Accurate modeling of induction motor loads in the load flow analysis of a distribution network

Author(s):  
Rishabh Verma ◽  
Vaskar Sarkar
2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Alma Halilović ◽  
Lejla Mujanović ◽  
Jasna Hivziefendić ◽  

The aim of this paper is to present and discuss the influence of distributed generation on power quality. Nowadays, interest in power quality has increased since it has become a very important issue in power system delivery. One of the major problems of ensuring a certain level of power quality are harmonics. The aim of this project is to investigate an impact of photovoltaic (PV) on harmonic voltage distortion (HD) in real MV distribution network. Different scenarios will be implemented where solar power plant is going to be modelled with high variability of load and generation to see their effects on the systems power quality (PQ). Those scenarios are when PV is disconnected from the grid and PVs are connected with 2 different powers. Results presented below showed that PV improves power quality of the system, because their inverters are source of harmonics and they increase HD. However, that impact is not very significant and harmonic limits are not violated. A load flow analysis is done for the model of test system 110/35/10kV in which a distributed generator is added, that is on-grid or off-grid. The network modelling and simulation is done in DIgSILENT PowerFactory software.


The Distributed generation and fast operating power electronic devices are attracting more attention due to their effective solution for improvement in the voltage profile, to meet the increasing power consumption, reduction in the power loss, enhancement in the power transfer capacity of the transmission lines, reducing the overloading of the entire network. The optimal placement of DG and FACTs devices plays key role in improvement of the network reliability and voltage stability. In this paper exhaustive load flow analysis is carried out for optimal placement of DG and UPFC. The proposed method is tested on 40 bus distribution network. The obtained results are satisfactory in terms of improvement in the overall performance of the distribution network.


Author(s):  
Muhamad Najib Kamarudin ◽  
Tengku Juhana Tengku Hashim ◽  
AbdulHamid Musa

<span>Distributed generation (DG) plays an important role in improving power quality as well as system realibility. As the incorporation of DG in the power distribution network creates several problems to the network operators, locating a suitable capacity and placement for DG will essentially help to improve the quality of power delivery to the end users. This paper presents the simulation of an application of firefly algorithm (FA) for optimally locating the most suitable placement and capacity of distributed generation (DG) in IEEE 33-bus radial distribution network. This strategy aims at minimizing losses together with improving the voltage profile in distribution network. The losses in real power and voltages at each bus are obtained using load flow analysis which was performed on an IEEE 33-bus radial distribution network using forward sweep method.  The proposed method comprises of simulation of the test system with DG as well as in the absence of DG in the system. </span><span>A comparison between the Firefly Algorithm (FA) with Genetic Algorithm (GA) is also demonstrated in this paper. The results obtained have proven that the Firefly Algorithm has a better capability at improving both the voltage profile and the power losses in the system.</span>


Sign in / Sign up

Export Citation Format

Share Document