scholarly journals Diagnostic accuracy of screening tests for COPD: a systematic review and meta-analysis

BMJ Open ◽  
2015 ◽  
Vol 5 (10) ◽  
pp. e008133 ◽  
Author(s):  
Shamil Haroon ◽  
Rachel Jordan ◽  
Yemisi Takwoingi ◽  
Peymane Adab
PLoS ONE ◽  
2020 ◽  
Vol 15 (11) ◽  
pp. e0242415
Author(s):  
Gunjeet Kaur ◽  
P. V. M. Lakshmi ◽  
Ashu Rastogi ◽  
Anil Bhansali ◽  
Sanjay Jain ◽  
...  

Aim This systematic review aimed to ascertain the diagnostic accuracy (sensitivity and specificity) of screening tests for early detection of type 2 diabetes and prediabetes in previously undiagnosed adults. Methods This systematic review included published studies that included one or more index tests (random and fasting tests, HbA1c) for glucose detection, with 75-gram Oral Glucose Tolerance Test (or 2-hour post load glucose) as a reference standard (PROSPERO ID CRD42018102477). Seven databases were searched electronically (from their inception up to March 9, 2020) accompanied with bibliographic and website searches. Records were manually screened and full text were selected based on inclusion and exclusion criteria. Subsequently, data extraction was done using standardized form and quality assessment of studies using QUADAS-2 tool. Meta-analysis was done using bivariate model using Stata 14.0. Optimal cut offs in terms of sensitivity and specificity for the tests were analysed using R software. Results Of 7,151 records assessed by title and abstract, a total of 37 peer reviewed articles were included in this systematic review. The pooled sensitivity, specificity, positive (LR+) and negative likelihood ratio (LR-) for diagnosing diabetes with HbA1c (6.5%; venous sample; n = 17 studies) were 50% (95% CI: 42–59%), 97.3% (95% CI: 95.3–98.4), 18.32 (95% CI: 11.06–30.53) and 0.51 (95% CI: 0.43–0.60), respectively. However, the optimal cut-off for diagnosing diabetes in previously undiagnosed adults with HbA1c was estimated as 6.03% with pooled sensitivity of 73.9% (95% CI: 68–79.1%) and specificity of 87.2% (95% CI: 82–91%). The optimal cut-off for Fasting Plasma Glucose (FPG) was estimated as 104 milligram/dL (mg/dL) with a sensitivity of 82.3% (95% CI: 74.6–88.1%) and specificity of 89.4% (95% CI: 85.2–92.5%). Conclusion Our findings suggest that at present recommended threshold of 6.5%, HbA1c is more specific and less sensitive in diagnosing the newly detected diabetes in undiagnosed population from community settings. Lowering of thresholds for HbA1c and FPG to 6.03% and 104 mg/dL for early detection in previously undiagnosed persons for screening purposes may be considered.


BMJ Open ◽  
2020 ◽  
Vol 10 (10) ◽  
pp. e038449
Author(s):  
Lisa Helen Telford ◽  
Leila Hussein Abdullahi ◽  
Eleanor Atieno Ochodo ◽  
Liesl Joanna Zuhlke ◽  
Mark Emmanuel Engel

ObjectiveTo summarise the accuracy of handheld echocardiography (HAND) which, if shown to be sufficiently similar to that of standard echocardiography (STAND), could usher in a new age of rheumatic heart disease (RHD) screening in endemic areas.DesignSystematic review and meta-analysis.Data sourcesPubMed, Scopus, EBSCOHost and ISI Web of Science were initially searched on 27 September 2017 and again on 3 March 2020 for studies published from 2012 onwards.Eligibility criteriaStudies assessing the accuracy of HAND compared with STAND when performed by an experienced cardiologist in conjunction with the 2012 World Heart Federation criteria among populations of children and adolescents living in endemic areas were included.Data extraction and synthesisTwo reviewers independently extracted data and assessed the methodological quality of included studies against review-specific Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 criteria. A meta-analysis using the hierarchical summary receiver operating characteristic model was conducted to produce summary results of sensitivity and specificity. Forest plots and scatter plots in receiver operating characteristic space in combination with subgroup analyses were used to investigate heterogeneity. Publication bias was not investigated.ResultsSix studies (N=4208) were included in the analysis. For any RHD detection, the pooled results from six studies were as follows: sensitivity: 81.56% (95% CI 76.52% to 86.61%) and specificity: 89.75% (84.48% to 95.01%). Meta-analytical results from five of the six included studies were as follows: sensitivity: 91.06% (80.46% to 100%) and specificity: 91.96% (85.57% to 98.36%) for the detection of definite RHD only and sensitivity: 62.01% (31.80% to 92.22%) and specificity: 82.33% (65.15% to 99.52%) for the detection of borderline RHD only.ConclusionsHAND displayed good accuracy for detecting definite RHD only and modest accuracy for detecting any RHD but demonstrated poor accuracy for the detection of borderline RHD alone. Findings from this review provide some evidence for the potential of HAND to increase access to echocardiographic screening for RHD in resource-limited and remote settings; however, further research into feasibility and cost-effectiveness of wide-scale screening is still needed.PROSPERO registration numberCRD42016051261.


Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S264-S265
Author(s):  
Yehia Fanous ◽  
Pavel Antiperovitch ◽  
Jacob Fanous ◽  
Anthony S. Tang

2021 ◽  
pp. 101464
Author(s):  
Serena Incerti Parenti ◽  
Andrea Fiordelli ◽  
Maria Lavinia Bartolucci ◽  
Stefano Martina ◽  
Vincenzo D’Antò ◽  
...  