DELIVERY QA OF HELICAL TOMOTHERAPY PLANS IN A THORACIC IMRT PHANTOM USING ION CHAMBER, MOSFET AND EDR2 FILM

2009 ◽  
Vol 92 ◽  
pp. S211-S212
Author(s):  
R. Phurailatpam ◽  
R.R. Upreti
2008 ◽  
Vol 7 (6) ◽  
pp. 425-432 ◽  
Author(s):  
Maximilien Schirm ◽  
Slav Yartsev ◽  
Glenn Bauman ◽  
Jerry Battista ◽  
Jake Van Dyk

This study aims to evaluate a new Planned Adaptive® software (TomoTherapy Inc., Madison, WI) of the helical tomotherapy system by retrospective verification and adaptive re-planning of radiation treatment. Four patients with different disease sites (brain, nasal cavity, lungs, prostate) were planned in duplicate using the diagnostic planning kVCT data set and MVCT studies of the first treatment fraction with the same optimization parameters for both plan types. The dosimetric characteristics of minimum, maximum, and mean dose to the targets as well as to organs at risk were compared. Both sets of plans were used for calculation of dose distributions in a water-equivalent phantom. Corresponding measurements of these plans in phantom were carried out with the use of radiographic film and ion chamber. In the case of the lung and prostate cancer patients, changes in dosimetric parameters compared to data generated with the kVCT study alone were less than 2%. Certain changes for the nasal cavity and brain cancer patients were greater than 2%, but they were explained in part by anatomy changes that occurred during the time between kVCT and MVCT studies. The Planned Adaptive software allows for adaptive radiotherapy planning using the MVCT studies obtained by the helical tomotherapy imaging system.


2015 ◽  
Vol 11 (3) ◽  
pp. 3146-3155
Author(s):  
Luhua Wang

Purpose: To evaluate the usefulness of helical tomotherapy (HT) in the treatment of advanced esophageal cancer (EC) and compare target homogeneity, conformity and normal tissue doses between HT and fixed-field intensity-modulated radiotherapy (ff-IMRT).Methods: In all, 23 patients with cT3-4N0-1M0-1a thoracic EC (upper esophagus, 9 patients; middle esophagus, 6; distal esophagus, 6 and esophagogastric junction, 2) who were treated with ff-IMRT (60 Gy in 30 fractions) were re-planned for HT and ff-IMRT with the same clinical require­ments. Comparisons were performed using the Wilcoxon matched-pair signed-rank test.Results: Compared with ff-IMRT, HT significantly reduced the homogeneity index for thoracic, upper, middle and distal ECs by 38%, 31%, 36% and 33%, respectively (P < 0.05). The conformity index was increased by HT for thoracic, upper and middle ECs by 9%, 9% and 18%, respectively (P < 0.05). Target coverage was improved by 1% with HT (P < 0.05). The mean lung dose was significantly reduced by HT for thoracic and upper ECs (P < 0.05). The V20 (volume receiving at least 20 Gy) and higher dose volumes of the lungs were decreased by HT in all cases, but the differences were significant for thoracic, upper and distal ECs (P < 0.05), with reductions of 2.1%, 3.1% and 2.2%, respectively. HT resulted in a larger lung V5 for thoracic, upper, middle and distal ECs, with increases of 3.5%, 1.5%, 7.2% and 3.2%, respectively. Heart sparing was significantly better with HT than with ff-IMRT in terms of the V30 and V40 for thoracic, upper, middle and distal ECs (P < 0.05).Conclusions: Compared to ff-IMRT, HT provides superior target coverage, conformity and homogeneity, with reduced the volume of high doses to the lungs and heart for advanced EC. HT may be a treatment option for advanced EC, especially upper EC.


Solar Physics ◽  
1972 ◽  
Vol 22 (1) ◽  
pp. 235-239 ◽  
Author(s):  
Richard G. Teske ◽  
Philip E. Hodge ◽  
Simon P. Worden
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document