scholarly journals Preoperative Visualization of a Muscular Ventricular Septal Defect by 64-Slice Cardiac Computed Tomography

2008 ◽  
Vol 21 (3) ◽  
pp. 281-281 ◽  
Author(s):  
Anumeha Tandon ◽  
Robert B. Allison ◽  
Paul A. Grayburn ◽  
Baron L. Hamman ◽  
Jeffrey M. Schussler
2012 ◽  
Vol 2012 ◽  
pp. 1-4
Author(s):  
Nina P. Hofmann ◽  
Hassan Abdel-Aty ◽  
Stefan Siebert ◽  
Hugo A. Katus ◽  
Grigorios Korosoglou

Annuloaortic ectasia is a relatively rare diagnosis. Herein, we report an unusual case of an annuloaortic ectasia with asymmetric dilatation of the right coronary bulb mimicking a membranous ventricular septal defect (VSD) with Eisenmenger reaction by transthoracic echocardiography. Aortic angiography showed a dilated aortic root and moderate aortic regurgitation. Right cardiac catheterization, on the other hand, exhibited normal pulmonary artery blood pressure and normal pulmonary resistance, whereas normal venous gas values were measured throughout the caval vein and the right atrium, excluding relevant left-right shunting. Further diagnostic workup by cardiac computed tomography angiography (CCTA) unambiguously illustrated the asymmetric geometry of the ectatic aortic cusp and root causing compression of the right heart and of the right ventricular (RV) outflow tract. After review of echocardiographic acquisitions, the blood flow detected between the left and right ventricles (mimicking VSD) was interpreted as turbulent inflow from the left ventricle into the ectatic right coronary cusp. Furthermore, elevated pulmonary artery blood pressure measured by echocardiography was attributed to “functional pulmonary stenosis” due to compression of the RV outflow tract by the aorta, as demonstrated by CCTA.


1970 ◽  
Vol 25 (3) ◽  
pp. 161-163
Author(s):  
Nurun Nahar Fatema ◽  
Mamunur Rahman ◽  
Mujubul Haque

A four year old girl was diagnosed as a case of mid muscular Ventricular Septal Defect (VSD) since early infancy. She had history of failure to thrive (FTT) and recurrent chest infection or pneumonia. As her pulmonary artery pressure was almost normal she was planned for device closure on elective basis once device and technology would be available in cardiac centre of combined Military Hospital (CMH) Dhaka. Finally it was done on 21st August 2005 and patient was discharged after 72 hours observation period. Echocardiography on next morning showed complete occlusion of defect with no residual shunt. (J Bangladesh Coll Phys Surg 2007; 25 : 161-163)


1996 ◽  
Vol 78 (10) ◽  
pp. 1183-1185 ◽  
Author(s):  
Zhong-Dong Du ◽  
Nathan Roguin ◽  
Mila Barak ◽  
Sandra Glusman Bihari ◽  
Mordechai Ben-Elisha

2014 ◽  
Vol 6 (1) ◽  
pp. 59-66 ◽  
Author(s):  
Arvind Kumar Bishnoi ◽  
Pankaj Garg ◽  
Manan Desai ◽  
Pranav Sharma ◽  
Jigar Patel ◽  
...  

2020 ◽  
Vol 13 (6) ◽  
pp. e236264 ◽  
Author(s):  
Kelsey Danley ◽  
Paul Kent

A 4-month-old boy with a history of muscular ventricular septal defect and atopic dermatitis presented with decreased oral intake, loose stools, stuffy nose, mild cough and diaphoresis. The patient had an in-home exposure to COVID-19. The initial respiratory pathogen panel was positive for adenovirus, consistent with his symptoms. The following day, the COVID-19 PCR was also positive. The patient was treated with supportive care, isolation precautions were implemented and the patient was discharged on day 4. This case demonstrates the importance of testing for COVID-19 even if a patient tests positive for another virus due to the possibility of coinfection, especially in children, in order to limit spread of COVID-19 to others.


2020 ◽  
Vol 30 (10) ◽  
pp. 1517-1520
Author(s):  
Raymond N. Haddad ◽  
Régis Gaudin ◽  
Damien Bonnet ◽  
Sophie Malekzadeh-Milani

AbstractThe hybrid perventricular approach for the closure of trabecular ventricular septal defects is an attractive treatment modality for small children. Worldwide experience has shown that procedure success is influenced by the defect anatomical accessibility, operators’ expertise, and device technical features. In May 2018, a new promising device, the KONAR-Multi-functional™ ventricular septal defect occluder (Lifetech, Shenzhen, China), obtained CE-marking for septal defect transcatheter closure after the first-in-man implantation in 2013. Herein, this is the first report of successful perventricular closure of ventricular septal defect using this new device in a child with significant co-morbidities.