Impact of 3-Dimensional Versus 2-Dimensional Image Distortion Correction on Stereotactic Neurosurgical Navigation Image Fusion Reliability for Images Acquired With Intraoperative Magnetic Resonance Imaging

2020 ◽  
Vol 19 (5) ◽  
pp. 599-607
Author(s):  
Alexander T Yahanda ◽  
Timothy J Goble ◽  
Peter T Sylvester ◽  
Gretchen Lessman ◽  
Stanley Goddard ◽  
...  

Abstract BACKGROUND Fusion of preoperative and intraoperative magnetic resonance imaging (iMRI) studies during stereotactic navigation may be very useful for procedures such as tumor resections but can be subject to error because of image distortion. OBJECTIVE To assess the impact of 3-dimensional (3D) vs 2-dimensional (2D) image distortion correction on the accuracy of auto-merge image fusion for stereotactic neurosurgical images acquired with iMRI using a head phantom in different surgical positions. METHODS T1-weighted intraoperative images of the head phantom were obtained using 1.5T iMRI. Images were postprocessed with 2D and 3D image distortion correction. These studies were fused to T1-weighted preoperative MRI studies performed on a 1.5T diagnostic MRI. The reliability of the auto-merge fusion of these images for 2D and 3D correction techniques was assessed both manually using the stereotactic navigation system and via image analysis software. RESULTS Eight surgical positions of the head phantom were imaged with iMRI. Greater image distortion occurred with increased distance from isocenter in all 3 axes, reducing accuracy of image fusion to preoperative images. Visually reliable image fusions were accomplished in 2/8 surgical positions using 2D distortion correction and 5/8 using 3D correction. Three-dimensional correction yielded superior image registration quality as defined by higher maximum mutual information values, with improvements ranging between 2.3% and 14.3% over 2D correction. CONCLUSION Using 3D distortion correction enhanced the reliability of surgical navigation auto-merge fusion of phantom images acquired with iMRI across a wider range of head positions and may improve the accuracy of stereotactic navigation using iMRI images.

2012 ◽  
Vol 63 (3) ◽  
pp. 170-176 ◽  
Author(s):  
Steven Co ◽  
Sonny Bhalla ◽  
Kevin Rowan ◽  
Sven Aippersbach ◽  
Simon Bicknell

Purpose The purpose of this study was to evaluate whether 3-dimensional (3D) volumetric acquisition of shoulder ultrasound (US) data for supraspinatus rotator cuff tears is as sensitive when compared with conventional 2-dimensional (2D) US and routine magnetic resonance imaging (MRI), and whether there is improved workroom time efficiency when using the 3D technique compared with the 2D technique. Methods In this prospective study, 39 shoulders underwent US and MRI examination of their rotator cuff to confirm the accuracy of both the 2D and 3D techniques. The difference in sensitivities was compared by using confidence interval analysis. The mean times required to obtain the 2D and 3D US data and to review the scans were compared by using a 1-tailed Wilcoxon test. Results Sensitivity and specificity of 2D US in detecting supraspinatus full- and partial-thickness tears was 100% and 96%, and 80% and 100%, respectively, and similar values were obtained with 3D US at 100% and 100%, and 90% and 96.6%, respectively. Analysis of the confidence limits of the sensitivities showed no significant difference. The mean time (± SD) of the overall 2D examination of the shoulder, including interpretation was 10.02 ± 3.28 minutes, whereas, for the 3D examination, it was 7.08 ± 0.35 minutes. Comparison between the 2 cohorts when using a 1-tailed Wilcoxon test showed a statistically significant difference ( P < .05). Conclusion 3D US of the shoulder is as accurate as 2D US when compared with MRI for the diagnosis of full- and partial-thickness supraspinatus rotator cuff tears, and 3D US examination significantly reduced the time between the initial scan and the radiologist interpretation, ultimately improving workplace efficiency.


Sign in / Sign up

Export Citation Format

Share Document