A clamp-on ultrasonic cross correlation flow meter for one-phase flow

1998 ◽  
Vol 9 (4) ◽  
pp. 622-630 ◽  
Author(s):  
A Worch
2013 ◽  
Vol 35 (3) ◽  
Author(s):  
Tat Thang Nguyen ◽  
Hiroshige Kikura ◽  
Ngoc Hai Duong ◽  
Hideki Murakawa ◽  
Nobuyoshi Tsuzuki

Ultrasonic Velocity Profile (UVP) method for measurement of single-phase and two-phase flow in a vertical pipe has recently been developed in the Laboratory for industrial and Environmental Fluid Dynamics, Institute of Mechanics, VAST. The signal processings of the UVP method include the ultrasonic pulse Doppler method (UDM)and the ultrasonic time-domain cross-correlation (UTDC) method. For two-phase flow, simultaneous measurements of both liquid and gas are enabled by using a multi-wave ultrasonic transducer (multi-wave TDX). The multi-wave TDX is able to emit and receive ultrasound of two different center frequencies of 2 MHz and 8 MHz at the same time and position. 2 MHz frequency with beam diameter 10 mm is exploited for measurement of gas. 8 MHz one with beam diameter 3 mm is used for liquid. Measurements have been carried out for laminar and turbulent single-phase flows and bubbly counter-current two-phase flows in two flow loops using two vertical pipes of 26 mm inner diameter (I.D.) and 50 mm I.D. respectively. Based on the measured results, assessment of each method is clarified. Applicability of each method for different conditions of pipe flow has been tested. Suggestions for application of the two methods have been recommended.


1987 ◽  
Vol 148 (2) ◽  
pp. 411-414 ◽  
Author(s):  
RI Pettigrew ◽  
W Dannels ◽  
Galloway ◽  
T Pearson ◽  
W Millikan ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Robert Hanus ◽  
Marcin Zych ◽  
Leszek Petryka ◽  
Dariusz Świsulski

Time delay estimation is an important research question having many applications in a range of technologies. Measurement of a two-phase flow in a pipeline or an open channel using radioisotopes is an example of such application. For instance, the determination of velocity of dispersed phase in that case is based on estimation of the time delay between two stochastic signals provided by scintillation probes. The proper analysis of such signals, usually in presence of noise, requires the use of advanced statistical signal processing. In this paper, the simulation studies of time delay estimation were carried out with the use of the following differential methods: average magnitude difference function, and average square difference function and proposed combined methods comprising the above-mentioned differential and cross-correlation functions are presented. Attached simulations have been carried out for models of stochastic signals corresponding to the signals obtained in gamma-ray absorption measurements of gas-liquid flow in a horizontal pipeline. The standard uncertainties of time delay estimations have been determined for each of the methods. Improved metrological properties have been stated in the combined methods in comparison with the classical cross-correlation procedure.


Sign in / Sign up

Export Citation Format

Share Document