Economic Evaluation on GTCC Inlet Air Cooling With Absorption Chiller

Author(s):  
Cheng Yang ◽  
Zeliang Yang ◽  
Ruixian Cai

Inlet air temperature increase results in a considerable reduction in GTCC power output. Present design of inlet air cooling system usually applied static method, which considered a constant depression of inlet air temperature, an approximate estimate of runtime, output power increase and fuel consumption variation per temperature depression, etc. However, to a crumb, at least another two problems should be studied. One is GTCC performance variation with inlet air temperature, since the kilowatt increment per centigrade is not a constant; the other is off design performance of inlet air cooling system, since the inlet air temperature depression through the cooling system varies with the actual operation conditions, such as ambient air temperature and cooling water temperature, etc. This paper presents an economic evaluation with numerical integration method on GTCC inlet air cooling with absorption chiller. For a typical GTCC composed of series E gas turbine and combined components, their non-dimensional performance curves are fitted with regression equations. Associating with these equations, the inlet air temperature characteristics of GTCC are simulated; and the fitted analytical expressions for GTCC inlet air temperature characteristics are also presented. The simulation method of off design performance of a typical absorption chiller is described. For a typical GTCC with inlet air cooling in south China area, integrated with the everyday typical weather data, GTCC everyday average output power and fuel consumption, output power increment and GTCC fuel consumption increment are simulated. The simulation results show that, for every 1°C depression in inlet air temperature, the GTCC output power increases 0.5%, while heat rate varies slightly and trends towards a rise at the inlet air temperature of about 15°C. Research on inlet air cooling scheme (Scheme 10°C, cooling the ambient air temperature from ambient temperature 30°C to 10°C) shows that, Scheme 10°C yields annual average 16°C of inlet air temperature depression. Economic evaluation based on numerical integration indicates that, in the case of Scheme 10°C, annual output power increases by 8.27%, fuel consumption rate increases by 1.03%; payback period approximately amounts to 2.0 years when power price is 12 cent/(kW.h) and fuel cost is $265/t.

Author(s):  
Fadi A. Ghaith ◽  
Fadi J. Alsouda

This paper aims to evaluate the thermal performance and feasibility of integrating the Earth-Air Heat Exchanger (EAHE) with the building’s vapor compression air cooling system. In the proposed system, the ambient air is forced by an axial fan through an EAHE buried at a certain depth below the ground surface. EAHE uses the subsoil low temperature and soil thermal properties to reduce the air temperature. The outlet air from the EAHE was used for the purpose of cooling the condenser of the vapor compression cycle (VCC) to enhance its coefficient of performance (COP). The potential enhancement on the COP was investigated for two different refrigerants (i.e. R-22 and R410a) cooling systems. A mathematical model was developed to estimate the underground soil temperature at different depths and the corresponding outlet air temperature of EAHE was calculated. The obtained results showed that the soil temperature in Dubai at 4 meters depth is about 27°C and remains relatively constant across the year. In order to estimate the effect of using EAHE on the performance of the VCC system, a sample villa project was selected as a case study. The obtained results showed that EAHE system contributed efficiently to the COP of the VCC with an overall increase of 47 % and 49 % for R-22 and R410a cycles, respectively. Moreover, the calculated values were validated against Cycle_D simulation model and showed good agreement with a maximum deviation of 5%. The payback period for this project was found to be around two years while the expected life time is about 10 years which makes it an attractive investment.


2018 ◽  
Vol 70 ◽  
pp. 03011 ◽  
Author(s):  
Andrii Radchenko ◽  
Mykola Radchenko ◽  
Andrii Konovalov ◽  
Anatolii Zubarev

An advanced scavenge air cooling system for reciprocating gas engines of integrated energy system for combined electricity, heat and refrigeration generation has been developed. New method of deep scavenge air cooling and stabilizing its temperature at increased ambient air temperatures and three-circuit scavenge air cooling system with absorption lithium-bromide chiller and wet-type cooling tower was proposed. Such cooling method does not require essential constructive changes in the existing scavenge air cooling system but only an addition heat exchanger for chilling scavenge air cooling water of scavenge air low-temperature intercooler closed contour by absorption chiller. A chilled water from absorption chiller is used as a coolant. To evaluate the effect of gas engine scavenge air deeper cooling compared with its typical radiator cooling, data on the dependence of fuel consumption and power output of gas engine on ambient air temperature at the inlet of the radiator are analized. The efficiency of engine scavenge air deep cooling at increased ambient air temperatures was estimated by reducing the gas fuel consumption compared with radiator cooling.


2019 ◽  
pp. 56-60
Author(s):  
Андрій Миколайович Радченко ◽  
Ян Зонмін ◽  
Микола Іванович Радченко ◽  
Сергій Анатолійович Кантор ◽  
Богдан Сергійович Портной ◽  
...  

Significant fluctuations of the current temperature and relative humidity of the ambient air lead to significant changes in the thermal load on the cooling system at the inlet of gas turbine units (GTU), which acutely raises the problem of choosing their installed (design) thermal load. Calculations of ambient air cooling processes were carried out for different climatic conditions, for example, southern Ukraine (Mykolaiv) and Central China (Beijing). It is  analyzed two methods of determination of the installed (design) cooling capacity of the ambient air cooling system at the GTU inlet according to the maximum current reduction of fuel consumption and according to the maximum rate (increase) of annual reduction of fuel consumption following to increasing of the installed cooling capacity, calculated by summarizing the current values of fuel consumption reduction. It is shown that the values of the installed cooling capacity of the air cooling system at the GTU inlet, determined by both methods, are close enough but differ significantly for different climatic conditions. The advantage of the method of calculating the installed cooling capacity of the air cooling system at the GTU inlet according to the maximum rate of annual reduction in fuel consumption is the possibility of a more precise definition of it due to the absence of significant fluctuations in the annual reduction in fuel consumption, calculated by summarizing the current values of fuel consumption reduction. Since the maximum reduction in fuel consumption per year is achieved with some decrease in the rate of its increment at high values of the design cooling capacity, required in the hottest hours in the summer and excessive in somewhat cool periods (at night and in the morning even in the summer), the installed cooling capacity, determined according to the maximum rate of the reduction of fuel consumption, will be insufficient in times of increased thermal loads above their design value. In such cases, the elimination of the deficit in cooling capacity is possible by using an excess of cold accumulated during reduced thermal loads


1979 ◽  
Vol 101 (4) ◽  
pp. 516-523 ◽  
Author(s):  
James C. Eastwood

The efficiency of turbocharged diesel engines can be increased by cooling the charge air. This paper presents a design approach for liquid-coupled indirect-transfer heat exchanger systems to perform the air-cooling function. The two advantages most commonly cited for this approach to charge-air cooling are (1) the heat exchangers involved are easily packaged so that their shapes can be controlled by judicious design, and (2) simple gas ducting allows for compact machinery arrangements and relatively low charge-air pressure drop. An analytical approach to the design of liquid-coupled indirect-transfer heat exchanger systems is presented. Performance curves are constructed on the basis of this analysis. Four important design conditions are evident from the observation of these performance curves including (1) the relative capacity rate combination of the three fluids (ambient air, coupling liquid, and engine charge-air) which yields the highest overall effectiveness, (2) an optimum coupling-liquid flow rate, (3) the relative effectiveness distribution for each of the two component heat exchangers (hot and cold components), and (4) a broad design range for the optimum area distribution between the hot and cold exchangers. These performance curves serve as a guide for the design of a liquid-coupled charge-air cooling system.


Author(s):  
Hyun Min Kwon ◽  
Jeong Ho Kim ◽  
Tong Seop Kim

The gas turbine combined cycle is the most mature and efficient power generation system. While enhancing design performance continuously, a parallel effort to make up for the shortcomings of the gas turbine should be pursued. The most critical drawback is the large power loss in hot season when electricity demand is usually the highest. Therefore, it is important to implement an effective power boosting measure in gas turbine based power plants, especially in areas where the annual average temperature is much higher than the standard design ambient temperature. The simplest method in general is to reduce the gas turbine inlet air temperature by any means. Several schemes are commercially available, such as mechanical chilling, evaporative cooling, inlet fogging and absorption chilling. All of them have merits and demerits, either thermodynamically and economically. In this study, we focused our interest on the absorption chilling method. Theoretically, absorption chilling provides as much cooling effect (air temperature reduction) as the mechanical chilling, while electric power consumption is negligibly small. A distinct feature of an absorption chiller in contrast to a mechanical chiller is that thermal energy (heat) is needed to drive the chilling system. In this research, we propose an innovative idea of making the independent heat supply unnecessary. The new method provides simultaneous cooling of the turbine coolant and the inlet air using an absorption chiller. The inlet cooling and coolant precooling boost the gas turbine power synergistically. We predicted the system performance using cycle simulation and compared it with that of the conventional mechanical cooling system.


2018 ◽  
pp. 49-52
Author(s):  
Богдан Сергійович Портной

It is proposed the definition of the installed (rational) refrigeration capacity of a waste heat-recovery absorption-ejector chiller that utilizes the heat of the exhaust gases of a gas turbine unite to cool the air at the inlet. Since the effect of air cooling, in particular in the form of a reduction in the specific fuel consumption, depends on its depth (the magnitude of the decrease in air temperature) and duration, it is proposed to determine it by the annual fuel economy. As an example of air cooling at the inlet of a gas turbine unit, the value of reducing specific fuel consumption due to cooling the air at the inlet to the temperature of 15 °C by an absorption lithium-bromide chiller and two-stage air cooling: to a temperature of 15 °C in an absorption lithium-bromide chiller and down to 10 °C – in a refrigerant ejector chiller as the stages of a two-stage absorption-ejector chiller, depending on the installed (design) refrigeration capacity is analyzed.It is shown that proceeding from the different rate of increment of the annual reduction in the specific fuel consumption due to the change in the thermal load in accordance with the current climatic conditions, it is necessary to choose such design heat load for the air cooling system (installed refrigeration capacity of the chillers), which ensures the achievement of the maximum or close to annual reduction in the specific fuel consumption at relatively high rates of its increment. In order to determine the installed refrigeration capacity, which ensures the maximum annual refrigeration capacity (annual production of cold), the dependence of the increment of annual fuel economy from the installed refrigeration capacity is analyzed. Based on the results of the investigation, it was proposed to determine the rational thermal load of the air cooling system (installed - the design refrigeration capacity of the chiller) in accordance with the changing climatic conditions of operation during the year, which provides a maximum annual reduction in the specific fuel consumption at relatively high rates of its increment


Energies ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 6201
Author(s):  
Andrii Radchenko ◽  
Eugeniy Trushliakov ◽  
Krzysztof Kosowski ◽  
Dariusz Mikielewicz ◽  
Mykola Radchenko

The efficiency of cooling ambient air at the inlet of gas turbines in temperate climatic conditions was analyzed and reserves for its enhancing through deep cooling were revealed. A method of logical analysis of the actual operation efficiency of turbine intake air cooling systems in real varying environment, supplemented by the simplest numerical simulation was used to synthesize new solutions. As a result, a novel trend in engine intake air cooling to 7 or 10 °C in temperate climatic conditions by two-stage cooling in chillers of combined type, providing an annual fuel saving of practically 50%, surpasses its value gained due to traditional air cooling to about 15 °C in absorption lithium-bromide chiller of a simple cycle, and is proposed. On analyzing the actual efficiency of turbine intake air cooling system, the current changes in thermal loads on the system in response to varying ambient air parameters were taken into account and annual fuel reduction was considered to be a primary criterion, as an example. The improved methodology of the engine intake air cooling system designing based on the annual effect due to cooling was developed. It involves determining the optimal value of cooling capacity, providing the minimum system sizes at maximum rate of annual effect increment, and its rational value, providing a close to maximum annual effect without system oversizing at the second maximum rate of annual effect increment within the range beyond the first maximum rate. The rational value of design cooling capacity provides practically the maximum annual fuel saving but with the sizes of cooling systems reduced by 15 to 20% due to the correspondingly reduced design cooling capacity of the systems as compared with their values defined by traditional designing focused to cover current peaked short-term thermal loads. The optimal value of cooling capacity providing the minimum sizes of cooling system is very reasonable for applying the energy saving technologies, for instance, based on the thermal storage with accumulating excessive (not consumed) cooling capacities at lowered current thermal loads to cover the peak loads. The application of developed methodology enables revealing the thermal potential for enhancing the efficiency of any combustion engine (gas turbines and engines, internal combustion engines, etc.).


2012 ◽  
Vol 52 (No. 2) ◽  
pp. 39-47
Author(s):  
V. Šleger ◽  
P. Neuberger

This paper first proposes a technique of computing air temperature and humidity in stables based on outdoor air parameters and biological production of animals. The computation technique is outlined. The calculated values are then used to assess the potential of evaporation cooling in mild climatic conditions. Graphs illustrate the assumed effect of evaporation cooling equipment inside a stable housing of egg laying hens. Used in the computation were hourly meteorological readings obtained during the period May to August in years 2000 to 2002, in the locality with a potential installation of a cooling system. Other Graphs illustrate the time the animals spent in an environment with a particular air temperature. For instance in June 2002, the time animals in the stable were exposed to temperatures 27°C or higher was reduced by using an air cooling system from 39 h to 22 h, and in July 2002 from 33 h to 4 h. The envisaged model can be modified for other kinds of gallinaceous poultry and pigs.


Author(s):  
Farshid Zabihian ◽  
Alan S. Fung ◽  
Fabio Schuler

Gas turbine-based power plants are very sensitive to ambient conditions and their output power and efficiency can be decreased significantly with increase in the ambient temperature. Various compressor inlet air cooling systems have been proposed and utilized to reduce inlet air temperature to the system, including evaporative systems e.g. media and fogging, and mechanical cooling systems. In this work, different techniques for compressor inlet air cooling are briefly reviewed. Then, the fogging system employed in the Whitby cogeneration power plant is explained with particular attention to the location of the system installation. A model of the gas turbine-based cogeneration plant is also developed to simulate the Whitby cogeneration power plant. The effects of fogging compressor inlet air cooling system on the performance of the plant are investigated. The results indicate that at an ambient temperature of 30°C and relative humidity of 40% the inlet cooling of as high as 8.4°C is possible which can increase output power to more than 50 MW. Also, it is found that the model can predict the gas turbine exhaust temperature and the plant’s power production with the error level of lower than 0.5% and 3%, respectively.


Irriga ◽  
2010 ◽  
Vol 15 (2) ◽  
pp. 140-150
Author(s):  
Antonio José Steidle Neto ◽  
SÉRGIO ZOLNIER

Este trabalho foi conduzido com o objetivo de analisar o desempenho de um sistema de resfriamento evaporativo do ar (tipo painel-exaustor) em casa-de-vegetação, ao longo do período diurno em dias com condições climáticas distintas. Foram realizadas medições de temperatura e umidade relativa do ar no interior e exterior de uma casa-de-vegetação durante o período de crescimento e desenvolvimento de tomateiros cultivados em substrato de areia. Verificou-se que as eficiências médias diárias de resfriamento evaporativo do ar variaram entre 74% e 81%. Os decréscimos máximos na temperatura do ar, imediatamente após a sua passagem pelo painel de celulose, foram de 8,2ºC e 11,4ºC. Observou-se ainda que, a eficiência de resfriamento do ar foi sensivelmente melhorada quando o déficit de pressão de vapor d'água do ar externo foi superior a 1,8 kPa.   UNITERMOS: déficit de pressão de vapor d'água do ar, temperatura do ar, eficiência de resfriamento evaporativo.     STEIDLE NETO, A. J.; ZOLNIER, S. EVAPORATIVE AIR COOLING SYSTEM PERFORMANCE IN A GREENHOUSE     2 ABSTRACT   This work aimed to analyze the performance of an evaporative air cooling system (pad-fan type) in greenhouse along daytime period in days with different climatic conditions. Air temperature and relative humidity measurements inside and outside of an greenhouse were made during the growing period of tomato plants cultivated in sand substrate. It was verified that the average daily evaporative cooling efficiency ranged from 74% to 81%. The maximum air temperature decrements, immediately after its passage through the cellulose pad, were 8.2°C and 11.4°C. It was also observed that the air cooling efficiency was sensitively improved when the vapor pressure deficit of the external air was higher than 1.8 kPa.   KEYWORDS: vapor pressure deficit, air temperature, evaporative cooling efficiency.  