Solar Thermal Driven Cooling System for a Data Center in Albuquerque New Mexico

Author(s):  
N. Fumo ◽  
V. Bortone ◽  
J. C. Zambrano

Data centers are facilities that primarily contain electronic equipment used for data processing, data storage, and communications networking. Regardless of their use and configuration, most data centers are more energy intensive than other buildings. The continuous operation of Information Technology equipment and power delivery systems generates a significant amount of heat that must be removed from the data center for the electronic equipment to operate properly. Since data centers spend up to half their energy on cooling, cooling systems becomes a key factor for energy consumption reduction strategies and alternatives in data centers. This paper presents a theoretical analysis of an absorption chiller driven by solar thermal energy as cooling plant alternative for data centers. Source primary energy consumption is used to compare the performance of different solar cooling plants with a standard cooling plant. The solar cooling plants correspond to different combinations of solar collector arrays and thermal storage tank, with a boiler as source of energy to ensure continuous operation of the absorption chiller. The standard cooling plant uses an electric chiller. Results suggest that the solar cooling plant with flat-plate solar collectors is a better option over the solar cooling plant with evacuated-tube solar collectors. However, although solar cooling plants can decrease the primary energy consumption when compared with the standard cooling plant, the net present value of the cost to install and operate the solar cooling plants are higher than the one for the standard cooling plant.

2011 ◽  
Vol 133 (4) ◽  
Author(s):  
N. Fumo ◽  
V. Bortone ◽  
J. C. Zambrano

Data centers are facilities that primarily contain electronic equipment used for data processing, data storage, and communications networking. Regardless of their use and configuration, most data centers are more energy intensive than other buildings. The continuous operation of information technology equipment and power delivery systems generates a significant amount of heat that must be removed from the data center for the electronic equipment to operate properly. Since data centers spend up to half their energy on cooling, cooling systems becomes a key factor for energy consumption reduction strategies and alternatives in the data centers. This paper presents a theoretical analysis of an absorption chiller driven by solar thermal energy as cooling plant alternative for data centers. Source primary energy consumption is used to compare the performance of different solar cooling plants with a standard cooling plant. The solar cooling plants correspond to different combinations of solar collector arrays and thermal storage tank, with a boiler as source of energy to ensure continuous operation of the absorption chiller. The standard cooling plant uses an electric chiller. Results suggest that the solar cooling plant with flat-plate solar collectors is a better option over the solar cooling plant with evacuated-tube solar collectors. However, although solar cooling plants can decrease the primary energy consumption when compared with the standard cooling plant, the net present value of the cost to install and operate the solar cooling plants are higher than the one for the standard cooling plant.


Author(s):  
Adrienne B. Little ◽  
Srinivas Garimella

Of the total electricity consumption by the United States in 2006, more than 1% was used on data centers alone; a value that continues to rise rapidly. Of the total amount of electricity a data center consumes, at least 30% is used to cool server equipment. The present study conceptualizes and analyzes a novel paradigm consisting of integrated power, cooling, and waste heat recovery and upgrade systems that considerably lowers the energy footprint of data centers. Thus, on-site power generation equipment is used to supply primary electricity needs of the data center. The microturbine-derived waste heat is recovered to run an absorption chiller that supplies the entire cooling load of the data center, essentially providing the requisite cooling without any additional expenditure of primary energy. Furthermore, the waste heat rejected by the data center itself is boosted to a higher temperature with a heat transformer, with the upgraded thermal stream serving as an additional output of the data center with no additional electrical power input. Such upgraded heat can be used for district heating applications in neighboring residential buildings, or as process heat for commercial end uses such as laundries, hospitals and restaurants. With such a system, the primary energy usage of the data center as a whole can be reduced by about 23 percent while still addressing the high-flux cooling loads, in addition to providing a new income stream through the sales of upgraded thermal energy. Given the large and fast-escalating energy consumption patterns of data centers, this novel, integrated approach to electricity and cooling supply, and waste heat recovery and upgrade will substantially reduce primary energy consumption for this important end use worldwide.


2020 ◽  
Vol 12 (17) ◽  
pp. 7042
Author(s):  
Marco Noro ◽  
Renato Lazzarin

Until recently, solar assisted heat pumps have used solar collectors as a cold source. Solar collectors provide, when possible, direct heat, otherwise they offer temperature levels to the heat pump evaporator higher than the outside air. At the same time, solar thermal cooling exploits the solar collectors and the absorption chiller only in hot months. Photovoltaic/Thermal (PVT) modules have been available on the market in recent years for solar cogeneration, but their utilization can be problematic due to PhotoVoltaic (PV) cell damage in cases where there is no heating request. This paper considers the possibility of coupling evacuated tube collectors and photovoltaic/thermal modules to drive an absorption heat pump-based plant operating as an absorption chiller in the summertime. The cold source is the solar energy and the ground, which is recharged by the solar thermal and photovoltaic/thermal collectors and by the cooling of the absorber-condenser in mid-seasons and summer. This study analyzes the system behavior in yearly operation and evaluates the role of suitable storage tanks in two different climates, varying the size of the two solar fields and the generator tank. In the best plant configuration, a primary energy ratio of 26.6 in colder climates with cloudy skies and 20 in hotter climates with clearer skies is obtained.


Energies ◽  
2019 ◽  
Vol 12 (8) ◽  
pp. 1582 ◽  
Author(s):  
Conti ◽  
Schito ◽  
Testi

This paper analyzes the use of hybrid photovoltaic/thermal (PVT) collectors in nearly zero-energy buildings (NZEBs). We present a design methodology based on the dynamic simulation of the whole energy system, which includes the building energy demand, a reversible heat pump as generator, the thermal storage, the power exchange with the grid, and both thermal and electrical energy production by solar collectors. An exhaustive search of the best equipment sizing and design is performed to minimize both the total costs and the non-renewable primary energy consumption over the system lifetime. The results show that photovoltaic/thermal technology reduces the non-renewable primary energy consumption below the nearly zero-energy threshold value, assumed as 15 kWh/(m2·yr), also reducing the total costs with respect to a non-solar solution (up to 8%). As expected, several possible optimal designs exist, with an opposite trend between energy savings and total costs. In all these optimal configurations, we figure out that photovoltaic/thermal technology favors the production of electrical energy with respect to the thermal one, which mainly occurs during the summer to meet the domestic hot water requirements and lower the temperature of the collectors. Finally, we show that, for a given solar area, photovoltaic/thermal technology leads to a higher reduction of the non-renewable primary energy and to a higher production of solar thermal energy with respect to a traditional separate production employing photovoltaic (PV) modules and solar thermal (ST) collectors.


Author(s):  
Adrienne B. Little ◽  
Srinivas Garimella

Of the total electricity consumption by the United States in 2006, more than 1% was used on data centers alone; a value that continues to rise rapidly. Of the total amount of electricity a data center consumes, about 30% is used to cool server equipment. The present study conceptualizes and analyzes a novel paradigm consisting of integrated power, cooling, and waste heat recovery and upgrade systems that considerably lower the energy footprint of data centers. Thus, on-site power generation equipment is used to supply primary electricity needs of the data center. The microturbine-derived waste heat is recovered to run an absorption chiller that supplies the entire cooling load of the data center, essentially providing the requisite cooling without any additional expenditure of primary energy. Furthermore, the remaining waste heat rejected by the data center is boosted to a higher temperature with a heat transformer, with the upgraded thermal stream serving as an additional output of the data center with negligible additional electrical power input. Such upgraded heat can be used for district heating applications in neighboring residential or commercial buildings, or as process heat for commercial end uses such as laundries, hospitals, and restaurants, depending on the location of the data center. With such a system, the primary energy usage of the data center as a whole can be reduced by up to 23% while still addressing the high-flux cooling loads, in addition to providing a new income stream through the sales of upgraded thermal energy. Given the large and fast-escalating energy consumption patterns of data centers, this novel, integrated approach to electricity and cooling supply, and waste heat recovery and upgrade will substantially reduce primary energy consumption for this important end use worldwide.


Author(s):  
Jose´ Uren˜a Lo´pez ◽  
Andreas Klesse ◽  
Hermann-J. Wagner

Cooling in residential buildings becomes more important due to the rising insulation requirements and the increasing human comfort. Therefore, systems that provide heating as well as cooling with a low primary energy consumption will be in future more preferred than conventional single-unit systems. Solar thermal installations can here provide in addition to the domestic hot water and heating demand a significant contribution to the cooling requirement in residential buildings. In this study, low-energy residential buildings with different solar heating and cooling systems are analyzed concerning their primary energy consumption. To cover a large range of different weather conditions, two locations (Madrid and Wu¨rzburg) with different solar energy supply are considered. Further, a conventional solar heating supply system including one or more typical room air-conditioners is as reference system selected. The different systems are modeled by the system simulation platform TRNSYS. In a first step, the question is addressed of whether a solar thermal system with standard dimensioning, taking the domestic hot water and heating demand into account, is sufficient to meet the cooling requirements. To cover the cooling demands, a small-scale thermally driven absorption chiller has been selected. In a next step, the studied systems are compared in terms of primary energy saving as a function of the solar cooling fraction. The simulation results have shown that regions with a high solar energy supply do not take advantage of solar thermal cooling, due to the higher cooling demand. On average, 70% of the cooling demands can be covered by a standard dimensioned solar thermal system. At the same time, a primary energy saving up to 90%, compared to currently installed room air-conditioning units can be achieved.


Author(s):  
Nelson Fumo ◽  
Louay M. Chamra ◽  
Vicente Bortone

Integrated energy systems combine distributed power generation with thermally activated components to use waste heat, improving the overall energy efficiency, and making better use of fuels. Use of solar thermal energy is attractive to improve combined cooling, heating, and power (CCHP) systems performance, particularly during summer time since the cooling load coincides very well with solar energy availability. Limitation of the use of solar systems is mainly related to high first cost and large surface area for solar energy harvesting. Therefore, solar thermal CCHP systems seem to be an alternative to increase the use of solar thermal energy as a means to increase energy systems overall efficiency and reduce greenhouse gases (GHGs) emissions. This study focuses on the use of solar collectors in CCHP systems in order to reduce PEC and emission of CO2 in office buildings. By using a base CCHP system, the energy and economic analysis are presented as the contribution of the solar system from the baseline. For comparison purposes, the analysis is made for the cities of Minneapolis (MN), Chicago (IL), New York (NY), Atlanta (GA), and Fort Worth (TX). Results show that solar thermal CCHP systems can effectively reduce the fuel energy consumption from the boiler. The potential of solar collectors in CCHP systems to reduce PEC and CO2 emission increases with the cooling demand; while the effectiveness of solar collectors to reduce primary energy consumption and CO2 emission, and the ability of the system to pay by itself from fuel savings, decreases with the number of solar collectors.


2012 ◽  
Vol 9 (2) ◽  
pp. 65
Author(s):  
Alhassan Salami Tijani ◽  
Nazri Mohammed ◽  
Werner Witt

Industrial heat pumps are heat-recovery systems that allow the temperature ofwaste-heat stream to be increased to a higher, more efficient temperature. Consequently, heat pumps can improve energy efficiency in industrial processes as well as energy savings when conventional passive-heat recovery is not possible. In this paper, possible ways of saving energy in the chemical industry are considered, the objective is to reduce the primary energy (such as coal) consumption of power plant. Particularly the thermodynamic analyses ofintegrating backpressure turbine ofa power plant with distillation units have been considered. Some practical examples such as conventional distillation unit and heat pump are used as a means of reducing primary energy consumption with tangible indications of energy savings. The heat pump distillation is operated via electrical power from the power plant. The exergy efficiency ofthe primary fuel is calculated for different operating range ofthe heat pump distillation. This is then compared with a conventional distillation unit that depends on saturated steam from a power plant as the source of energy. The results obtained show that heat pump distillation is an economic way to save energy if the temperaturedifference between the overhead and the bottom is small. Based on the result, the energy saved by the application of a heat pump distillation is improved compared to conventional distillation unit.


Energies ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2538
Author(s):  
Praveen K. Cheekatamarla

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO2 per kWh electricity.


2018 ◽  
Vol 882 ◽  
pp. 215-220
Author(s):  
Matthias Koppmann ◽  
Raphael Lechner ◽  
Tom Goßner ◽  
Markus Brautsch

Process cooling and air conditioning are becoming increasingly important in the industry. Refrigeration is still mostly accomplished with compression chillers, although alternative technologies are available on the market that can be more efficient for specific applications. Within the scope of the project “EffiCool” a technology toolbox is currently being developed, which is intended to assist industrials users in selecting energy efficient and eco-friendly cooling solutions. In order to assess different refrigeration options a consistent methodology was developed. The refrigeration technologies are assessed regarding their efficiency, CO2-emissions and primary energy consumption. For CCHP systems an exergetic allocation method was implemented. Two scenarios with A) a compression chiller and B) an absorption chiller coupled to a natural gas CHP system were calculated exemplarily, showing a greater overall efficiency for the CCHP system, although the individual COP of the chiller is considerably lower.