Stability of Single-Bolted Thin-Walled Steel Angle Members with Stochastic Imperfections

2021 ◽  
Vol 147 (8) ◽  
Author(s):  
Zacharias Fasoulakis ◽  
Dimitrios Vamvatsikos ◽  
Vissarion Papadopoulos
Keyword(s):  
2015 ◽  
Vol 74 (4) ◽  
Author(s):  
Yeong Huei Lee ◽  
Cher Siang Tan ◽  
Shahrin Mohammad ◽  
Yee Ling Lee

Connection is an important element in structural steelwork construction. Eurocode does not provide adequate design information for mechanical properties prediction of top-seat flange cleat connection, especially for thin-walled cold-formed steel structures. Adopting hot-rolled design with neglecting thin-walled behaviour could lead to unsafe or uneconomic design. This research aims to provide accurate mechanical properties prediction for bolted top-seat flange cleat connection in cold-formed steel structures. The scope of work focuses on the effect of various thickness of the flange cleat to the rotational stiffness and strength behaviour of a beam-to-column connection. Experimentally verified and validated finite element modelling technique is applied in the parametric investigation. Two categories of flange cleat thickness, ranged from 2 mm to 40 mm are studied. From the developed numerical models, it is observed that Eurocode has overestimated the initial rotational stiffness prediction, calculated with component method. The over-estimation would influence the overall stiffness of structures and force distribution within the components. As a conclusion, a set of newly proposed accurate predictions for initial rotational stiffness and strength of cold-formed steel top-seat flange cleat connection, with the influence of the thickness of flange cleat is presented.


Author(s):  
Natalia Dmitrievna Korsun ◽  
Daria Anatolievna Prostakishina
Keyword(s):  

2018 ◽  
Vol 15 (1) ◽  
pp. 59
Author(s):  
NAZRUL AZMI AHMAD ZAMRI ◽  
CLOTILDA PETRUS ◽  
AZMI IBRAHIM ◽  
HANIZAH AB HAMID

The application of concrete filled steel tubes (CFSTs) as composite members has widely been used around the world and is becoming popular day by day for structural application especially in earthquake regions. This paper indicates that an experimental study was conducted to comprehend the behaviour of T-stub end plates connected to concrete filled thin-walled steel tube (CFTST) with different types of bolts and are subjected to pullout load. The bolts used are normal type bolt M20 grade 8.8 and Lindapter Hollo-bolt HB16 and HB20. A series of 10 mm thick T-stub end plates were fastened to 2 mm CFTST of 200 mm x 200 mm in cross-section. All of the specimens were subjected to monotonic pull-out load until failure. Based on test results, the Lidapter Hollo-bolts showed better performance compare to normal bolts. The highest ultimate limit load for T-stub end plate fasten with Lindapter Hollo-bolt is four times higher than with normal bolt although all end plates show similar behaviour and failure mode patterns. It can be concluded that T-stub end plate with Lindapter Hollo-bolt shows a better performance in the service limit and ultimate limit states according to the regulations in the design codes.


Sign in / Sign up

Export Citation Format

Share Document