Screening effectiveness of the Minnesota Child Development Inventory expressive and receptive language scales: Sensitivity, specificity, and predictive value.

1990 ◽  
Vol 2 (1) ◽  
pp. 80-85 ◽  
Author(s):  
C. Anne Chaffee ◽  
Charles E. Cunningham ◽  
Margaret Secord-Gilbert ◽  
Heather Elbard ◽  
et al
1989 ◽  
Vol 54 (1) ◽  
pp. 101-105 ◽  
Author(s):  
J. Bruce Tomblin ◽  
Cynthia M. Shonrock ◽  
James C. Hardy

The extent to which the Minnesota Child Development Inventory (MCDI), could be used to estimate levels of language development in 2-year-old children was examined. Fifty-seven children between 23 and 28 months were given the Sequenced Inventory of Communication Development (SICD), and at the same time a parent completed the MCDI. In addition the mean length of utterance (MLU) was obtained for each child from a spontaneous speech sample. The MCDI Expressive Language scale was found to be a strong predictor of both the SICD Expressive scale and MLU. The MCDI Comprehension-Conceptual scale, presumably a receptive language measure, was moderately correlated with the SICD Receptive scale; however, it was also strongly correlated with the expressive measures. These results demonstrated that the Expressive Language scale of the MCDI was a valid predictor of expressive language for 2-year-old children. The MCDI Comprehension-Conceptual scale appeared to assess both receptive and expressive language, thus complicating its interpretation.


2012 ◽  
Vol 52 (1) ◽  
pp. 6
Author(s):  
Syahperlan Wendi Simangunsong ◽  
Soeroyo Machfudz ◽  
Mei Neni Sitaresmi

Background Early stimulation, detection and intervention areimportant for child development and are recommended in theearly years of childhood for optimal results. The Indonesianchild development pre-screening questionnaire, Kuesioner PraSkrining Perkembangan (KPSP), has been widely used in publichealth centers (PHC) and community health centers (CHC)in the country. Howevei; the accuracy of this test has not beenadequately assessed.Objective To assess the diagnostic value of KPSP as a prescreeningtool for child development compared to that of theDenver II developmental screening test.Methods We conducted a KPSP diagnostic study, using theDenver II test as a gold standard for comparison. Subjects werechildren aged 3 to 60 months. They were recruited from one ofthree settings: hospital, community (child care centers) or schools(kindergarten).Results Of 210 children recruited, 182 were included in ourstudy. The overall sensitivity, specificity, positive predictive value(PPV), negative predictive value (NPV) and accuracy of KPSPwere 68.8%, 86.6%, 64.7%, 88.6% and 81.9%, respectively. Thecomparison of diagnostic value based on age groups showed betterresults in the 3 - 24 month group than that of the older group.Sensitivity, specificity and accuracy of the younger group vs. theolder group were 92.3% vs. 60.0%, 78.6% vs. 87.5% and 85.2%vs. 81.3%, respectively.Conclusion The accuracy of KPSP compared to Denver II testwas good for the 3 - 24 month age group. However, this toolshould be revised for the older age group. [Paediatr lndones.2012;52:6-9].


2012 ◽  
Vol 15 (1) ◽  
pp. 12 ◽  
Author(s):  
Levent Sahiner ◽  
Ali Oto ◽  
Kudret Aytemir ◽  
Tuncay Hazirolan ◽  
Musturay Karcaaltincaba ◽  
...  

<p><b>Background:</b> The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).</p><p><b>Methods:</b> Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.</p><p><b>Results:</b> Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.</p><p><b>Conclusion:</b> Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.</p>


2018 ◽  
Vol 1 ◽  
pp. 9
Author(s):  
Harshad Arvind Vanjare ◽  
Jyoti Panwar

Objective The objective of the study was to assess the accuracy of ultrasound examination for the diagnosis of rotator cuff tear and tendinosis performed by a short experienced operator, compared to magnetic resonance imaging (MRI) results. Method A total of 70 subjects suspected to have rotator cuff tear or tendinosis and planned for shoulder MRI were included in the study. Shoulder ultrasound was performed either before or after the MRI scan on the same day. Ultrasound operator had a short experience in performing an ultrasound of the shoulder. Ultrasound findings were correlated to MRI findings. Results Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for the diagnosis of tendinosis were 58%, 84%, 63%, 80%, and 75%, respectively, and it was 68%, 91%, 73%, 88%, and 85%, respectively, for the diagnosis of rotator cuff tear. Conclusions Sensitivity for diagnosing rotator cuff tear or tendinosis was moderate but had a higher negative predictive value. Thus, the ultrasound operator with a short experience in performing shoulder ultrasound had moderate sensitivity in diagnosing tendinosis or tears; however, could exclude them with confidence.


2017 ◽  
pp. 59-63
Author(s):  
Thanh Hung Dieu ◽  
Anh Vu Nguyen

Objects: We assessed the ability of ST-segment elevation in lead aVR to predict left main and/or 3-vessel disease (LM/3VD) in patients with acute coronary syndromes (ACS). Meterial and Method: 410 patients with ACS, who underwent coronary angiography, were evaluated. Results: 131 (31.9%) patients have been LM/3VD. ST segment elevation > 0.05 mV in leads aVR have been an independent predictor LM/3VD with sensitivity, specificity, positive predictive value PPV) and negative predictive value (NPV) 74.0%, 78.1%, 61.4% and 86.5%, respectively (p<0.001). ST segment elevation > 0.05 mV in leads aVR with ST segment depression in leads V4-V6 have related LM/3VD with sensitivity, specificity, PPV and NPV 44.3%, 92.8%, 74.4% and 75.2%, respectively (p<0.001). ST segment elevation > 0.1 mV in leads aVR have related LM/3VD with sensitivity, specificity, PPV and NPV 51.9%, 87.1%, 65.1% and 79.4%, respectively (p<0.001). Conclusions: ST segment elevation > 0.05 mV in leads aVR have been an independent predictor LM/3VD in patients with ACS. Key words: Acute coronary syndromes, ST-segment elevation, aVR


2008 ◽  
Vol 47 (04) ◽  
pp. 163-166 ◽  
Author(s):  
D. Steiner ◽  
S. Laurich ◽  
R. Bauer ◽  
J. Kordelle ◽  
R. Klett

SummaryIn not infected knee prostheses bone scintigraphy is a possible method to diagnose mechanical loosening, and therefore, to affect treatment regimes in symptomatic patients. However, hitherto studies showed controversial results for the reliability of bone scintigraphy in diagnosing loosened knee prostheses by using asymptomatic control groups. Therefore, the aim of our study was to optimize the interpretation procedure and to evaluate the accuracy using results from revision surgery as standard. Methods: Retrospectively, we were able to examine the tibial component in 31 cemented prostheses. In this prostheses infection was excluded by histological or bacteriological examination during revision surgery. To quantify bone scintigraphy, we used medial and lateral tibial regions with a reference region from the contralateral femur. Results: To differentiate between loosened and intact prostheses we found a threshold of 5.0 for the maximum tibia to femur ratio of the both tibial regions and a threshold of 18% for the difference of the ratio of both tibial regions. Using these thresholds, values of 0.9, 1, 0.85, 1, and 0.94 were calculated for sensitivity, specificity, negative predictive value, positive predictive value, and accuracy, respectively. To get a sensitivity of 1, we found a lower threshold of 3.3 for the maximum tibia to femur ratio. Conclusion: Quantitative bone scintigraphy appears to be a reliable diagnostic tool for aseptic loosening of knee prostheses with thresholds evaluated by revision surgery results being the golden standard.


2020 ◽  
Vol 103 (6) ◽  
pp. 585-593

Objective: To evaluate the accuracy of transvaginal ultrasonography (TVS) and saline infusion sonography (SIS) in use for the diagnosis of endometrial polyps and submucous myoma compared to hysteroscopy. Histopathology was considered as the gold standard for final diagnosis. Materials and Methods: The present retrospective study was conducted at Bhumibol Adulyadej Hospital, Bangkok, Thailand between January 2014 and December 2017. Medical records of 150 patients who attended for hysteroscopy and histopathological diagnosis were reviewed. The accuracy of TVS and SIS for the diagnosis of endometrial polyps and submucous myoma were determined. Results: Out of 150 enrolled cases, endometrial polyp was the most frequent hysteroscopic finding in participants of the present study (92/150). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of TVS, SIS, and hysteroscopy compared to pathologic reports for detection endometrial polyps were 71.7% versus 93.5% versus 97.8%, 38.5% versus 52.2% versus 68.2%, 80.5% versus 88.7% versus 92.8%, 27.8% versus 66.7% versus 88.2%, and 64.4% versus 85.2% versus 92.1%, respectively. The sensitivity, specificity, PPV, NPV, and accuracy of TVS, SIS, and hysteroscopy for detection of submucous myoma were 81.6% versus 92.1% versus 94.7%, 66.7% versus 86.9% versus 100%, 77.5% versus 92.1% versus 100%, 72.0% versus 86.9% versus 90.9%, and 75.4% versus 90.2% versus 96.6%, respectively. The kappa value from TVS, SIS, and hysteroscopy when the histopathologic reports were overall intrauterine abnormalities, endometrial polyps and submucous myoma were 0.45/0.43/0.72, 0.77/0.76/0.89, and 0.92/0.92/1.00, respectively. Conclusion: Sensitivity, specificity, PPV, NPV, accuracy, and kappa value of SIS for detecting endometrial polyps and submucous myoma were better than TVS. Keywords: Ultrasonography, Saline infusion sonography, Hysteroscopy, Accuracy


2020 ◽  
Vol 08 (11) ◽  
pp. E1623-E1632
Author(s):  
Carlos Robles-Medranda ◽  
Roberto Oleas ◽  
Miguel Puga-Tejada ◽  
Manuel Valero ◽  
Raquel Del Valle ◽  
...  

Abstract Background and study aims Assessment of endoscopic ultrasonography (EUS)-elastography of the liver and spleen may identify patients with portal hypertension secondary to chronic liver disease. We aimed to evaluate use of EUS-elastography of the liver and spleen in identification of portal hypertension in patients with chronic liver disease. Patients and methods This was a single-center, diagnostic cohort study. Consecutive patients with liver cirrhosis and portal hypertension underwent EUS-elastography of the liver and spleen. Patients without a history of liver disease were enrolled as controls. The primary outcome was diagnostic yield of liver and spleen stiffness measurement via EUS-elastography in prediction of portal hypertension secondary to chronic liver cirrhosis. Cutoff values were defined through Youden’s index. Overall accuracy was calculated for parameters with an area under the receiver operating characteristic (AUROC) curve ≥ 80 %. Results Among the 61 patients included, 32 had cirrhosis of the liver. Liver and spleen stiffness was measured by the strain ratio and strain histogram, with sensitivity/(1 − specificity) AUROC values ≥ 80 %. For identification of patients with cirrhosis and portal hypertension, the liver strain ratio (SR) had a sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 84.3 %, 82.8 %, 84.4 %, and 82.8 %, respectively; the liver strain histogram (SH) had values of 87.5 %, 69.0 %, 75.7 %, and 83.3 %, respectively. EUS elastography of the spleen via the SR reached a sensitivity, specificity, PPV, and NPV of 87.5 %, 69.0 %, 75.7 %, and 83.3 %, respectively, whereas the values of SH were 56.3 %, 89.7 %, 85.7 %, and 65.0 %, respectively. Conclusion Endoscopic ultrasonographic elastography of the liver and spleen is useful for diagnosis of portal hypertension in patients with cirrhosis.


2021 ◽  
pp. 095646242110222
Author(s):  
Thomas Juniper ◽  
Chris P Eades ◽  
Eliza Gil ◽  
Harriet Fodder ◽  
Killian Quinn ◽  
...  

Objectives: An elevated serum (1-3)-β-D-glucan (BDG) concentration has high sensitivity for a diagnosis of Pneumocystis pneumonia (PCP) in people with HIV (PWH). At the current manufacturer-recommended positive threshold of 80 pg/mL (Fungitell), specificity for PCP is variable and other diagnostic tests are required. We evaluated the utility of serum BDG for diagnosis of suspected PCP in PWH at three inner-London hospitals to determine BDG concentrations for diagnosis and exclusion of PCP. Methods: From clinical case records, we abstracted demographic and clinical information and categorised patients as having confirmed or probable PCP, or an alternative diagnosis. We calculated sensitivity, specificity and positive predictive value (PPV) of serum BDG concentrations >400 pg/mL and negative predictive value (NPV) of BDG <80 pg/mL. Results: 76 patients were included; 29 had laboratory-confirmed PCP, 17 had probable PCP and 30 had an alternative diagnosis. Serum BDG >400 pg/mL had a sensitivity of 83%, specificity of 97% and PPV 97% for diagnosis of PCP; BDG <80 pg/mL had 100% NPV for exclusion of PCP. Conclusions: In PWH with suspected PCP, BDG <80 pg/mL excludes a diagnosis of PCP, whereas BDG concentrations >400 pg/mL effectively confirm the diagnosis. Values 80–400 pg/mL should prompt additional diagnostic tests.


Sign in / Sign up

Export Citation Format

Share Document