Scientific and Standardization Committee Communications Comparison of Test Methods for the Lupus Anticoagulant: International Survey on Lupus Anticoagulants-I (ISLA-1)

1990 ◽  
Vol 64 (03) ◽  
pp. 478-484 ◽  
Author(s):  
Thomas Exner ◽  
Douglas A Triplett ◽  
David A Taberner ◽  
Margaret A Howard ◽  
E Nigel Harris

SummarySix lyophilized plasma samples were sent to 20 “expert” laboratories for assessment of lupus anticoagulant (LA). Four samples contained pooled LA of graded potency mixed with aged normal plasma. One contained LA plus cephalin phospholipid and one contained a nonspecific venom anticoagulant. Sixteen methods were used overall with some participants using up to 8 methods. Results were scored in regard to the known potencies of LA in the samples and other known induced defects.Activated partial thromboplastin time (APTT) tests used by most participants for preliminary screening were relatively sensitive, but non-specific. Platelet or phospholipid neutralization procedures (PNP) appeared to be sensitive and specific but showed a non-linear response to increased LA content. Kaolin clotting time (KCT) tests showed the most sensitive response to increased LA content but the weaker LA were not scored as abnormal by most laboratories as the samples may have contained platelet fragments. Other commonly used tests such as the tissue thromboplastin inhibition (TTI) test and the dilute Russell’s viper venom test (DRVVT) were carried out somewhat inconsistently. The variability in performance of tests in different laboratories indicates that standardization of methodology is urgently required.Generally it seemed that most clotting tests were “bypassed” by the addition of phospholipid to a known LA-positive sample in apparently direct proportion to their sensitivity. Sample preparation, especially prevention of contamination with activated platelets is a vital preliminary part in the assay of LA.

1999 ◽  
Vol 81 (02) ◽  
pp. 256-258 ◽  
Author(s):  
A. Biasiolo ◽  
P. Rampazzo ◽  
T. Brocco ◽  
V. Pengo

SummaryAnti-β2-glycoprotein I (β2-GPI) antibodies behave as classical Lupus Anticoagulants (LA), as they inhibit phospholipid-dependent coagulation reactions and their activity disappears in the presence of excess exogenous phospholipids (PLs). We have recently shown that a certain amount of PLs in the dilute Russell Viper Venom Time (dRVVT) test system is required to express LA activity of anti β2-GPI antibodies. We have now extended this observation to two other tests, i.e., Kaolin Clotting Time (KCT) in which PLs are not added, and Tissue Thromboplastin Inhibition test (TTI) in which PLs are extremely diluted. In fact, affinity-purified antibody preparations from 5 patients with antiphospholipid syndrome did not express or only weakly expressed anticoagulant activity in both tests; the mean ratios of coagulation times obtained with purified antibodies and that of control buffer were 1.11 and 1.0 for KCT and TTI, respectively. On the contrary, the mean ratios in dRVVT were 1.31 and 1.49 at a PLs dilution of 1:8 and 1:64, respectively. Therefore, the presence of LA activity due to autoantibodies to β2-GPI is characterized by a positive dRVVT and negative or only weakly positive KCT and TTI.


1990 ◽  
Vol 64 (01) ◽  
pp. 026-031 ◽  
Author(s):  
J Arnout ◽  
E Huybrechts ◽  
M Vanrusselt ◽  
C Falcon ◽  
J Vermylen

SummaryClotting assays allow qualitative rather than quantitative detection of the lupus anticoagulant. We have therefore studied the usefulness of an ELISA using a commercial partial thromboplastin, Thrombofax, oS antigen; the results obtained on 146 selected patient plasmas were compared to the results of coagulation tests (kaolin clotting time, tissue thromboplastin inhibition test, activated partial thromboplastin time) and of ELISAs using cardiolipin or phosphatidylserine as antigen. While satisfactory agreement was found within the group of coagulation tests or that of ELISAs, only a moderate agreement was obtained between clotting tests and ELISAs, the best being with the partial thromboplastin ELISA using low plasma dilutions. The study further indicates that ELISA techniques cannot entirely replace coagulation tests for the detection of a lupus anticoagulant, even when a partial thromboplastin is used as antigen. On the other hand, coagulation tests are less sensitive than ELISAs for the detection of antiphospholipid antibodies.


1987 ◽  
Author(s):  
A Criel ◽  
B Gilbert ◽  
A Van Hoof ◽  
M Hidajat ◽  
A Louwagie

Lupus anticoagulant (LAC) is an antibody directed against phospholipids which prolongs in vitro clotting assays. Several detection methods have been described; however all give some different results. Recently ELISA and RIA assays have been developed which detect IgG and IgM anti-cardiolipin antibodies. The aim of our study was to compare three different LAC tests with an ELISA anti-cardiolipin test. The tests used were : kaolin clotting time (KCT or Exnertest), tissue thromboplastin inhibition test (TTI or Schleider test), activated partial thromboplastin time using a 50, 100, 200 fold dilution of the phospholipid preparation (APTT dilution test), and an IgG and IgM anti-cardiolipin ELISA test. 114 samples of patients suffering from diseases known to be accompanied with LAC antibodies (auto-immune diseases, recurrent abortion, thromboembolism, etc.) were studied. Positivity with one of the tests was found in 45 patients (39%). Patients with the diagnosis of SLE or otherimmune diseases showed the highest positivity (56%) whereas those with thromboembolism, recurrent abortion etc. were only positive in 27%.Among these 45 positive patients the TTI was positive in 41 cases (91 %);however in 10 cases (24 %) this was the only positivity found. The KCT test and the APTT dilution test were both positive in 18 cases (40 %). Anti-cardiolipin antibodies were found in 21 patients (47 %): IgG only in 12 (27 %), IgM only in 5 (11 %), both IgG and IgM in 2 (4 %); in 19 of these 21 patientsthe TTI was also positive.In our study the TTI test seems to be the most sensitive test but possibly also the test with the highest aspecific positivities. IgG and IgM anti-cardiolipin antibodies were less frequently found than expected.


2001 ◽  
Vol 101 (2) ◽  
pp. 45-51 ◽  
Author(s):  
Francesco Dragoni ◽  
Clara Minotti ◽  
Giovanna Palumbo ◽  
Franco Faillace ◽  
Roberta Redi ◽  
...  

Lupus ◽  
1998 ◽  
Vol 7 (2_suppl) ◽  
pp. 37-40 ◽  
Author(s):  
M Galli ◽  
T Barbui

Prothrombin is a common antigenic target of antiphospholipid antibodies, since anti-prothrombin antibodies are detected in about 50-90% of the patients. To allow proper immune recognition, prothrombin must be adsorbed on suitable anionic surfaces. The epitope(s) have not yet been identified: the majority of anti-prothrombin antibodies appear to be of poly- or oligoclonal nature. Anti-prothrombin antibodies, either alone or in combination with anti-β2-glycoprotein I antibodies, are responsible for the lupus anticoagulant activity of about 75% of the cases of phospholipid-dependent inhibitors of coagulation. The two antibodies may be discriminated by means of specific coagulation profiles generated by the comparison of the ratio of the Kaolin Clotting Time (KCT) and the dilute Russell's Viper Venom Time (dRVVT): the KCT profile, which mainly reflects the presence of anti-prothrombin antibodies and the dRVVT profile, which is mostly associated with anti-β2-glycoprotein I antibodies. This distinction, although somewhat artificial, may be clinically useful, since the KCT profile identifies patients at low risk to develop thrombosis. Similarly, most of the studies that measured anti-prothrombin antibodies by ELISA failed to find a significant association with thrombosis. In conclusion, the clinical relevance of these antibodies has not yet been established.


1987 ◽  
Vol 57 (02) ◽  
pp. 144-147 ◽  
Author(s):  
Esther Rosner ◽  
Rachel Pauzner ◽  
Ayala Lusky ◽  
Michaela Modan ◽  
Amira Many

SummarySixty-six SLE patients were studied for the presence of lupus type circulating anticoagulant. Forty-nine percent of them showed activity of this anticoagulant. The sensitivity of various coagulation tests was compared. Recalcification time was found to be the most sensitive screening test and the kaolin clotting time mixture test, the best for determining the presence of the anticoagulant.Tissue thromboplastin inhibition test detected only half of the patients in whom the anticoagulant was found by recalcification time and kaolin clotting time mixture test.APTT, using 2 different reagents, resulted in 73% and 52% false negatives. A numerical index for determining the presence of the anticoagulant and its quantitative evaluation is suggested.The association between thromboembolic events, recurrent abortions and the different coagulation tests is shown.


1985 ◽  
Vol 53 (01) ◽  
pp. 015-018 ◽  
Author(s):  
Thomas Exner

SummaryPotent lupus inhibitors from various patients were mixed with platelet free normal plasma and were compared in activated partial thromboplastin time (APTT), dilute prothrombin time (dil. PT), kaolin clotting time (KCT), contact product clotting time (CPCT), and Russell viper venom clotting time (RWCT) tests. In the last three tests platelets and platelet lipid substitutes were avoided to enhance the sensitivities of these tests for the lupus anticoagulant. Correlations between the KCT and the other tests were mostly good, indicating that different lupus inhibitors functioned by a similar mechanism. There was no significant trend between particular clinical symptoms and individual coagulation test combinations. The KCT was found to be the most sensitive test for the lupus inhibitor, followed by the CPCT, RWCT, dil. PT and APTT tests. Activated platelets tended to correct the APTT lupus inhibitor defect in all except the strongest inhibitor cases.


Sign in / Sign up

Export Citation Format

Share Document