute type A aortic dissection based on clinical and radiological outcomes. METHODS: From January 2018 to November 2019, 158 patients [mean age 51.8 years (range 32 - 78 years), 88.6% male] with acute type A aortic dissection were treated by FET with 100 mm (n=113) or 150 mm (n=45) open hybrid stent graft prosthesis. Patients were divided into two groups according to the length of FET. The clinical and radiological outcomes of the patients were reviewed retrospectively. RESULTS: Postoperative outcomes did not differ significantly: in-hospital mortality (9.7% vs 6.7%, P=0.758) and SCI (5.3% vs 2.2%, P=0.674). Aortic remodeling, which was evaluated by aortic diameter, true lumen diameter, false lumen diameter and the rate of false lumen complete thrombosis, was more positive in long FET group in the descending thoracic aorta during the follow-up period. At the abdominal level, there was no statistically significant difference between the two groups. CONCLUSIONS: The long version of FET does not increase the risk of SCI in patients with acute type A aortic dissection. The application of long FET can achieve better results in terms of remodeling of the thoracic aorta in the short- and medium-term follow-up.


2021 ◽  
Vol 108 (Supplement_4) ◽  
Author(s):  
S Jungi ◽  
S Mylonas ◽  
M Ante ◽  
W Ahmad ◽  
K Meisenbacher ◽  
...  

Abstract Objective In the past years, a paradigm shift from best medical therapy to early thoracic endovascular aortic repair (TEVAR) has been observed in the treatment of uncomplicated type B aortic dissection (uTBAD). We aimed to analyze outcomes after TEVAR in the acute and subacute phase of uTBAD, focusing on aortic remodeling. Methods Retrospective analysis of consecutive patients who underwent TEVAR for acute or subacute uTBAD in two tertiary referral centers from 2008 – 2017. Two assessors per center reviewed computed tomography scans of each patient at presentation, at one year and at the last follow-up using post-processing software. Results Forty-nine patients were treated with TEVAR for uTBAD. The indication for TEVAR was the presence of multiple morphologic predictors of adverse aortic outcome. The most common predictors were a false lumen diameter of > = 22mm in 76% of patients, a primary entry tear of > = 10mm in 69% and a total aortic diameter of > = 40mm in 67%. There were no in-hospital deaths and no deaths at 1 year. The median follow-up was 40.6 months. Three-year cumulative survival was 94 % (46/49). Fourteen secondary interventions were performed in 10 patients (20 %) after a median of 4.2 months. TEVAR lead to remodeling of the descending thoracic aorta with a median reduction of the total aortic diameter of 4.5 mm within one year and stable diameters after three years. The median maximum false lumen diameter diminished from 26 mm to 15 mm in one year (at 3 years: 14.8 mm). Conclusion In this cohort of selected patients with uTBAD and multiple morphologic predictors of worse aortic outcome, elective acute or subacute TEVAR was associated with a low mortality and positive aortic remodeling in the mid-term follow-up.


2021 ◽  
Author(s):  
Chaojie Wang ◽  
Wenqian Zhang ◽  
Jihai Peng ◽  
Jie He ◽  
Guangtian Chen ◽  
...  

Abstract Background: The frozen elephant trunk (FET) technique has become an important tool in the treatment of acute type A aortic dissection. The aim of this study was to evaluate the effect of long FET on spinal cord injury (SCI) and distal aortic remodeling after acute type A aortic dissection based on clinical and radiological outcomes.METHODS: From January 2018 to November 2019, 158 patients [mean age 51.8 years (range 32 - 78 years), 88.6% male] with acute type A aortic dissection were treated by FET with 100 mm (n=113) or 150 mm (n=45) open hybrid stent graft prosthesis. Patients were divided into two groups according to the length of FET. The clinical and radiological outcomes of the patients were reviewed retrospectively. RESULTS: Postoperative outcomes did not differ significantly: in-hospital mortality (9.7% vs 6.7%, P=0.758) and SCI (5.3% vs 2.2%, P=0.674). Aortic remodeling, which was evaluated by aortic diameter, true lumen diameter, false lumen diameter and the rate of false lumen complete thrombosis, was more positive in long FET group in the descending thoracic aorta during the follow-up period. At the abdominal level, there was no statistically significant difference between the two groups. In the long FET group, the level of complete false lumen thrombosis was more extensive during the follow-up period. CONCLUSIONS: The long version of FET does not increase the risk of SCI in patients with acute type A aortic dissection. The application of long FET can achieve better results in terms of remodeling of the thoracic aorta in the short- and medium-term follow-up.


Sign in / Sign up

Export Citation Format

Share Document