Experimental evaluation of a new apical access and closure device

2012 ◽  
Vol 60 (S 01) ◽  
Author(s):  
J Blumenstein ◽  
A Van Linden ◽  
J Kempfert ◽  
M Arsalan ◽  
H Möllmann ◽  
...  
2012 ◽  
Vol 94 (5) ◽  
pp. 1706-1709 ◽  
Author(s):  
Johannes Blumenstein ◽  
Arnaud Van Linden ◽  
Mani Arsalan ◽  
Sandra Voss ◽  
Helge Moellmann ◽  
...  

VASA ◽  
2004 ◽  
Vol 33 (2) ◽  
pp. 78-81 ◽  
Author(s):  
Thalhammer ◽  
Aschwanden ◽  
Jeanneret ◽  
Labs ◽  
Jäger

Background: Haemostatic puncture closure devices for rapid and effective hemostasis after arterial catheterisation are a comfortable alternative to manual compression. Implanting a collagen plug against the vessel wall may become responsible for other kind of vascular injuries i.e. thrombotic or stenotic lesions and peripheral embolisation. The aim of this paper is to report our clinically relevant vascular complications after Angio-Seal® and to discuss the results in the light of the current literature. Patients and methods: We report the symptomatic vascular complications in 17 of 7376 patients undergoing diagnostic or therapeutic catheterisation between May 2000 and March 2003 at the University Hospital Basel. Results: Most patients presented with ischaemic symptoms, arterial stenoses or occlusions and thrombotic lesions (n = 14), whereas pseudoaneurysms were extremely rare (n = 3). Most patients with ischaemic lesions underwent vascular surgery and all patients with a pseudoaneurysm were successfully treated by ultrasound-guided compression. Conclusions: Severe vascular complications after Angio-Seal® are rare, consistent with the current literature. There may be a shift from pseudoaneurysms to ischaemic lesions.


VASA ◽  
2018 ◽  
Vol 47 (2) ◽  
pp. 119-124 ◽  
Author(s):  
Artur I. Milnerowicz ◽  
Aleksandra A. Milnerowicz ◽  
Marcin Protasiewicz ◽  
Wiktor Kuliczkowski

Abstract. Background: Effectiveness of vascular closure devices during endovascular procedures requiring a direct puncture of a vascular prosthesis placed in the inguinal region is unknown. Patients and methods: The retrospective analysis included 134 patients with a history of polyethylene terephthalate (PETE) graft implantation in the inguinal region. In 20 (15 %) patients, haemostasis was achieved with manual compression, in 21 (16 %) with the StarClose™, and in 93 (69 %) with the AngioSeal™ device. Results: The incidence of vascular complications in the manual compression group was higher (at a threshold of statistical significance) than in the device closure group (45.0 vs. 24.5 %, p = 0.059). The difference was considered statistically significant when manual compression was compared with the AngioSeal™ closure group (45.0 vs. 13.9 %, p < 0.01). The vascular complication rate in the StarClose™ group was significantly higher than in the AngioSeal™ group (71.4 vs. 13.9 %, p < 0.000001). While haematomas were the only vascular complications observed after application of AngioSeal™, both haematomas and pseudoaneurysms were found in the StarClose™ group. Conclusions: The AngioSeal™ vascular closure device provides better local haemostasis than the StarClose™ device or manual compression during endovascular interventions requiring a direct puncture of PETE grafts


VASA ◽  
2013 ◽  
Vol 42 (2) ◽  
pp. 144-148 ◽  
Author(s):  
Daniel Maxien ◽  
Barbara Behrends ◽  
Karla M. Eberhardt ◽  
Tobias Saam ◽  
Sven F. Thieme ◽  
...  

2012 ◽  
Author(s):  
Chris Ste-Croix ◽  
David Tack ◽  
Denis Boucher ◽  
Francois Ruel ◽  
Gilles Pageau ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document