Review on the use of low energy X-ray equipment in diagnostic radiology, case study: X-ray with detector system using FDR nano technology

2021 ◽  
Author(s):  
T. Kartika ◽  
I. B. G. P. Pratama
Author(s):  
Alessandra Gianoncelli ◽  
Jernej Bufon ◽  
Mahdi Ahangarianabhari ◽  
Matteo Altissimo ◽  
Pierluigi Bellutti ◽  
...  
Keyword(s):  

2018 ◽  
Vol 13 (03) ◽  
pp. C03032-C03032 ◽  
Author(s):  
J. Bufon ◽  
S. Schillani ◽  
M. Altissimo ◽  
P. Bellutti ◽  
G. Bertuccio ◽  
...  

Open Physics ◽  
2016 ◽  
Vol 14 (1) ◽  
pp. 150-158
Author(s):  
Ammar Herrati ◽  
Mourad Bourouina ◽  
Karima Khalal-Kouache

AbstractThe aim of thiswork is to study the energy dependence of thermoluminescent dosimeter (TLD-700) for low energy X-ray beams encountered in conventional diagnostic radiology. In the first step, we studied some characteristics (reproducibility and linearity) of TLD-700 chips using a 137Cs source, and selected TLD chips with reproducibility better than 2.5%. Then we determined TLD-700 energy response for diagnostic radiology X-ray qualities, and investigated its influence on air kerma estimate. A maximum deviation of 60% can be obtained if TLDs are calibrated for 137Cs radiation source and used in diagnostic radiology fields. However, this deviation became less than 20% if TLDs chips are calibrated for the reference x-ray radiation quality RQR5 (recommended by the IEC 61267 standard). Consequently, we recommend calibrating this kind of TLDdetector with RQR5 diagnostic radiology X-ray quality. This method permits to obtain a good accuracy when assessing the entrance dose in diagnostic radiology procedures.


IEEE Access ◽  
2021 ◽  
Vol 9 ◽  
pp. 49912-49919
Author(s):  
Sandun Jayarathna ◽  
Md Foiez Ahmed ◽  
Liam O'ryan ◽  
Hem Moktan ◽  
Yonggang Cui ◽  
...  

2021 ◽  
Vol 3 (2) ◽  
Author(s):  
Ibrahim Shaik ◽  
S. K. Begum ◽  
P. V. Nagamani ◽  
Narayan Kayet

AbstractThe study demonstrates a methodology for mapping various hematite ore classes based on their reflectance and absorption spectra, using Hyperion satellite imagery. Substantial validation is carried out, using the spectral feature fitting technique, with the field spectra measured over the Bailadila hill range in Chhattisgarh State in India. The results of the study showed a good correlation between the concentration of iron oxide with the depth of the near-infrared absorption feature (R2 = 0.843) and the width of the near-infrared absorption feature (R2 = 0.812) through different empirical models, with a root-mean-square error (RMSE) between < 0.317 and < 0.409. The overall accuracy of the study is 88.2% with a Kappa coefficient value of 0.81. Geochemical analysis and X-ray fluorescence (XRF) of field ore samples are performed to ensure different classes of hematite ore minerals. Results showed a high content of Fe > 60 wt% in most of the hematite ore samples, except banded hematite quartzite (BHQ) (< 47 wt%).