Determining trace metal elements in the tooth enamel from Hui and Han Ethnic groups in China using microwave digestion and inductively coupled plasma mass spectrometry (ICP-MS)

2016 ◽  
Vol 127 ◽  
pp. 142-144 ◽  
Author(s):  
Maoyong He ◽  
Hai Lu ◽  
Chongguang Luo ◽  
Tongxiang Ren
2005 ◽  
Vol 88 (6) ◽  
pp. 1811-1821 ◽  
Author(s):  
Laurent Noël ◽  
Vincent Dufailly ◽  
Nadège Lemahieu ◽  
Christelle Vastel ◽  
Thierry Guérin

Abstract A method validation of the total analysis of cadmium (Cd), lead (Pb), arsenic (As), and mercury (Hg) in foodstuffs by inductively coupled plasma/mass spectrometry (ICP/MS) after closed vessel microwave digestion is presented. Due to the lack of reference method for ICP/MS techniques in food and, based on the project of the European Committee of Normalization (CEN/TC 275/WG 10), the Agence Française de Normalisation (AFNOR) guidelines NF V03–110 were used for the evaluation of this method based on 2 steps, sample preparation and multielement detection. Several criteria considered as compulsory (linearity, specificity, precision under repeatability conditions, and trueness) have been estimated and discussed, in addition to intermediate precision reproducibility, the limit of detection, and the limit of quantification. Furthermore, a comparison with in-house methods using electrothermal atomic absorption was performed using an external proficiency testing scheme and food samples. The results indicated that this method could be used in the laboratory for the routine determination of these 4 cumulative toxic metals in foodstuffs with acceptable analytical performance.


2003 ◽  
Vol 86 (6) ◽  
pp. 1225-1231 ◽  
Author(s):  
Laurent Noël ◽  
Thierry Guérin ◽  
Jean-Marc Frémy ◽  
Hélène Huet ◽  
Martine Kolf-Clauw

Abstract A rapid procedure, based on closed vessels microwave digestion and inductively coupled plasma-mass spectrometry (ICP-MS), was evaluated to ascertain the effect of chronic exposure to cadmium on intracellular accumulation of minor and essential trace elements in cultured epithelial cells (Caco-2 TC7). For all measurements, the method of external calibration was used and 3 elements (Be, Sc, In) were selected as internal standards. Optimization procedures are discussed and results are presented for the total determination of 9 key analytes (Na, Mg, Ca, Cr, Mn, Cu, Zn, Mo, and Cd) in certified reference materials (CRMs) and 20 samples of Caco-2 TC7 cells long-term exposed to Cd. The performance characteristics of the analytical system were evaluated by calibration and linearity, limits of detection and quantitation, accuracy with spiking, trueness and repeatability with available CRMs. As a complement to the ICP-MS determinations, both available CRMs and cell samples were analyzed either by electro thermal-or flame atomic absorption spectrometry. The results were in good agreement with the ICP-MS results.


2014 ◽  
Vol 28 (7) ◽  
pp. 4517-4522 ◽  
Author(s):  
Shifeng Dai ◽  
Weijiao Song ◽  
Lei Zhao ◽  
Xiao Li ◽  
James C. Hower ◽  
...  

2013 ◽  
Vol 423-426 ◽  
pp. 767-770
Author(s):  
Ting Zhao ◽  
Ming Qiang Zhou ◽  
Wei Li Liu ◽  
Wei Huang ◽  
Jun Zhi He ◽  
...  

Based on microwave digestion and dry digestion, the concentrations of Si, S, Ca, Cr, Fe, Ni, Cu, Al, Mo, Sb, Ti, V, Y and Zn in carbon fiber were determined using inductively coupled plasma mass spectrometry (ICP-MS). Compare with the concentrations in the solution got by microwave digestion, the concentrations in the solution got by dry digestion are higher. And microwave digestion is more suitable for treatment of carbon fiber containing volatile elements than dry digestion.


Sign in / Sign up

Export Citation Format

Share Document