The Key Issue of Control Strategy For Large-scale Wind Power Grid Integration

Author(s):  
Yan Li ◽  
Xinshou Tian ◽  
Jianzu Hu ◽  
Chao Liu ◽  
Cong Wang ◽  
...  
Author(s):  
Fei Xia ◽  
Zongze Xia ◽  
Peixian Cong ◽  
Zhixiong Yang ◽  
Hanbiao Song ◽  
...  

Author(s):  
Li Yunwei ◽  
Yujun Zhang ◽  
Hua Liu

Aiming at a wide range and high-frequency reactive voltage fluctuation problem in 750kV power grid which due to large-scale wind power, a coordinated control strategy of a multiple FACTS (Flexible Alternative Current Transmission Systems) configuration is investigated in the paper. System-level and electromagnetic transient level control method of multiple FACTS devices are proposed in the small wind power fluctuation, big disturbance and off-grid level, and the priorities and the principles are determined. The strategy is applied to “Xinjiang and Northwest 750kV main grid interconnection second channel project”, and the correctness and effectiveness is proved.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2287
Author(s):  
Kaina Qin ◽  
Shanshan Wang ◽  
Zhongjian Kang

With the rapid increase in the proportion of the installed wind power capacity in the total grid capacity, the state has put forward higher and higher requirements for wind power integration into the grid, among which the most difficult requirement is the zero-voltage ride through (ZVRT) capability of the wind turbine. When the voltage drops deeply, a series of transient processes, such as serious overvoltage, overcurrent, or speed rise, will occur in the motor, which will seriously endanger the safe operation of the wind turbine itself and its control system, and cause large-scale off-grid accident of wind generator. Therefore, it is of great significance to improve the uninterrupted operation ability of the wind turbine. Doubly fed induction generator (DFIG) can achieve the best wind energy tracking control in a wide range of wind speed and has the advantage of flexible power regulation. It is widely used at present, but it is sensitive to the grid voltage. In the current study, the DFIG is taken as the research object. The transient process of the DFIG during a fault is analyzed in detail. The mechanism of the rotor overcurrent and DC bus overvoltage of the DFIG during fault is studied. Additionally, the simulation model is built in DIgSILENT. The active crowbar hardware protection circuit is put into the rotor side of the wind turbine, and the extended state observer and terminal sliding mode control are added to the grid side converter control. Through the cooperative control technology, the rotor overcurrent and DC bus overvoltage can be suppressed to realize the zero-voltage ride-through of the doubly fed wind turbine, and ensure the safe and stable operation of the wind farm. Finally, the simulation results are presented to verify the theoretical analysis and the proposed control strategy.


2021 ◽  
Author(s):  
Anasuya Gangopadhyay ◽  
Ashwin K Seshadri ◽  
Ralf Toumi

<p>Smoothing of wind generation variability is important for grid integration of large-scale wind power plants. One approach to achieving smoothing is aggregating wind generation from plants that have uncorrelated or negatively correlated wind speed. It is well known that the wind speed correlation on average decays with increasing distance between plants, but the correlations may not be explained by distance alone. In India, the wind speed diurnal cycle plays a significant role in explaining the hourly correlation of wind speed between location pairs. This creates an opportunity of “diurnal smoothing”. At a given separation distance the hourly wind speeds correlation is reduced for those pairs that have a difference of +/- 12 hours in local time of wind maximum. This effect is more prominent for location pairs separated by 200 km or more and where the amplitude of the diurnal cycle is more than about  0.5 m/s. “Diurnal smoothing” also has a positive impact on the aggregate wind predictability and forecast error. “Diurnal smoothing” could also be important for other regions with diurnal wind speed cycles.</p>


2021 ◽  
Vol 54 (1) ◽  
pp. 147-154
Author(s):  
Issam Griche ◽  
Sabir Messalti ◽  
Kamel Saoudi

The uncertainty of wind power brings great challenges to large-scale wind power integration. The conventional integration of wind power is difficult to adapt the demand of power grid planning and operation. This paper proposes an instantaneous power control strategy for voltage improvement in power networks using wind turbine improving the dynamical response of power systems performances (voltage and transient stability) after fault. In which the proposed control algorithm based on a new advanced control strategy to control the injected wind power into power system. The efficiency of developed control strategy has been tested using IEEE 9 Bus. Simulation results have showed that the proposed method perform better to preserve optimal performances over wide range of disturbances for both considered scenarios studied short circuit and variable loads.


Sign in / Sign up

Export Citation Format

Share Document