scholarly journals Validity and reliability of body composition analysers in children and adults

2008 ◽  
Vol 100 (4) ◽  
pp. 859-865 ◽  
Author(s):  
Nicole E. Jensky-Squires ◽  
Christina M. Dieli-Conwright ◽  
Amerigo Rossuello ◽  
David N. Erceg ◽  
Scott McCauley ◽  
...  

We tested the validity and reliability of the BioSpace InBody 320, Omron and Bod-eComm body composition devices in men and women (n 254; 21–80 years) and boys and girls (n 117; 10–17 years). We analysed percentage body fat (%BF) and compared the results with dual-energy X-ray absorptiometry (DEXA) in adults and compared the results of the InBody with underwater weighing (UW) in children. All body composition devices were correlated (r 0·54–0·97; P ≤ 0·010) to DEXA except the Bod-eComm in women aged 71–80 years (r 0·54; P = 0·106). In girls, the InBody %BF was correlated with UW (r 0·79; P ≤ 0·010); however, a more moderate correlation (r 0·69; P ≤ 0·010) existed in boys. Bland–Altman plots indicated that all body composition devices underestimated %BF in adults (1·0–4·8 %) and overestimated %BF in children (0·3–2·3 %). Lastly, independent t tests revealed that the mean %BF assessed by the Bod-eComm in women (aged 51–60 and 71–80 years) and in the Omron (age 18–35 years) were significantly different compared with DEXA (P ≤ 0·010). In men, the Omron (aged 18–35 years), and the InBody (aged 36–50 years) were significantly different compared with DEXA (P = 0·025; P = 0·040 respectively). In addition, independent t tests indicated that the InBody mean %BF in girls aged 10–17 years was significantly different from UW (P = 0·001). Pearson's correlation analyses demonstrated that the Bod-eComm (men and women) and Omron (women) had significant mean differences compared with the reference criterion; therefore, the %BF output from these two devices should be interpreted with caution. The repeatability of each body composition device was supported by small CV ( < 3·0 %).

2019 ◽  
Vol 4 (2) ◽  
pp. 23 ◽  
Author(s):  
Antonio ◽  
Kenyon ◽  
Ellerbroek ◽  
Carson ◽  
Burgess ◽  
...  

The purpose of this investigation was to compare two different methods of assessing body composition (i.e., a multi-frequency bioelectrical impedance analysis (MF-BIA) and dual-energy x-ray absorptiometry (DXA)) over a four-week treatment period in exercise-trained men and women. Subjects were instructed to reduce their energy intake while maintaining the same exercise regimen for a period of four weeks. Pre and post assessments for body composition (i.e., fat-free mass, fat mass, percent body fat) were determined via the MF-BIA and DXA. On average, subjects reduced their energy intake by ~18 percent. The MF-BIA underestimated fat mass and percentage body fat and overestimated fat-free mass in comparison to the DXA. However, when assessing the change in fat mass, fat-free mass or percent body fat, there were no statistically significant differences between the MF-BIA vs. DXA. Overall, the change in percent body fat using the DXA vs. the MF-BIA was −1.3 ± 0.9 and −1.4 ± 1.8, respectively. Our data suggest that when tracking body composition over a period of four weeks, the MF-BIA may be a viable alternative to the DXA in exercise-trained men and women.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 1432.2-1432
Author(s):  
N. Toroptsova ◽  
O. Dobrovolskaya ◽  
N. Demin ◽  
L. Shornikova

Background:Rheumatoid arthritis (RA) is a complex inflammatory disease that modifies body composition. Using the dual-energy x-ray absorptiometry (DXA) in RA patients could be a method for body composition changes detection.Objectives:To study the body composition using DXA in patients with RA.Methods:The study involved 79 women with RA, median age 60 [55; 65] years. The bone mineral density (BMD) was measured by dual-energy x-ray absorptiometry using «Discovery A» (Hologic, USA). Assessment of body composition was carried out, using the program «Whole body». Sarcopenia (SP) was diagnosed as a decrease in appendicular mass index (AMI) <6.0 kg/m2. Osteoporosis (OP) was diagnosed as a decrease in T-score <-2.5 SD. Osteosarcopenia was determined when T-score was <-1.0 SD, AMI was <6.0 kg/m2, osteosarcopenic obesity - T-score was <-1.0 SD, AMI was <6.0 kg/m2and total fat was >35%.Results:The mean duration of RA was 9 [3; 11] years. The mean body mass index (BMI) was 27.6±4.8 kg/m2. Disease activity score in 28 joints-erythrocyte sedimentation rate was 4.5±1.3 points for the group. 39 (49.3%) patients used oral glucocorticoids continuously. Appendicular muscle mass and AMI were on average 17.8±3.0 kg and 6.8±1.0 kg/m2, respectively. AMI <6 kg/m2was detected in 20 (25.3%) patients. 56 (70.9%) women with RA had total fat > 35%, while only 22 (27.8%) of women with RA had obesity according to BMI (BMI >30 kg/m2). Isolated OP was found in 13 (16.5%), osteosarcopenia in 7 (8.9%) and osteosarcopenic obesity in 13 (16.5%) patients RA. No cases with isolated sarcopenia or sarcopenic obesity were detected. Only 3 (3.8%) patients did not have appendicular muscle mass, AMI and BMD decrease and overfat or obesity.Conclusion:About 97% women with RA had abnormal body composition phenotype: 16,5% - OP, 8.9% -osteosarcopenia, 16,5% - osteosarcopenic obesity and 54,4% - overfat.Disclosure of Interests:None declared


2006 ◽  
Vol 16 (3) ◽  
pp. 281-295 ◽  
Author(s):  
Heidi L. Petersen ◽  
C. Ted Peterson ◽  
Manju B. Reddy ◽  
Kathy B. Hanson ◽  
James H. Swain ◽  
...  

This study determined the effect of training on body composition, dietary intake, and iron status of eumenorrheic female collegiate swimmers (n = 18) and divers (n = 6) preseason and after 16 wk of training. Athletes trained on dryland (resistance, strength, fexibility) 3 d/wk, 1.5 h/d and in-water 6 d/wk, nine, 2-h sessions per week (6400 to 10,000 kJ/d). Body-mass index (kg/m2; P = 0.05), waist and hip circumferences (P ≤ 0.0001), whole body fat mass (P = 0.0002), and percentage body fat (P ≤ 0.0001) decreased, whereas lean mass increased (P = 0.028). Using dual-energy X-ray absorptiometry, we found no change in regional lean mass, but fat decreased at the waist (P = 0.0002), hip (P = 0.0002), and thigh (P = 0.002). Energy intake (10,061 ± 3617 kJ/d) did not change, but dietary quality improved with training, as refected by increased intakes of fber (P = 0.036), iron (P = 0.015), vitamin C (P = 0.029), vitamin B-6 (P = 0.032), and fruit (P = 0.003). Iron status improved as refected by slight increases in hemoglobin (P = 0.046) and hematocrit (P = 0.014) and decreases in serum transferrin receptor (P ≤ 0.0001). Studies are needed to further evaluate body composition and iron status in relation to dietary intake in female swimmers.


2020 ◽  
Vol 23 (3) ◽  
pp. 443-450 ◽  
Author(s):  
Cherilyn N. McLester ◽  
Brett S. Nickerson ◽  
Brian M. Kliszczewicz ◽  
John R. McLester

2010 ◽  
Vol 55 (9) ◽  
pp. 2619-2635 ◽  
Author(s):  
ZiMian Wang ◽  
Steven B Heymsfield ◽  
Zhao Chen ◽  
Shankuan Zhu ◽  
Richard N Pierson

2011 ◽  
Vol 106 (S1) ◽  
pp. S57-S59 ◽  
Author(s):  
Kathryn E. Michel ◽  
Wendy Anderson ◽  
Carolyn Cupp ◽  
Dorothy P. Laflamme

Body condition scoring (BCS) systems primarily assess body fat. Both overweight and underweight animals may have loss of lean tissue that may not be noted using standard BCS systems. Catabolism of lean tissue can occur rapidly, may account for a disproportionate amount of body mass loss in sick cats and can have deleterious consequences for outcome. Therefore, along with evaluation of body fat, patients should undergo evaluation of muscle mass. The aims of the present study were first to evaluate the repeatability and reproducibility of a 4-point feline muscle mass scoring (MMS) system and second to assess the convergent validity of MMS by dual-energy X-ray absorptiometry (DXA). MMS was as follows: 3, normal muscle mass; 2, slight wasting; 1, moderate wasting; 0, severe wasting. For the first aim, forty-four cats were selected for evaluation based on age and BCS, and for the second aim, thirty-three cats were selected based on age, BCS and MMS. Cats were scored by ten different evaluators on three separate occasions. Body composition was determined by DXA. Inter- and intra-rater agreement were assessed using kappa analysis. Correlation between MMS and BCS, age, percentage lean body mass and lean body mass (LBM) was determined using Spearman's rank-order correlation. The MMS showed moderate inter-rater agreement in cats that scored normal or severely wasted (κ = 0·48–0·53). Intra-rater agreement was substantial (κ = 0·71–0·73). The MMS was significantly correlated with BCS (r 0·76, P < 0·0001), age (r − 0·75, P < 0·0001), LBM (g) (r 0·62, P < 0·0001) and percentage LBM (r − 0·49, P < 0·0035). Additional investigation is needed to determine whether the MMS can be refined and to assess its clinical applicability.