scholarly journals A proof-of principal study using phase-contrast imaging for the detection of large airway pathologies after lung transplantation

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Stephan Umkehrer ◽  
Carmela Morrone ◽  
Julien Dinkel ◽  
Laura Aigner ◽  
Maximilian F. Reiser ◽  
...  

Abstract In this study we aim to evaluate the assessment of bronchial pathologies in a murine model of lung transplantation with grating-based X-ray interferometry in vivo. Imaging was performed using a dedicated grating-based small-animal X-ray dark-field and phase-contrast scanner. While the contrast modality of the dark-field signal already showed several promising applications for diagnosing various types of pulmonary diseases, the phase-shifting contrast mechanism of the phase contrast has not yet been evaluated in vivo. For this purpose, qualitative analysis of phase-contrast images was performed and revealed pathologies due to previous lung transplantation, such as unilateral bronchial stenosis or bronchial truncation. Dependent lung parenchyma showed a strong loss in dark-field and absorption signal intensity, possibly caused by several post transplantational pathologies such as atelectasis, pleural effusion, or pulmonary infiltrates. With this study, we are able to show that bronchial pathologies can be visualized in vivo using conventional X-ray imaging when phase-contrast information is analysed. Absorption and dark-field images can be used to quantify the severity of lack of ventilation in the affected lung.

2020 ◽  
Vol 27 (5) ◽  
pp. 1395-1414 ◽  
Author(s):  
Benedikt Günther ◽  
Regine Gradl ◽  
Christoph Jud ◽  
Elena Eggl ◽  
Juanjuan Huang ◽  
...  

Inverse Compton scattering provides means to generate low-divergence partially coherent quasi-monochromatic, i.e. synchrotron-like, X-ray radiation on a laboratory scale. This enables the transfer of synchrotron techniques into university or industrial environments. Here, the Munich Compact Light Source is presented, which is such a compact synchrotron radiation facility based on an inverse Compton X-ray source (ICS). The recent improvements of the ICS are reported first and then the various experimental techniques which are most suited to the ICS installed at the Technical University of Munich are reviewed. For the latter, a multipurpose X-ray application beamline with two end-stations was designed. The beamline's design and geometry are presented in detail including the different set-ups as well as the available detector options. Application examples of the classes of experiments that can be performed are summarized afterwards. Among them are dynamic in vivo respiratory imaging, propagation-based phase-contrast imaging, grating-based phase-contrast imaging, X-ray microtomography, K-edge subtraction imaging and X-ray spectroscopy. Finally, plans to upgrade the beamline in order to enhance its capabilities are discussed.


2019 ◽  
Vol 53 (9) ◽  
pp. 095401
Author(s):  
Norihito Matsunaga ◽  
Kazuhiro Yano ◽  
Marco Endrizzi ◽  
Alessandro Olivo

2021 ◽  
Vol 9 ◽  
Author(s):  
Siwei Tao ◽  
Congxiao He ◽  
Xiang Hao ◽  
Cuifang Kuang ◽  
Xu Liu

X-ray phase contrast imaging is a promising technique in X-ray biological microscopy, as it improves the contrast of images for materials with low electron density compared to traditional X-ray imaging. The spatial resolution is an important parameter to evaluate the image quality. In this paper, simulation of factors which may affect the spatial resolution in a typical 2D grating–based phase contrast imaging system is conducted. This simulation is based on scalar diffraction theory and the operator theory of imaging. Absorption, differential phase contrast, and dark-field images are retrieved via the Fourier transform method. Furthermore, the limitation of the grating-to-detector distance in the spatial harmonic method is discussed in detail.


2009 ◽  
Vol 105 (10) ◽  
pp. 102006 ◽  
Author(s):  
F. Pfeiffer ◽  
M. Bech ◽  
O. Bunk ◽  
T. Donath ◽  
B. Henrich ◽  
...  

2013 ◽  
Vol 3 (1) ◽  
Author(s):  
M. Bech ◽  
A. Tapfer ◽  
A. Velroyen ◽  
A. Yaroshenko ◽  
B. Pauwels ◽  
...  

2018 ◽  
Vol 4 (10) ◽  
pp. 113
Author(s):  
Simon Zabler

Very early, in 1896, Wilhelm Conrad Röntgen, the founding father of X-rays, attempted to measure diffraction and refraction by this new kind of radiation, in vain. Only 70 years later, these effects were measured by Ulrich Bonse and Michael Hart who used them to make full-field images of biological specimen, coining the term phase-contrast imaging. Yet, another 30 years passed until the Talbot effect was rediscovered for X-radiation, giving rise to a micrograting based interferometer, replacing the Bonse–Hart interferometer, which relied on a set of four Laue-crystals for beam splitting and interference. By merging the Lau-interferometer with this Talbot-interferometer, another ten years later, measuring X-ray refraction and X-ray scattering full-field and in cm-sized objects (as Röntgen had attempted 110 years earlier) became feasible in every X-ray laboratory around the world. Today, now that another twelve years have passed and we are approaching the 125th jubilee of Röntgen’s discovery, neither Laue-crystals nor microgratings are a necessity for sensing refraction and scattering by X-rays. Cardboard, steel wool, and sandpaper are sufficient for extracting these contrasts from transmission images, using the latest image reconstruction algorithms. This advancement and the ever rising number of applications for phase-contrast and dark-field imaging prove to what degree our understanding of imaging physics as well as signal processing have advanced since the advent of X-ray physics, in particular during the past two decades. The discovery of the electron, as well as the development of electron imaging technology, has accompanied X-ray physics closely along its path, both modalities exploring the applications of new dark-field contrast mechanisms these days. Materials science, life science, archeology, non-destructive testing, and medicine are the key faculties which have already integrated these new imaging devices, using their contrast mechanisms in full. This special issue “Phase-Contrast and Dark-field Imaging” gives us a broad yet very to-the-point glimpse of research and development which are currently taking place in this very active field. We find reviews, applications reports, and methodological papers of very high quality from various groups, most of which operate X-ray scanners which comprise these new imaging modalities.


2008 ◽  
Vol 2008 ◽  
pp. 1-8 ◽  
Author(s):  
Ming Jiang ◽  
Christopher Lee Wyatt ◽  
Ge Wang

X-ray imaging is of paramount importance for clinical and preclinical imaging but it is fundamentally restricted by the attenuation-based contrast mechanism, which has remained essentially the same since Roentgen's discovery a century ago. Recently, based on the Talbot effect, groundbreaking work was reported using 1D gratings for X-ray phase-contrast imaging with a hospital-grade X-ray tube instead of a synchrotron or microfocused source. In this paper, we report an extension using 2D gratings that reduces the imaging time and increases the accuracy and robustness of phase retrieval compared to current grating-based phase-contrast techniques. Feasibility is demonstrated via numerical simulation.


2021 ◽  
Author(s):  
Konstantin Willer ◽  
Alexander Fingerle ◽  
Wolfgang Noichl ◽  
Fabio De Marco ◽  
Manuela Frank ◽  
...  

SummaryBackgroundDiseases of the respiratory system are leading global causes of chronic morbidity and mortality. While advanced medical imaging technologies of today deliver detailed diagnostic information, a low-dose, fast, and inexpensive option for early detection and/or follow-ups is still lacking. Here, we report on the first human application of a novel modality, namely X-ray dark-field chest imaging, which might fill this gap. Enabling the assessment of microstructural changes in lung parenchyma, this technique presents a more sensitive alternative to conventional chest X-rays, and yet requires only a fraction of the dose applied in computed tomography (CT).MethodsFor this first clinical evaluation, we have built a novel dark-field chest X-ray system, which is also capable of simultaneously acquiring a conventional thorax radiograph (7 seconds, 0·035 mSv effective dose). Representing a major medical condition, we selected chronic obstructive pulmonary disease as study subject to obtain a first impression of potential diagnostic benefits relevant to humans. For a collective of 77 patients with different disease stages, X-ray dark-field- and CT-images were acquired and visually assessed by 5 readers. In addition, pulmonary function tests were performed for every patient. The individual data sets were evaluated in a statistical work-up using correlation testing, rank-based analysis of variance, and pair-wise post-hoc comparison.FindingsCompared to CT-based parameters (quantitative emphysema: ρ=–0·27, p=0·0893 and visual emphysema: ρ=–0·45, p=0·0028), the dark-field signal (ρ=0·62, p<0·0001) yields a stronger correlation with diffusion capacity in the evaluated collective. Emphysema assessment based on dark-field chest X-ray features yields consistent conclusions with findings from visual CT image interpretation and shows improved diagnostic performance in comparison to conventional clinical tests characterizing emphysema.InterpretationX-ray dark-field chest imaging allows the diagnosis of pulmonary emphysema as it provides relevant information representing the structural condition of lung parenchyma. Significant diagnostic benefits are also expected for other lung disorders.FundingEuropean Research Council, Royal Philips, Karlsruhe Nano Micro Facility.Research in contextEvidence before this studyWith a rising number of examinations in the last decades, X-rays play an indispensable role in clinical routine. Contrast formation in medical X-ray imaging such as radiography, fluoroscopy, and computed tomography is based on attenuation, which generally benefits from large differences in atomic number and/or mass density between involved materials. If these conditions are not prevalent, or the resolution of the imaging system is not sufficient, diagnostic capabilities are limited. However, attenuation is not the only physical effect X-rays are subjected to when penetrating matter. Variations in an object’s electron density lead to refraction and coherent small-angle scattering of incident X-rays. Phase-sensitive imaging techniques can detect these wave-optical phenomena, yielding additional object information. The dark-field signal, being a function of small-angle scattering, can provide structural information on the micron scale, generally below the resolution limit of the imaging system. Due to their very stringent requirements to X-ray source coherence, these techniques were originally limited to large-scale synchrotron facilities. The proposal of a three-grating interferometer in 2006, however, enabled the use of low-brilliance sources for X-ray phase-contrast imaging and thereby paved the way into the clinics. Such an apparatus elegantly allows the simultaneous acquisition of the conventional attenuation, differential phase-contrast, and novel dark-field signals. In a compact table-top system suitable for investigating murine disease models, numerous studies on pulmonary disorders such as chronic obstructive pulmonary disease (COPD), pulmonary fibrosis, pneumothorax, ventilator-associated lung injury, lung cancer, and pneumonia have been conducted and demonstrated a broad diagnostic value of the dark-field modality in particular. Adapting the system to enable imaging of the human body is a technical challenge due to limitations of the micrometer-fine, high aspect ratio grating structures in terms of fabricable size and performance at clinically relevant X-ray energies. The first evidences that these limitations are manageable were delivered in 2017 and 2018 by in-vivo porcine and human cadaver studies with an experimental prototype system.Added value of this studyWith this work we present the first X-ray dark-field chest images of human subjects in-vivo and demonstrate the method’s feasibility in a clinical surrounding. To enable this study, we have conceived, constructed, and commissioned a custom-built first demonstrator system suitable for patient use. This includes satisfying clinical demands regarding safety, usability, acquisition time, radiation dose, field of view, and image quality. This study marks the transition from investigating artificially induced disease models to evaluating the modality’s actual diagnostic performance in patients.Implications of all available evidenceOur findings indicate that X-ray dark-field radiography provides image-type information of the lungs’ underlying microstructure in humans. In view of the strong link between alveolar structure and the functional condition of the lung, this capability is highly relevant for respiratory medicine and might help to establish a better understanding of pulmonary disorders. With regard to early detection of COPD, which is generally accompanied by structural impairments of the lung, this novel technique might support resolving the prevalent under-diagnosis reported in literature. With an effective dose significantly lower (about a factor of hundred) compared to thorax computed tomography, dark-field radiography could be used as broadly deployed screening tool.


Author(s):  
S. W. Wilkins ◽  
Ya. I. Nesterets ◽  
T. E. Gureyev ◽  
S. C. Mayo ◽  
A. Pogany ◽  
...  

This review provides a brief overview, albeit from a somewhat personal perspective, of the evolution and key features of various hard X-ray phase-contrast imaging (PCI) methods of current interest in connection with translation to a wide range of imaging applications. Although such methods have already found wide-ranging applications using synchrotron sources, application to dynamic studies in a laboratory/clinical context, for example for in vivo imaging, has been slow due to the current limitations in the brilliance of compact laboratory sources and the availability of suitable high-performance X-ray detectors. On the theoretical side, promising new PCI methods are evolving which can record both components of the phase gradient in a single exposure and which can accept a relatively large spectral bandpass. In order to help to identify the most promising paths forward, we make some suggestions as to how the various PCI methods might be compared for performance with a particular view to identifying those which are the most efficient, given the fact that source performance is currently a key limiting factor on the improved performance and applicability of PCI systems, especially in the context of dynamic sample studies. The rapid ongoing development of both suitable improved sources and detectors gives strong encouragement to the view that hard X-ray PCI methods are poised for improved performance and an even wider range of applications in the near future.


2021 ◽  
Vol 7 (12) ◽  
pp. 249
Author(s):  
Zhi Qiao ◽  
Xianbo Shi ◽  
Michael Wojcik ◽  
Lahsen Assoufid

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.


Sign in / Sign up

Export Citation Format

Share Document