Estimating operating mode parameters in distribution grids with regard to the peculiarities of their development

Author(s):  
Nikita D. Mukhlynin ◽  
Andrey V. Pazderin ◽  
Aleksandar Sukalo
Author(s):  
L. Gandolfi ◽  
J. Reiffel

Calculations have been performed on the contrast obtainable, using the Scanning Transmission Electron Microscope, in the observation of thick specimens. Recent research indicates a revival of an earlier interest in the observation of thin specimens with the view of comparing the attainable contrast using both types of specimens.Potential for biological applications of scanning transmission electron microscopy has led to a proliferation of the literature concerning specimen preparation methods and the controversy over “to stain or not to stain” in combination with the use of the dark field operating mode and the same choice of technique using bright field mode of operation has not yet been resolved.


2020 ◽  
pp. 28-33
Author(s):  
A. Yu. Dunaev ◽  
A. S. Baturin ◽  
V. N. Krutikov ◽  
S. P. Morozova

An improved monochromatic radiant source with spectral bandwidth of 4 nm based on supercontinuum laser and a double monochromator was included in absolute cryogenic radiometer-based facility to improve the accuracy of spectral responsivity measurement in the range 0.9–1.6 μm. The developed feedback system ensures stabilization of monochromatic radiant power with standard deviation up to 0.025 %. Radiant power that proceeds detector under test or absolute cryogenic radiometer varies from 0.1 to 1.5 mW in dependence of wavelength. The spectral power distribution of its monochromatic source for various operating mode is presented.


2018 ◽  
pp. 155-162 ◽  
Author(s):  
Sergei S. Kapitonov ◽  
Anastasia V. Kapitonova ◽  
Sergei Yu. Grigorovich ◽  
Sergei A. Medvedev ◽  
Taher Sobhy

In the article, the electrical and thermal processes in the LED lamp with varied parameters are investigated. Voltage and current measurements on all LEDs of the luminaire are carried out in the nominal operating mode. The power allocated to each LED is determined. The calculation of the LED crystal temperature was carried out using the developed thermal LED model based on the results of the measurements and by using “Multisim” program. It has been established that the temperature of the crystals of individual LEDs in the luminaire differ significantly, which leads to unfavourable thermal conditions for them and an increased likelihood of premature failure.


2018 ◽  
Vol 9 ◽  
pp. 193-201
Author(s):  
I.U. Prokopenko ◽  
◽  
S.A. Denisov ◽  
A.S. Morkovin ◽  
D.K. Nesterov ◽  
...  

2019 ◽  
Vol 85 (7) ◽  
pp. 16-21
Author(s):  
Liliya R. Mubarakova ◽  
German K. Budnikov

Sultones are cyclic esters of hydroxysulfonic acids, which are formed in the process of sulfonation of α-olefins with sulfur trioxide gas. More stable sultones may be present in the final product — an anionic surfactant — sodium α-olefin sulfonate (AOC-Na). AOC-Na is widely used in the production of household chemicals and cosmetic products, including liquid dishwashing detergents. Sultones are strong skin sensitizers, their level in AOC-Na should be strictly controlled and not exceed 5 ppm. Operational and strict control of the sultone content upon AOC-Na production allows timely adjustment at the stage of hydrolysis, which leads to a more complete disclosure of the sultone cycle with the formation of the corresponding olefin sulfonates and hydroxyalkanesulfonates. We propose a method for determining δ-hexadecansultone in liquid dishwashing detergents and sodium α-olefinsulfonates obtained on the basis of α-olefins of C14 – C16 fractions using GC/MS, which provides shortening of sample preparation and keeps the sensitivity with a detection limit of 0.02 mg/kg. The effect of various weakly polar and non-polar organic solvents used for Sultone extraction from AOC-Na and liquid detergent on liquid extraction based on the dispersion of the extractant in an alcohol/water phase is studied. When selecting the solvent we have shown that the use of diethyl ether provided the best extraction of the analyte. Determination of the analyte extraction recovery was performed using the reaction of hydrolysis of the extracted mixture. We specified the operating mode of the device which provided complete separation of the components of the analyzed compounds including the samples of liquid detergent for dishes being a multicomponent mixture of complex composition.


2020 ◽  
Vol 67 (1) ◽  
pp. 16-21
Author(s):  
Sergey M. Bakirov ◽  
Sergey S. Eliseev

The modern level of agriculture is described by the introduction of renewable energy sources. New generation sprinkler machines are being put into production, in the power system of which solar panels are used. One of the factors that negatively affect the performance of solar cells in an open field is their dusting, which is formed as a result of dust storms and wind. Cleaning of the battery panels is carried out in various ways: manual, semi-automatic and automatic. Dust cleaning is included in maintenance. (Research purpose) The research purpose is to determine the conditions for performing the maintenance, which consists in cleaning solar panels in the field. (Materials and methods) Theoretical (analysis, hypothesis design), empirical (observation, testing), experimental (ascertaining experiment) methods has been used during research. (Results and discussion) The article describes an introduced parameter for estimating the level of dusting. The power loss indicator shows the ratio of the power of the dusted module to the power of the clean module. Unscheduled maintenance is affected by the distance of the solar module from the repair point, the power of the solar module, the loss from dusting, the frequency of maintenance and cost indicators. (Conclusions) It has been found the dependence of maintenance period of the solar module of the sprinkler machine on the distance to the sprinkler machine, to the point of maintenance and repair, the power loss coefficient in case of dusting of the solar module, the cost of performing maintenance, as well as the frequency of maintenance. Article describes the boundaries of the choice of operating mode of the sprinkler between unscheduled maintenance for cleaning the solar module and the acceptance of additional power of the sprinkler power supply system according to the criterion of minimum operating costs.


2019 ◽  
Vol 290 ◽  
pp. 02007
Author(s):  
Radu Dan Paltan ◽  
Cristina Biriş ◽  
Loredana Anne-Marie Rădulescu

Of many techniques that are used to optimize production and costs, the studies conducted within a profile company lead to our choice for testing the 6Sigma method (the most used method in the automotive industry) in view of the economic efficiency applied in the wood Industry company. This method measures how many flaws exist in a process and determines in a systematic way how to improve it by technical overhauling and eliminating or minimizing the process for efficiency. This research article aims to study the state of research on the optimization of the production process through technical overhauling for panels reconstituted from solid wood and ways to make production more efficient by cutting costs through technical overhauling. From preliminary research, we estimate that all the items founded and others that will result from further research will result in a significant decrease in production costs that are reflected in the cost of the finished product and consequently in increasing the yield of the company by maximizing its profit. At the same time it may be the basis of future research studies in the field. The easier it is to maximize profits, the lower the operating costs are and the higher recovery rate of investments are, that will result a change in the operating mode: “working smarter not harder”.


Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1967
Author(s):  
Gaurav Kumar Roy ◽  
Marco Pau ◽  
Ferdinanda Ponci ◽  
Antonello Monti

Direct Current (DC) grids are considered an attractive option for integrating high shares of renewable energy sources in the electrical distribution grid. Hence, in the future, Alternating Current (AC) and DC systems could be interconnected to form hybrid AC-DC distribution grids. This paper presents a two-step state estimation formulation for the monitoring of hybrid AC-DC grids. In the first step, state estimation is executed independently for the AC and DC areas of the distribution system. The second step refines the estimation results by exchanging boundary quantities at the AC-DC converters. To this purpose, the modulation index and phase angle control of the AC-DC converters are integrated into the second step of the proposed state estimation formulation. This allows providing additional inputs to the state estimation algorithm, which eventually leads to improve the accuracy of the state estimation results. Simulations on a sample AC-DC distribution grid are performed to highlight the benefits resulting from the integration of these converter control parameters for the estimation of both the AC and DC grid quantities.


Sign in / Sign up

Export Citation Format

Share Document