scholarly journals Environmentally persistent free radicals in indoor particulate matter, dust, and on surfaces

Author(s):  
Alexander Filippi ◽  
Roger Sheu ◽  
Thomas Berkemeier ◽  
Ulrich Pöschl ◽  
Haijie Tong ◽  
...  

Environmentally persistent free radicals (EPFR) are an emerging class of constituents in particulate matter (PM). They are relatively stable with lifetimes of days to years in the condensed phase, influence...

2021 ◽  
Vol 13 (15) ◽  
pp. 8263
Author(s):  
Marius Bodor

An important aspect of air pollution analysis consists of the varied presence of particulate matter in analyzed air samples. In this respect, the present work aims to present a case study regarding the evolution in time of quantified particulate matter of different sizes. This study is based on data acquisitioned in an indoor location, already used in a former particulate matter-related article; thus, it can be considered as a continuation of that study, with the general aim to demonstrate the necessity to expand the existing network for pollution monitoring. Besides particle matter quantification, a correlation of the obtained results is also presented against meteorological data acquisitioned by the National Air Quality Monitoring Network. The transformation of quantified PM data in mass per volume and a comparison with other results are also addressed.


2021 ◽  
pp. 111013
Author(s):  
Dong-Wook Lee ◽  
Jongmin Oh ◽  
Shinhee Ye ◽  
Youngrin Kwag ◽  
Wonho Yang ◽  
...  

2004 ◽  
Vol 61 (3) ◽  
Author(s):  
S. Nardini ◽  
R. Cagnin ◽  
G. Invernizzi ◽  
A. Ruprecht ◽  
R. Boffi ◽  
...  

Aim of the study: There are International and National standards that requires hospitals and health premises to be smoke-free. According to recent data from Italy and other European Countries, smoking is a widespread habit in hospitals. To get smoke-free hospitals in an Italian region, we have adopted the European Code for smoke-free hospitals, which sets standards and provides instruments for its implementation. According to the Code, whenever possible, each step towards a smoke-free hospital, should be shared by all staff. As a mean for achieving this goal, in our region the certification of single units as smoke-free units has been chosen. For getting the certification, besides implementing the Code, we planned to use ETS (Environmental Tobacco Smoke) monitoring, as ETS should not be present in hospitals. As a marker of ETS we have chosen Particulate Matter (PM), as it can easily be measured in real-time with a portable instrument and, when other - even outdoor - sources of combustion can be ruled out, it is an accurate detector of cigarette smoke. Here the first experience of measuring PM in hospitals for monitoring ETS and certificating smoke-free health premises, is described. Materials and methods: PM measurements were carried out without any previous notification in different areas of two Network hospitals of the Veneto Region, during a single working day. A real time laser-operated aerosol mass analyser was used. Several classes of PM (PM1, PM2.5, PM7, PM10, TSP Total Suspended Particles) were measured. Results: Outdoor PM levels were found to be repeatedly lower than the annual official limits of 65 mcg/m3 and around the 24 hour official limits of 15 mcg/m3 [15 to 20 mcg/m3, with an overall mean (±SD) of 17.8 (1.9)] throughout the whole day. Very good indoor air quality was found in the operating theaters and isolation department, where PM2.5 concentrations were much lower than outdoor levels [1.6 (0.9) and 5.9 (0.6) mcg/m3, respectively]. No increase in PM pollution was found in the surveyed medical offices, halls and waiting rooms where smoking was positively forbidden [PM2.5 concentrations of 14.8 (2.2) and 12.9 (1.1) mcg/m3] except in a medical office and in two coffee rooms for staff only where high PM levels were recorded [PM2.5 58.7 (29.1), 27.0 (10.6) and 107.1 (47.8) mcg/m3] and an offence of smoking restrictions could be proved. Conclusions: The measurement of PM in hospital for monitoring ETS proved to be both feasible and sensible. PM measurements with a portable instrument can be used both for controlling the compliance with rules or chosen standards and for educating staff about smoking related hazards, thus gaining consensus for the implementation of the tobacco control policy. In our experience, PM measurement can be used as an aid inside all actions designed by the European Code for smoke-free hospitals.


2020 ◽  
Vol 8 (2) ◽  
pp. 61-67
Author(s):  
Nurul Bahiyah Abd Wahid ◽  
Intan Idura Mohamad Isa ◽  
Ahmad Khairuddin Hassan ◽  
Muhammad Izzat Iman Razali ◽  
Ahmad Haziq Hasrizal ◽  
...  

This study aims to determine the particulate matter (PM2.5) mass concentrations and the comfort parameters (total bacterial counts (TBC), total fungal counts (TFC), relative humidity and temperature) in a university building. The samplings were carried out in three different indoor areas, including lecture hall, laboratory and lecturer office. PM2.5 samples were collected over a period of 8 h sampling using a low volume sampler (LVS). The anemometer Model Kestrel 0855YEL was used to measure relative humidity and temperature parameters. The sampling of airborne microorganisms was conducted by using microbial sampler at 350 L air sampled volume. The results showed that the highest average of PM2.5 was at lecture hall (88.54 ± 26.21 µgm-3) followed by lecturer office (69.79 ± 19.06 µgm-3) and laboratory (47.92 ± 24.88 µgm-3). The mean of TBC and TFC readings recorded as follow; 32.71 ± 5.91 cfu m-3 and 76.71 ± 21.5 cfu m-3 for laboratory, 112.1 ± 29.06 cfu m-3 and 124.67 ± 23.35 cfu m-3 for lecturer office, 121.74 ± 19.33 cfu m-3 and 115.33 ± 8.08 cfu m-3 for lecture hall. The average of all comfort parameter was within the prescribed standard by Industry Code of Practice on Indoor Air Quality 2010 for all sampling sites. Therefore, all occupants of the building can work in a conducive and comfortable environment. This study is in line with the objectives of National Policy on the Environment (DASN), which focusing on achieving a clean, safe, healthy and productive environment for present and future generations.


2021 ◽  
Author(s):  
Vito A Ilacqua ◽  
Nicole Scharko ◽  
Jordan Zambrana ◽  
Daniel Malashock

We surveyed literature on measurements of indoor particulate matter in all size fractions, in residential environments free of solid fuel combustion. Data from worldwide studies from 1990-2019 were assembled into the most comprehensive collection to date. Out of 2,752 publications retrieved, 538 articles from 433 research projects met inclusion criteria and reported unique data, from which more than 2,000 unique sets of indoor PM measurements were collected. Distributions of mean concentrations were compiled, weighted by study size. Long-term trends, the impact of non-smoking, air cleaners, and the influence of outdoor PM were also evaluated. Similar patterns of indoor PM distributions for North America and Europe could reflect similarities in the indoor environments of these regions. Greater observed variability for all regions of Asia may reflect greater heterogeneity in indoor conditions, but also low numbers of studies for some regions. Indoor PM concentrations of all size fractions were mostly stable over the survey period, with the exception of observed declines in PM2.5 in European and North American studies, and in PM10 in North America. While outdoor concentrations were correlated with indoor concentrations across studies, indoor concentrations had higher variability, illustrating a limitation of using outdoor measurements to approximate indoor PM exposures.


2021 ◽  
Author(s):  
SHRAVAN KUMAR ◽  
Manish Kumar Jain

Abstract Women spend relatively more time in indoor conditions in developing countries. Exposure to various indoor air pollutants leads them to higher health risks according to Household air quality in which they reside. Particulate matter (PM) exposure with their exposure duration inside the household plays a significant role in women's Respiratory problems. We measured size segregated particulate matter concentrations in 63 residences at different locations. Respiratory dust depositions (RDDs) for 118 women in their different respiratory regions like head-airway (HD), tracheobronchial (TB), and alveolar (AL) region for the three PM size fractions (PM10, PM2.5 & PM1) were investigated. For different positions like Light exercise and the Sitting condition, RDD values found for AL region was 0.091 µgmin− 1 (SD: 0.067, 0.012–0.408) and 0.028 µgmin− 1 (SD: 0.021, 0.003–0.126) for PM10, 0.325 µgmin− 1 (SD: 0.254, 0.053–1.521) and 0.183 µgmin− 1 (SD: 0.143, 0.031–0.857) for PM2.5, 0.257 µgmin− 1 (SD: 0.197, 0.043–1.04) and 0.057 µgmin− 1 (SD: 0.044, 0.009–0.233) respectively for PM1 to females. RDDs values in the AL region significantly increases as PM10 (11%), PM2.5 (68%), and PM1 (21%), confirm that for women, the AL region is the most prominent affected zone by fine particles (PM2.5).


Sign in / Sign up

Export Citation Format

Share Document