Pollen-Shaped Hierarchical Structure for Pressure Sensors with High Sensitivity in an Ultrabroad Linear Response Range

2020 ◽  
Vol 12 (49) ◽  
pp. 55362-55371
Author(s):  
Tingting Zhao ◽  
Li Yuan ◽  
Tongkuai Li ◽  
Longlong Chen ◽  
Xifeng Li ◽  
...  
1993 ◽  
Vol 5 (2) ◽  
pp. 113-120 ◽  
Author(s):  
Wojciech Matuszewski ◽  
Marek Trojanowicz ◽  
Mark E. Meyerhoff ◽  
Anna Moszczyńska ◽  
Elzbieta Lange-Moroz

2017 ◽  
Vol 88 (8) ◽  
pp. 083115 ◽  
Author(s):  
Kuan Ren ◽  
Tao Xu ◽  
Jianhua Zheng ◽  
Jianjun Dong ◽  
Minxi Wei ◽  
...  

2016 ◽  
Vol 94 (11) ◽  
pp. 969-975 ◽  
Author(s):  
Wei Li ◽  
Nathan W. Kuehne ◽  
Erin Dallin ◽  
Reuven Gordon ◽  
Fraser Hof

Acetyl amantadine (AcAm) is produced from amantadine (Am) in vivo upon catalysis by spermidine/spermine N1-acetyl transferase (SSAT). SSAT is a biomarker for multiple aggressive cancers, and the analysis of AcAm in urine has been promoted as a proxy measure for the early detection of cancer. We report here the development and optimization of cucurbit[7]uril–dye pair based indicator displacement assay (IDA) for the detection of AcAm in solution. In deionized water, using Rhodamine B as the dye, the limit of detection of AcAm was 0.087 μM with a linear response range from 0 to 1 μM. Using berberine as the dye, the limit of detection was 0.077 μM with the same range of linear response. Our efforts and difficulties in translating this assay to function in human urine are also described. We achieve a partial response of the berberine IDA to the presence of AcAm in urine that has undergone a simple PD-10 desalting step.


2021 ◽  
Vol 7 (52) ◽  
Author(s):  
Min Cai ◽  
Zhongdong Jiao ◽  
Shuang Nie ◽  
Chengjun Wang ◽  
Jun Zou ◽  
...  

2020 ◽  
Vol 11 (1) ◽  
Author(s):  
Ningning Bai ◽  
Liu Wang ◽  
Qi Wang ◽  
Jue Deng ◽  
Yan Wang ◽  
...  

AbstractSensitivity is a crucial parameter for flexible pressure sensors and electronic skins. While introducing microstructures (e.g., micro-pyramids) can effectively improve the sensitivity, it in turn leads to a limited pressure-response range due to the poor structural compressibility. Here, we report a strategy of engineering intrafillable microstructures that can significantly boost the sensitivity while simultaneously broadening the pressure responding range. Such intrafillable microstructures feature undercuts and grooves that accommodate deformed surface microstructures, effectively enhancing the structural compressibility and the pressure-response range. The intrafillable iontronic sensor exhibits an unprecedentedly high sensitivity (Smin > 220 kPa−1) over a broad pressure regime (0.08 Pa-360 kPa), and an ultrahigh pressure resolution (18 Pa or 0.0056%) over the full pressure range, together with remarkable mechanical stability. The intrafillable structure is a general design expected to be applied to other types of sensors to achieve a broader pressure-response range and a higher sensitivity.


Sign in / Sign up

Export Citation Format

Share Document