Application of the weakest-link concept to the endurance limit of notched and multiaxially loaded specimens of carburized steel 16MnCrS5

2005 ◽  
Vol 28 (11) ◽  
pp. 983-995 ◽  
Author(s):  
H. BOMAS ◽  
M. SCHLEICHER
2006 ◽  
Author(s):  
Hong Lin ◽  
Robert R. Binoniemi ◽  
Gregory A. Fett ◽  
Thomas Woodard ◽  
Edward F. Punch ◽  
...  

Alloy Digest ◽  
1997 ◽  
Vol 46 (9) ◽  

Abstract Sandvik Ti-3Al-2.5V Grade 9 titanium-aluminum alloy offers excellent corrosion resistance, especially to chloride media, and has a high strength-to-weight ratio, which is especially suitable for use in aerospace applications. Tubing can be produced having a CSR (contractile strain ratio) that enhances the fatigue endurance limit. This datasheet provides information on composition, physical properties, elasticity, tensile properties, and bend strength as well as fatigue. It also includes information on corrosion resistance as well as forming, machining, and joining. Filing Code: TI-109. Producer or source: Sandvik.


Logistics ◽  
2021 ◽  
Vol 5 (1) ◽  
pp. 12
Author(s):  
Lakshmy Subramanian

Health supply chains aim to improve access to healthcare, and this can be attained only when health commodities appropriate to the health needs of the global population are developed, manufactured, and made available when and where needed. The weak links in the health supply chains are hindering the access of essential healthcare resulting in inefficient use of scarce resources and loss of lives. A chain is only as strong as its weakest link, and demand forecasting is one of the weakest links of health supply chains. Also, many of the existing bottlenecks in supply chains and health systems impede the accurate forecasting of demand, and without the ability to forecast demand with certainty, the stakeholders cannot plan and make commitments for the future. Forecasts are an important feeder for budgeting and logistics planning. Under this backdrop, the study examines how improved forecasting can lead to better short-term and long-term access to health commodities and outlines market-related risks. It explores further how incentives are misaligned creating an uneven distribution of risks, leading to the inability to match demand and supply. For this purpose, a systematic literature review was performed, analyzing 71 articles from a descriptive and content approach. Findings indicate the emerging trends in global health and the consequences of inaccurate demand forecasting for health supply chains. The content analysis identifies key factors that can pose a varying degree of risks for the health supply chain stakeholders. The study highlights how the key factors emerge as enablers and blockers, depending on the impact on the overall health supply chains. The study also provides recommendations for actions for reducing these risks. Consequently, limitations of this work are presented, and opportunities are identified for future lines of research. Finally, the conclusion confirms that by adopting a combination of approaches, stakeholders can ensure better information sharing, identify avenues of diversifying risks, and understand the implications.


Metals ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 300
Author(s):  
Wu Chen ◽  
Xiaofei He ◽  
Wenchao Yu ◽  
Maoqiu Wang ◽  
Kefu Yao

We investigated the effects of the austenitizing temperature on the microstructure, hardness, and tensile properties of case-carburized steel after vacuum carburization at 930 °C and then re-austenitization at 820–900 °C followed by oil quenching and tempering. The results show that fractures occurred early with the increase in the austenitizing temperature, although all the carburized specimens showed a similar case hardness of 800 HV0.2 and case depth of 1.2 mm. The highest fracture stress of 1919 MPa was obtained for the experimental steel when the austenitizing temperature was 840 °C due to its fine microstructure and relatively high percentage of retained austenite transformed into martensite during the tensile tests. We also found that the stress–strain behavior of case-carburized specimens could be described by the area-weighted curves of the carburized case and the core in combination. The strain hardening exponent was about 0.4 and did not vary with the increase in the austenitizing temperature. We concluded that the optimum austenitizing temperature was around 840 °C for the experimental steel.


Forests ◽  
2021 ◽  
Vol 12 (7) ◽  
pp. 827
Author(s):  
Omar Mologni ◽  
Eric D. T. Nance ◽  
C. Kevin Lyons ◽  
Luca Marchi ◽  
Stefano Grigolato ◽  
...  

Cable tensile forces in winch-assist harvesting have been investigated in order to assess the safety concerns of the technology. However, the literature is lacking, particularly in regards to the impact of winch design. In this study, a Summit Winch Assist tethering a feller-director on ground slopes up to 77% was monitored for four days. The cable tensile forces were simultaneously recorded at the harvesting and anchor machine at a frequency of 100 Hz. Cameras and GNSS devices enabled a time study of the operations and the recording of machine positions. Winch functionality and design were disclosed by the manufacturer and used for the interpretation of the results. The cable tensile forces reached 296 kN at the harvesting machine and 260 kN at the anchor machine. The slow negotiation of obstacles while moving downhill recorded the highest peaks, mainly due to threshold settings of the winch in the brake system activation. Lower but significant peaks were also recorded during stationary work tasks. The peaks, however, were limited to a few events and never exceeded the endurance limit of the cable. Overall, the study confirmed recent findings in cable tensile force analysis of active winch-assist operations and provided evidence of the underlaying mechanisms that contribute to cable tensile forces.


1990 ◽  
Vol 112 (4) ◽  
pp. 507-511 ◽  
Author(s):  
S. F. Duffy ◽  
J. M. Manderscheid

A macroscopic noninteractive reliability model for ceramic matrix composites is presented. The model is multiaxial and applicable to composites that can be characterized as orthotropic. Tensorial invariant theory is used to create an integrity basis with invariants that correspond to physical mechanisms related to fracture. This integrity basis is then used to construct a failure function per unit volume (or area) of material. It is assumed that the overall strength of the composite is governed by weakest link theory. This leads to a Weibull-type model similar in nature to the principle of independent action (PIA) model for isotropic monolithic ceramics. An experimental program to obtain model parameters is briefly discussed. In addition, qualitative features of the model are illustrated by presenting reliability surfaces for various model parameters.


Sign in / Sign up

Export Citation Format

Share Document