scholarly journals Early respiratory diagnosis: benefits of enhanced lung function assessment

2021 ◽  
Vol 8 (1) ◽  
pp. e001012
Author(s):  
Karl P Sylvester ◽  
Luke Youngs ◽  
M A Rutter ◽  
Ross Beech ◽  
Ravi Mahadeva

IntroductionThe National Health Service for England Long Term Plan identifies respiratory disease as one of its priority workstreams. To assist with earlier and more accurate diagnosis of lung disease they recommend improvement in delivery of quality-assured spirometry. However, there is a likelihood that patients will present with abnormal gas exchange when spirometry results are normal and therefore there will be a proportion of patients whose time to diagnosis is still protracted. We wished to determine the incidence rate of this occurring within our Trust.MethodsA retrospective review of all patients attending the lung function laboratory for their first pulmonary function assessment from June 2006 to December 2020 was undertaken. Forced expiratory volume in 1 s/forced vital capacity (FEV1/FVC) >−1.64 standardised residual (SR) was used to confirm no obstructive lung function abnormality and FVC >−1.64 SR to confirm no suggestion of a restrictive lung function abnormality. Lung gas transfer for carbon monoxide (TLCO) and transfer coefficient of the lung for carbon monoxide (KCO) <−1.64 SR confirmed the presence of a gas exchange abnormality. Spirometry and gas transfer reference values generated by the Global Lung Initiative were used to determine normality.ResultsOf 12 835 eligible first visits with normal FEV1/FVC and FVC, 4856 (37.8%) were identified as having an abnormally low TLCO and 3302 (25.7%) presenting with an abnormally low KCO. Of 3494 with FEV1/FVC SR <−1.64, 3316 also had a ratio of <0.70, meaning 178 (5%) of patients in this cohort would have been misclassified as having obstructive lung disease using the 0.70 cut-off recommended by the Global Initiative for Chronic Obstructive Lung Disease for diagnosing obstructive lung disease.DiscussionIn conclusion, to assist with ensuring more accurate and timely diagnosis of lung disease and enhance patients’ diagnostic pathway, we recommend the performance of lung gas transfer measurements alongside spirometry in all healthcare settings. To assess and monitor gas transfer at the earliest opportunity we recommend this is implemented into new models being developed within community hubs. This will increase the identification of lung function abnormalities and provide patients with a definitive diagnosis earlier.

BMJ Open ◽  
2020 ◽  
Vol 10 (6) ◽  
pp. e036045
Author(s):  
Diana Crossley ◽  
James Stockley ◽  
Charlotte E Bolton ◽  
Nicholas S Hopkinson ◽  
Ravi Mahadeva ◽  
...  

ObjectivesTo establish a database network for the study of alpha-1 antitrypsin deficiency (AATD) and compare the results to CT lung density as the most direct measure of emphysema.DesignA central electronic database was established to permit the upload of anonymised patient data from remote sites. Prospectively collected CT data were recorded onto disc, anonymised, analysed at the coordinating centre and compared with the clinical features of the disease.SettingTertiary referral centres with expertise in the management of AATD focused on academic Biomedical Research Units and Wellcome Clinical Research Facilities.ParticipantsData were collected from 187 patients over 1 year from eight UK academic sites. This included patient demographics, postbronchodilator physiology, health status and CT. Analysis was undertaken at the coordinating centre in Birmingham.ResultsPatient recruitment in the 12 months reached 94% of target (set at 200) covering the whole spectrum of the disease from those with normal lung function to very severe chronic obstructive lung disease. CT scan suitable for analysis was available from 147 (79%) of the patients. CT density, analysed as the threshold for the lowest 15% of lung voxels, showed statistically significant relationships with the objective physiological parameters of lung function as determined by spirometric Global Initiative for Chronic Obstructive Lung Disease (GOLD) severity staging (p<0.001) and carbon monoxide gas transfer (p<0.01). Density also correlated with subjective measures of quality of life (p=0.02).ConclusionsEstablishment of the network for data collection and its transfer was highly successful facilitating future collaboration for the study of this rare disease and its management. CT densitometry correlated well with the objective clinical features of the disease supporting its role as the specific marker of the associated emphysema and its severity. Correlations with subjective measures of health, however, were generally weak indicating other factors play a role.


1981 ◽  
Vol 1 (5) ◽  
pp. 461-466 ◽  
Author(s):  
Mary Therse Hynak ◽  
Mohamed S. Al-Ibrahim ◽  
Robert M. Russell ◽  
Gina Stanko ◽  
C.V.J. Verghease ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document