DETECTION OF MOTION ARTIFACT IN SPECT IMAGING WITH CINE OR SINOGRAM DISPLAYS: A CARDIAC PHANTOM STUDY
Clinical Nuclear Medicine
◽
10.1097/00003072-199310000-00027
◽
1993
◽
Vol 18
(10)
◽
pp. 918
Author(s):
R C De La Pana
◽
C K Stone
◽
J A Bianco
◽
M A Wilson
◽
S B Perlman
Keyword(s):
Motion Artifact
◽
Phantom Study
◽
Spect Imaging
◽
Cardiac Phantom
Download Full-text
Related Documents
Cited By
References
Left ventricular function assessment using 123I/99mTc dual-isotope acquisition with two semi-conductor cadmium–zinc–telluride (CZT) cameras: a gated cardiac phantom study
EJNMMI Physics
◽
10.1186/s40658-016-0163-2
◽
2016
◽
Vol 3
(1)
◽
Cited By ~ 9
Author(s):
Tanguy Blaire
◽
Alban Bailliez
◽
Fayçal Ben Bouallegue
◽
Dimitri Bellevre
◽
Denis Agostini
◽
...
Keyword(s):
Left Ventricular Function
◽
Ventricular Function
◽
Cadmium Zinc Telluride
◽
Zinc Telluride
◽
Left Ventricular
◽
Phantom Study
◽
Dual Isotope
◽
Cardiac Phantom
◽
Cadmium Zinc
◽
Function Assessment
Download Full-text
Development of a new Python-based cardiac phantom for myocardial SPECT imaging
Annals of Nuclear Medicine
◽
10.1007/s12149-020-01534-y
◽
2020
◽
Author(s):
Osama S. Hanafy
◽
Magdy M. Khalil
◽
Ibrahim M. Khater
◽
Haitham S. Mohammed
Keyword(s):
Spect Imaging
◽
Myocardial Spect
◽
Cardiac Phantom
Download Full-text
A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density, and temporal resolution: A cardiac phantom study
Medical Physics
◽
10.1118/1.3213536
◽
2009
◽
Vol 36
(11)
◽
pp. 5079-5088
◽
Cited By ~ 17
Author(s):
M. J. W. Greuter
◽
J. M. Groen
◽
L. J. Nicolai
◽
H. Dijkstra
◽
M. Oudkerk
Keyword(s):
Computed Tomography
◽
Electron Beam
◽
Temporal Resolution
◽
Phantom Study
◽
Coronary Calcium
◽
Linear Motion
◽
Electron Beam Computed Tomography
◽
Cardiac Phantom
◽
Dual Source
Download Full-text
SU-GG-I-142: A Small Field-Of-View, Mobile PET/SPECT System for Bedside Environments: A Dynamic Cardiac Phantom Study Using 99mTc and 18F-FDG
Medical Physics
◽
10.1118/1.2961540
◽
2008
◽
Vol 35
(6Part5)
◽
pp. 2674-2674
Author(s):
M Studenski
◽
D Gilland
◽
J Parker
Keyword(s):
Phantom Study
◽
Field Of View
◽
Small Field
◽
Cardiac Phantom
◽
18F Fdg
◽
Spect System
◽
Small Field Of View
Download Full-text
A cardiac phantom study on quantitative correction of coronary calcium score on multi-detector, dual source, and electron beam tomography for velocity, calcification density, and acquisition time
10.1117/12.813617
◽
2009
◽
Author(s):
Marcel J. W. Greuter
◽
Jaap M. Groen
◽
Lieuwe J. Nicolai
◽
Hildebrand Dijkstra
◽
Matthijs Oudkerk
Keyword(s):
Electron Beam
◽
Calcium Score
◽
Phantom Study
◽
Coronary Calcium
◽
Coronary Calcium Score
◽
Acquisition Time
◽
Electron Beam Tomography
◽
Cardiac Phantom
◽
Dual Source
Download Full-text
Coronary calcium mass scores measured by identical 64-slice MDCT scanners are comparable: a cardiac phantom study
The International Journal of Cardiovascular Imaging
◽
10.1007/s10554-009-9503-9
◽
2009
◽
Vol 26
(1)
◽
pp. 89-98
◽
Cited By ~ 10
Author(s):
Hildebrand Dijkstra
◽
Marcel J. W. Greuter
◽
Jaap M. Groen
◽
Rozemarijn Vliegenthart-Proença
◽
KlaasJan W. K. Renema
◽
...
Keyword(s):
Phantom Study
◽
Coronary Calcium
◽
Cardiac Phantom
Download Full-text
The effect of attenuation map, scatter energy window width, and volume of interest on the calibration factor calculation in quantitative 177Lu SPECT imaging: Simulation and phantom study
Physica Medica
◽
10.1016/j.ejmp.2018.11.009
◽
2018
◽
Vol 56
◽
pp. 74-80
◽
Cited By ~ 1
Author(s):
Elham Karimi Ghodoosi
◽
Calogero D'Alessandria
◽
Ye Li
◽
Alexandra Bartel
◽
Markus Köhner
◽
...
Keyword(s):
Phantom Study
◽
Spect Imaging
◽
Calibration Factor
◽
Energy Window
◽
Attenuation Map
◽
Window Width
◽
Volume Of Interest
◽
Imaging Simulation
Download Full-text
10.50 Comparison of different methods for cardiac volume measurement with SPECT imaging: a phantom study
Journal of Nuclear Cardiology
◽
10.1016/s1071-3581(01)80697-8
◽
2001
◽
Vol 8
(1)
◽
pp. S72-S72
Author(s):
D DAOU
◽
I POINTURIER
◽
B HELAL
◽
D VILAIN
◽
C COAGUILA
◽
...
Keyword(s):
Volume Measurement
◽
Phantom Study
◽
Spect Imaging
◽
Cardiac Volume
Download Full-text
Myocardial perfusion SPECT imaging de-noising: A phantom study
2008 IEEE International Workshop on Imaging Systems and Techniques
◽
10.1109/ist.2008.4659950
◽
2008
◽
Cited By ~ 1
Author(s):
P. Korfiatis
◽
A. Karatrantou
◽
S. Skiadopoulos
◽
N. Arikidis
◽
L. Costaridou
◽
...
Keyword(s):
Myocardial Perfusion
◽
Myocardial Perfusion Spect
◽
Phantom Study
◽
Spect Imaging
◽
Myocardial Perfusion Spect Imaging
◽
Perfusion Spect
Download Full-text
Basic stady for PVE of myocardiac SPECT image using cardiac phantom : In Tl-201, Tc-99m and I-123 SPECT imaging
Japanese Journal of Radiological Technology
◽
10.6009/jjrt.kj00001352644
◽
1995
◽
Vol 51
(8)
◽
pp. 1069
Author(s):
Yoshihiro Nishimura
◽
Masayoshi Sago
◽
Tetsurou Katabuchi
◽
Hisashi Oka
◽
Hirosi Ootakeno
◽
...
Keyword(s):
Spect Imaging
◽
Spect Image
◽
Cardiac Phantom
Download Full-text
Sign in / Sign up
Close
Export Citation Format
Close
Share Document
Close