Microporous Coatings to Maximize Pool Boiling Heat Transfer of Saturated R-123 and Water

2015 ◽  
Vol 137 (8) ◽  
Author(s):  
Joo Han Kim ◽  
Ajay Gurung ◽  
Miguel Amaya ◽  
Sang Muk Kwark ◽  
Seung M. You

The present research is an experimental study for the enhancement of boiling heat transfer using microporous coatings. Two types of coatings are investigated: one that is bonded using epoxy and the other by soldering. Effects on pool boiling performance were investigated, of different metal particle sizes of the epoxy-based coating, on R-123 refrigerants, and on water. All boiling tests were performed with 1 cm × 1 cm test heaters in the horizontal, upward-facing orientation in saturated conditions at atmospheric pressure and under increasing heat flux. The surface enhanced by the epoxy-based microporous coatings significantly augmented both nucleate boiling heat transfer coefficients and critical heat flux (CHF) of R-123 relative to those of a plain surface. However, for water, with the same microporous coating, boiling performance did not improve as much, and thermal resistance of the epoxy component limited the maximum heat flux that could be applied. Therefore, for water, to seek improved performance, the solder-based microporous coating was applied. This thermally conductive microporous coating, TCMC, greatly enhanced the boiling performance of water relative to the plain surface, increasing the heat transfer coefficient up to ∼5.6 times, and doubling the CHF.

2017 ◽  
Vol 139 (2) ◽  
Author(s):  
Seongchul Jun ◽  
Jinsub Kim ◽  
Hwan Yeol Kim ◽  
Seung M. You

Copper HTCMC (High-temperature, Thermally Conductive Microporous Coating) with a coating thickness of ~300 µm was created by sintering 67 µm copper particles onto a flat copper surface. This was shown to be the optimum particle size and thickness combination, in terms of boiling heat transfer enhancement with water, during a prior pool boiling study conducted by Jun et al. [1]. The effects of orientation of pool boiling heat transfer in saturated distilled water at 1 atm were tested experimentally and compared with a plain copper surface. An SEM image (top left) shows the porous structure of HTCMC demonstrating reentrant cavities which promote nucleate boiling and lead to significant critical heat flux (CHF) enhancement compared to the plain copper surface (top right). The nucleate boiling incipience heat flux of HTCMC was demonstrated to be 5 kW/m2, which was an 8x reduction when compared to a plain copper surface which was found to have an incipience heat flux of 40 kW/m2. At this same 40 kW/m2 heat flux, the activated nucleation site density of HTCMC was extremely high, and each bubble appeared much smaller compared to a plain surface. This can be seen in the first row of images, captured with a high speed camera at 2,000 fps. The bubble growth times and departing bubble sizes of 0° and 90° are comparable for both HTCMC and plain surfaces with the order of 10 milliseconds and 100 micrometers. However, when oriented at 180°, the bubble growth time was the order of 100 milliseconds for both HTCMC and plain surface, and the departing bubble size was the order of 10 millimeters. This is due to the growth of a large bubble which coalesced with adjacent bubbles to become a relatively huge bubble which was stretched by buoyance forces before the bubble departed.


1999 ◽  
Author(s):  
K. N. Rainey ◽  
S. M. You

Abstract The present research is an experimental study of “double enhancement” behavior in pool boiling from heater surfaces simulating microelectronic devices immersed in saturated FC-72 at atmospheric pressure. The term “double enhancement” refers to the combination of two different enhancement techniques: a large-scale area enhancement (square pin fin array) and a small-scale surface enhancement (microporous coating). Fin lengths were varied from 0 (flat surface) to 8 mm. Effects of this double enhancement technique on critical heat flux (CHF) and nucleate boiling heat transfer in the horizontal orientation (fins are vertical) are investigated. Results showed significant increases in nucleate boiling heat transfer coefficients with the application of the microporous coating to the heater surfaces. CHF was found to be relatively insensitive to surface microstructure for the finned surfaces except in the case of the surface with 8 mm long fins. The nucleate boiling and CHF behavior has been found to be the result of multiple, counteracting mechanisms: surface area enhancement, fin efficiency, surface microstructure (active nucleation site density), vapor bubble departure resistance, and re-wetting liquid flow resistance.


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Seongchul Jun ◽  
Jinsub Kim ◽  
Seung M. You ◽  
Hwan Yeol Kim

The subcooling effect on pool boiling heat transfer using a copper microporous coating was experimentally studied in water for subcoolings of 10 K, 20 K, and 30 K at atmospheric pressure and compared to that of a plain copper surface. A high-temperature thermally conductive microporous coating (HTCMC) was made by sintering copper powder with an average particle size of 67 μm onto a 1 cm × 1 cm plain copper surface with a coating thickness of ~300 μm. The HTCMC surface showed a two times higher critical heat flux (CHF), ~2,000 kW/m2, and up to seven times higher nucleate boiling heat transfer (NBHT) coefficient, ~350 kW/m2K, when compared with a plain copper surface at saturation. The results of the subcooling effect on pool boiling showed that the NBHT of both the HTCMC and the plain copper surface did not change much with subcooling. On the other hand, the CHF increased linearly with the degree of subcooling for both the HTCMC and the plain copper surface. The increase in the CHF was measured to be ~60 kW/m2for every degree of subcooling for both the HTCMC and the plain surface, so that the difference of the CHF between the HTCMC and the plain copper surface was maintained at ~1,000 kW/m2throughout the tested subcooling range. The CHFs for the HTCMC and the plain copper surface at 30 K subcooling were 3,820 kW/m2and 2,820 kW/m2, respectively. The experimental results were compared with existing CHF correlations and appeared to match well with Zuber’s formula for the plain surface. The combined effect of subcooling and orientation of the HTCMC on pool boiling heat transfer was studied as well.


2014 ◽  
Vol 592-594 ◽  
pp. 1601-1606 ◽  
Author(s):  
Sameer Sheshrao Gajghate ◽  
Anil R. Aacharya ◽  
Anil T. Pise ◽  
Ganesh S. Jadhav

The addition of additives to the water is known to enhance boiling heat transfer. In the present investigation, boiling heat transfer coefficients are measured for Nichrome wire, immersed in saturated water with & without additive. An additive used is 2-Ethyl 1-Hexanol with varying concentrations in the range of 10-10000 ppm. Extensive experimentation of pool boiling is carried out above the critical heat flux. Boiling behavior i.e. bubble dynamics are observed at higher heat flux for nucleate boiling of water over wide ranges of concentration of additive in water. Results are encouraging and show that a small amount of surface active additive makes the nucleate boiling heat transfer coefficient considerably higher, and that there is an optimum additive (500-1000ppm) concentration for higher heat fluxes. An optimum level of enhancement is observed up to a certain amount of additive 500-1000ppm in the tested range. Thereafter significant enhancement is not observed. This enhancement may be due to change in thermo-physical properties i.e. mainly due to a reduction in surface tension of water in the presence of additive.


Author(s):  
K-J Park ◽  
D Jung ◽  
S E Shim

In this work, nucleate pool boiling heat transfer coefficients (HTCs) of five refrigerants of differing vapour pressures are measured on a horizontal, smooth copper surface of 9.53×9.53 mm. The tested refrigerants are R123, R152a, R134a, R22, and R32 and HTCs are taken from 10 kW/m2 to the critical heat flux (CHF) of each refrigerant. Wall and fluid temperatures are measured directly by thermocouples located underneath the test surface and in the liquid pool, respectively. Test results show that nucleate pool boiling HTCs of halogenated refrigerants increase as the heat flux and vapour pressure increase. This typical trend is maintained even at high heat fluxes above 200 kW/m2. Zuber's prediction equation for CHF is quite accurate showing a maximum deviation of 21 per cent for all refrigerants tested. For all refrigerants, Stephan and Abdelsalam's well-known correlation underpredicted nucleate boiling HTC data up to the CHF with an average deviation of 21.3 per cent, while Cooper's correlation overpredicted the data with an average deviation of 14.2 per cent. On the other hand, Gorenflo's and Jung et al.'s correlations showed 5.8 and 6.4 per cent deviations, respectively, in the entire nucleate boiling range up to the CHF.


Author(s):  
Joo H. Kim ◽  
Madhav R. Kashinath ◽  
Sang M. Kwark ◽  
Seung M. You

The present research is an experimental study for the enhancement of boiling heat transfer using microporous coating techniques. The effects of different metal particle sizes in the coating compound for microporous coatings on pool boiling performance of refrigerants and water are investigated. All boiling tests were performed with 1×1cm2 test heaters in the horizontal, upward-facing orientation under increasing heat flux conditions at atmospheric pressure in saturated R-123, FC-72, and water. Results showed that the enhanced surface by microporous coating technique significantly augmented both nucleate boiling heat transfer coefficient and critical heat flux of FC-72 and R-123 over a plain surface. However, the enhancement of boiling performance for water was comparatively insignificant compared to the other liquids.


1995 ◽  
Vol 117 (2) ◽  
pp. 387-393 ◽  
Author(s):  
J. P. O’Connor ◽  
S. M. You

A benign method of generating a surface microstructure that provides pool boiling heat transfer enhancement is introduced. Pool boiling heat transfer results from an enhanced, horizontally oriented, rectangular surface immersed in saturated FC-72, indicate up to an 85 percent decrease in incipient superheat, a 70 to 80 percent reduction in nucleate boiling superheats, and a ∼ 109 percent increase in the critical heat flux (CHF = 30 W/cm2), beyond that of the nonpainted reference surface. For higher heat flux conditions (19 to 30 W/cm2), localized dryout results in increased wall superheats (8 to 48°C). The enhanced surface heat transfer coefficients are four times higher than those from the reference surface and similar to those from the Union Carbide High Flux surface. Photographs that identify differences in bubble size and departure characteristics between the painted and reference surfaces are presented.


2000 ◽  
Vol 122 (3) ◽  
pp. 509-516 ◽  
Author(s):  
K. N. Rainey ◽  
S. M. You

The present research is an experimental study of “double enhancement” behavior in pool boiling from heater surfaces simulating microelectronic devices immersed in saturated FC-72 at atmospheric pressure. The term “double enhancement” refers to the combination of two different enhancement techniques: a large-scale area enhancement (square pin fin array) and a small-scale surface enhancement (microporous coating). Fin lengths were varied from 0 (flat surface) to 8 mm. Effects of this double enhancement technique on critical heat flux (CHF) and nucleate boiling heat transfer in the horizontal orientation (fins are vertical) are investigated. Results showed significant increases in nucleate boiling heat transfer coefficients with the application of the microporous coating to the heater surfaces. CHF was found to be relatively insensitive to surface microstructure for the finned surfaces except in the case of the surface with 8-mm-long fins. The nucleate boiling and CHF behavior has been found to be the result of multiple, counteracting mechanisms: surface area enhancement, fin efficiency, surface microstructure (active nucleation site density), vapor bubble departure resistance, and re-wetting liquid flow resistance. [S0022-1481(00)02603-7]


Author(s):  
Muhamad Zuhairi Sulaiman ◽  
Masahiro Takamura ◽  
Kazuki Nakahashi ◽  
Tomio Okawa

Boiling heat transfer (BHT) and critical heat flux (CHF) performance were experimentally studied for saturated pool boiling of water-based nanofluids. In present experimental works, copper heaters of 20 mm diameter with titanium-oxide (TiO2) nanocoated surface were produced in pool boiling of nanofluid. Experiments were performed in both upward and downward facing nanofluid coated heater surface. TiO2 nanoparticle was used with concentration ranging from 0.004 until 0.4 kg/m3 and boiling time of tb = 1, 3, 10, 20, 40, and 60 mins. Distilled water was used to observed BHT and CHF performance of different nanofluids boiling time and concentration configurations. Nucleate boiling heat transfer observed to deteriorate in upward facing heater, however; in contrast effect of enhancement for downward. Maximum enhancements of CHF for upward- and downward-facing heater are 2.1 and 1.9 times, respectively. Reduction of mean contact angle demonstrate enhancement on the critical heat flux for both upward-facing and downward-facing heater configuration. However, nucleate boiling heat transfer shows inconsistency in similar concentration with sequence of boiling time. For both downward- and upward-facing nanocoated heater's BHT and CHF, the optimum configuration denotes by C = 400 kg/m3 with tb = 1 min which shows the best increment of boiling curve trend with lowest wall superheat ΔT = 25 K and critical heat flux enhancement of 2.02 times.


2006 ◽  
Vol 129 (10) ◽  
pp. 1321-1332 ◽  
Author(s):  
Dong Liu ◽  
Suresh V. Garimella

Flow boiling heat transfer to water in microchannels is experimentally investigated. The dimensions of the microchannels considered are 275×636 and 406×1063μm2. The experiments are conducted at inlet water temperatures in the range of 67–95°C and mass fluxes of 221–1283kg∕m2s. The maximum heat flux investigated in the tests is 129W∕cm2 and the maximum exit quality is 0.2. Convective boiling heat transfer coefficients are measured and compared to predictions from existing correlations for larger channels. While an existing correlation was found to provide satisfactory prediction of the heat transfer coefficient in subcooled boiling in microchannels, saturated boiling was not well predicted by the correlations for macrochannels. A new superposition model is developed to correlate the heat transfer data in the saturated boiling regime in microchannel flows. In this model, specific features of flow boiling in microchannels are incorporated while deriving analytical solutions for the convection enhancement factor and nucleate boiling suppression factor. Good agreement with the experimental measurements indicates that this model is suitable for use in analyzing boiling heat transfer in microchannel flows.