Low-Cost and High-Performance Optical Fiber-Based Sensor for Liquid Level Monitoring

2019 ◽  
Vol 19 (13) ◽  
pp. 4882-4888 ◽  
Author(s):  
Joana Martins ◽  
Camilo A. R. Diaz ◽  
M. Fatima Domingues ◽  
Rute A. S. Ferreira ◽  
Paulo Antunes ◽  
...  
2014 ◽  
Vol 26 (16) ◽  
pp. 1613-1616 ◽  
Author(s):  
Xiao Lin ◽  
Yulin Li ◽  
Liyong Ren ◽  
Yiping Xu ◽  
Nana Chen ◽  
...  

2019 ◽  
Vol 19 (17) ◽  
pp. 7179-7191 ◽  
Author(s):  
Camilo A. R. Diaz ◽  
Arnaldo Leal-Junior ◽  
Carlos Marques ◽  
Anselmo Frizera ◽  
Maria J. Pontes ◽  
...  

2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
D. S. Montero ◽  
C. Vázquez

A low-cost intensity-based polymer optical fiber (POF) sensor for liquid detection applied to volumetric flasks is presented. Experimental results demonstrate the viability of the POF-based sensor system in a high-accuracy liquid level measurement scenario. Moreover, a wireless mesh sensor network based on ZigBee specification protocol to address multiplexed POF-based sensor is also developed. Experimental results demonstrate the feasibility to address a high number of optical sensors in an industrial process framework by means of this low-cost wireless solution.


2020 ◽  
Vol 16 (3) ◽  
pp. 246-253
Author(s):  
Marcin Gackowski ◽  
Marcin Koba ◽  
Stefan Kruszewski

Background: Spectrophotometry and thin layer chromatography have been commonly applied in pharmaceutical analysis for many years due to low cost, simplicity and short time of execution. Moreover, the latest modifications including automation of those methods have made them very effective and easy to perform, therefore, the new UV- and derivative spectrophotometry as well as high performance thin layer chromatography UV-densitometric (HPTLC) methods for the routine estimation of amrinone and milrinone in pharmaceutical formulation have been developed and compared in this work since European Pharmacopoeia 9.0 has yet incorporated in an analytical monograph a method for quantification of those compounds. Methods: For the first method the best conditions for quantification were achieved by measuring the lengths between two extrema (peak-to-peak amplitudes) 252 and 277 nm in UV spectra of standard solutions of amrinone and a signal at 288 nm of the first derivative spectra of standard solutions of milrinone. The linearity between D252-277 signal and concentration of amironone and 1D288 signal of milrinone in the same range of 5.0-25.0 μg ml/ml in DMSO:methanol (1:3 v/v) solutions presents the square correlation coefficient (r2) of 0,9997 and 0.9991, respectively. The second method was founded on HPTLC on silica plates, 1,4-dioxane:hexane (100:1.5) as a mobile phase and densitometric scanning at 252 nm for amrinone and at 271 nm for milrinone. Results: The assays were linear over the concentration range of 0,25-5.0 μg per spot (r2=0,9959) and 0,25-10.0 μg per spot (r2=0,9970) for amrinone and milrinone, respectively. The mean recoveries percentage were 99.81 and 100,34 for amrinone as well as 99,58 and 99.46 for milrinone, obtained with spectrophotometry and HPTLC, respectively. Conclusion: The comparison between two elaborated methods leads to the conclusion that UV and derivative spectrophotometry is more precise and gives better recovery, and that is why it should be applied for routine estimation of amrinone and milrinone in bulk drug, pharmaceutical forms and for therapeutic monitoring of the drug.


Sign in / Sign up

Export Citation Format

Share Document