Interpreting Impedance Spectra in Time-Constant Domain: Application to the Passive Film on Titanium

Metals ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 928
Author(s):  
Pedro P. Socorro-Perdomo ◽  
Néstor R. Florido-Suárez ◽  
Ionelia Voiculescu ◽  
Julia C. Mirza-Rosca

Depending on the properties required for the medical instruments, compared with the classical materials, the high-entropy alloys (HEAs) are a versatile option. Electrochemical Impedance Spectroscopy (EIS) measurements have been performed on AlxCoCrFeNi-type high-entropy alloys with various concentrations of Al content (x = 0.6, 0.8, and 1.0) in order to characterize their passive film and corrosion resistance at 37 °C under infectious simulated physiological conditions (Ringer´s solution acidulated with HCl) at pH = 3. The impedance spectra were obtained at different potential values between −0.7 and +0.7 V vs. SCE. Analysis of the impedance spectra was carried out by fitting different equivalent circuits to the experimental data. Two equivalent circuits, with one time constant and two time constants respectively, can be satisfactorily used for fitting the spectra: one time constant represents the characteristics of the compact passive film, and the second one is for the porous passive film. With the decreasing of Al content, the obtained EIS results are correlated with the evolution of the microhardness and microstructure, which is characterized by Optical Microscopy (OM), Scanning Electron Microscopy (SEM), and Energy-Dispersive X-Ray Spectroscopy (EDAX). It can be observed for all alloys that the resistance of the passive film is very high and decreases with the potential: the very high resistance of the passive film implies a high corrosion resistance, which can be assigned to the formation of the protective oxide layer and demonstrates that the analyzed alloys fulfill the prerequisites for their use as new materials for the manufacturing of medical instruments.


2020 ◽  
pp. 1-1
Author(s):  
Roberto G. Ramirez-Chavarria ◽  
Celia Sanchez-Perez ◽  
Luisa Romero-Ornelas ◽  
Eva Ramon-Gallegos

2021 ◽  
Vol 187 ◽  
pp. 109501
Author(s):  
Linqian Wang ◽  
Darya Snihirova ◽  
Min Deng ◽  
Cheng Wang ◽  
Bahram Vaghefinazari ◽  
...  

1968 ◽  
Vol 11 (4) ◽  
pp. 842-852 ◽  
Author(s):  
H. N. Wright

Previous findings on the threshold for tones as a function of their duration have suggested that such functions may be systematically affected by sensori-neural hearing losses of cochlear origin. The present series of investigations was designed to explore this relation further and to determine also whether the amount of hearing loss present has any effect upon the results which are obtained. Preliminary studies were also carried out on a conductively impaired listener to indicate whether hearing losses of this type affect the threshold-duration function. The results indicate that the threshold-duration function is systematically affected by sensori-neural hearing losses of cochlear origin. This effect is manifested by a progressive shortening of the time constant relating threshold to duration and is not uniquely related to the amount of hearing loss present. The results obtained from the conductively impaired listener suggested that this type of hearing loss has no effect on the threshold-duration function, thereby implying that such functions may contribute significantly to the differential diagnosis of auditory disorders.


1993 ◽  
Vol 28 (11-12) ◽  
pp. 257-261
Author(s):  
M. Truett Garrett ◽  
Zaki Ahmad ◽  
Shelly Young

The recent requirements by U.S.E.P.A. for dechlorination and biomonitoring have increased the importance of automatic control of effluent chlorination in wastewater treatment plants. Difficulties with the Ziegler-Nichols controller tuning procedure were reported at the Kyoto Workshop, 1990. Problems are caused by the noise of incomplete mixing, a long time constant, and the disturbances of changing flow and chlorine demand. The Astrom-Hagglund relay feedback procedure provides acceptable control while data is logged to determine the controller constants. Experiences in using the procedure in existing facilities (not redesigning the mixing point) and the quality of control are presented.


Sign in / Sign up

Export Citation Format

Share Document