scholarly journals Foreign Body Moves Retrograde through Ileocecal Valve during Colonoscopy

2017 ◽  
Vol 2017 ◽  
pp. 1-4
Author(s):  
Maria Paparoupa ◽  
Markus Bruns-Toepler

Ingestion of foreign bodies and particularly of button or/and cylindrical batteries is frequent in children and adults with underlying psychiatric diseases. We present a case of a 30-year-old woman with unstable borderline disorder, where overall 4 button and 2 cylindrical batteries were endoscopically removed from her digestive system. During the last session of colonoscopy a peculiar incident was observed, as a cylindrical battery of 15 mm diameter and 43 mm length moved retrograde through ileocecal valve into the small bowel. The foreign body removal from terminal ileum was effective and safe using an endoscopic loop. This report suggests that endoscopic insertion in terminal ileum should be attempted in every colonoscopy session conducted under the indication of foreign body removal, as the possibility of retrograde movement of even large foreign bodies in the colon and through ileocecal valve is given.

Author(s):  
P D Chakravarty ◽  
T Kunanandam ◽  
G Walker

Abstract Background Ingested foreign bodies are a common presentation to paediatric ENT services. Depending on the site, these are usually managed with flexible or rigid oesophagoscopy and retrieval. This paper presents a novel technique for removing a hollow foreign body that could not be removed using conventional means. Method and results After rigid and flexible approaches failed, a guidewire was passed through the foreign body under fluoroscopic guidance and a dilatation balloon passed through the lumen of the object. Inflating the balloon allowed dilatation of the inflamed mucosa above and below the object, facilitating straightforward removal under traction. Conclusion This is a novel and reproducible technique that uses equipment readily available in tertiary referral centres. Employed in this context, the technique enabled removal of an impacted object surrounded by granulation tissue, and would be appropriate for other objects with a lumen.


2014 ◽  
Vol 129 (1) ◽  
pp. 93-94 ◽  
Author(s):  
W Nivatvongs ◽  
M Ghabour ◽  
G Dhanasekar

AbstractBackground:Removing a button battery from the ear can be a tricky and challenging procedure.Method and Results:We describe the innovative use of a magnetic telescopic rod to successfully remove a button battery from the ear canal of a nine-year-old boy.Conclusion:We propose that this equipment should be available in ENT clinics and operating theatres to be used for removing foreign bodies made from ferrous materials.


2014 ◽  
Vol 24 (02) ◽  
pp. 196-200
Author(s):  
Morteza Tahmasebi ◽  
Hamdollah Zareizadeh ◽  
Azim Motamedfar

Abstract Background and Objective: Detection of radiolucent soft-tissue foreign bodies is a challenging problem, which is especially further complicated when retained foreign body is highly suggested by clinicians but radiography is negative. So, blind exploration is sometimes hazardous for patients. The purpose of this study was to determine the accuracy of ultrasonography (USG) in detecting radiolucent soft-tissue foreign bodies in the extremities. Materials and Methods: From November 2011 to January 2012, patients with clinically suspected radiolucent soft-tissue foreign body and negative radiography were evaluated by USG with a 12-MHz linear array transducer. The patients with positive clinical and USG examination were included in our study and underwent exploration or USG removal. Results: Fifty-one patients underwent foreign body removal under ultrasonography-guided or surgical exploration and 47 patients had foreign body (31, 12, 3, and 1 case had thorn, wood, glass, and plastic, respectively). Ultrasound was positive in 50 patients. USG falsely predicted the presence of foreign body in four cases and was falsely negative in one of the cases. Accuracy, sensitivity, and positive predictive value were determined as 90.2%, 97.9%, and 92%, respectively. Conclusions: The real-time high-frequency USG is a highly sensitive and accurate tool for detecting and removing radiolucent foreign bodies which are difficult to be visualized by routine radiography.


2020 ◽  
Vol 2020 ◽  
pp. 1-4
Author(s):  
Jian Cao ◽  
Baihua Chen ◽  
Yun Li

Purpose. To report a novel technique of cross-knotted suture basket and to test its effectiveness in large nonmagnetic intraocular foreign body (IOFB) removal. Methods. A 7/0 Vicryl suture was cut in half and cross-knotted, and four ends were introduced into a 23G needle to form a basket. Pig eyes were used to set up the IOFB model, and the effectiveness of the suture basket in the removal of large nonmagnetic intraocular foreign bodies was tested. Results. Several modifications can be made to adapt to different situations. For the materials (stone, metal, glass, and wood) and shapes (irregular, spherical, and rectangle) of large IOFB tested, the cross-knotted suture basket successfully removed all kinds of IOFBs. Conclusion. The suture basket technique provides an accessible, safe, and effective alternative in large nonmagnetic IOFB removal. It can be adapted and interchangedand also worth’s further clinical investigations.


2018 ◽  
Vol 100 (8) ◽  
pp. 632-634 ◽  
Author(s):  
S Morris ◽  
MS Osborne ◽  
AL McDermott

Introduction Foreign body removal is a common reason for children to attend the emergency department. Generally, aural and nasal foreign bodies are not associated with immediate morbidity unless they are button batteries. There can be consequences of migration and removal. Methods Hospital Episode Statistics for 2010–2016 were used to calculate the number of nasal and aural foreign bodies that have been removed in hospital. Data for adults and children have been compared. Results 8752 nasal and 17,325 aural foreign bodies have been removed from adults and children over the course of 6 years. Children were responsible for 95% of the 8353 nasal and 85% of the 14,875 aural foreign body presentations. Children aged 1–4 years are most at risk of injury. Conclusion Children are more likely to present to hospital than adults with a foreign body in the ear or nose. Aural bodies were more likely to need removal in hospital for both populations. Authors believe that these require identification and removal by an ear, nose and throat specialist to prevent morbidity. The overall number of procedures performed annually in children has not reduced over the study period; an average of 1218 nasal and 2479 aural foreign body removals are performed each year with an annual cost of £2,880,148 to NHS England.


Author(s):  
Darren Jonathan Leitao ◽  
Jodi L. P. Jones

Abstract We present the case of an eight year old boy who presented with foreign body aspiration during the COVID-19 pandemic. The patient was taken the operating room for rigid bronchoscopy and foreign body removal. The details of the operation, steps taken for protection of health care workers, and lessons learned are discussed. Bronchoscopy was performed using N95 respirators and Stryker Flyte Hood garments, combined with a streamlined instrument set-up. Simulation in advance of these cases improves communication and operative planning. Surgeons should have equipment to retrieve foreign bodies from the oropharynx available. Techniques that reduce surgical time and thus exposure risk should be considered.


2019 ◽  
Vol 7 (2) ◽  
pp. 82-84
Author(s):  
Rajesh Poudel ◽  
Samir Shrestha

 The pica phenomenon is common in patients with behavioral and developmental disorders, particularly autism. Most ingested foreign bodies pass through the gastrointestinal system spontaneously and without complication. Small bowel obstruction is an uncommon complication of ingested foreign body. Herein, we present the case of an autistic child who was operated for peritonitis due to an unusual foreign body.


2020 ◽  
Vol 11 (02) ◽  
pp. 170-172
Author(s):  
Sridhar Sundaram ◽  
Suprabhat Giri ◽  
Biswaranjan Patra ◽  
Harish Darak ◽  
Shobna Bhatia

Abstract Background The majority of foreign bodies entering the small intestine are passed spontaneously. However, in case of a sharp object, its removal is an urgency due to a higher risk of intestinal perforation, and endoscopic intervention is an appropriate management strategy as surgery is associated with greater morbidity. Although enteroscopy is the standard practice for the removal of a foreign body in the small intestine, gastroduodenoscopy may be used for small intestinal foreign body removal. Case Presentation We describe here the case of a 21-month-old child in whom a 5-cm, sharp-pointed nail in the midjejunum was removed successfully by a gastroduodenoscopy. This case highlights the difficulties in the removal of a sharp foreign body in a pediatric patient and the use of push enteroscopy. Conclusion Gastroduodenoscopy can be used for the removal of a foreign body in the small intestine in pediatric population in a resource-limited setup by performing push enteroscopy.


Author(s):  
S.A. Karpishchenko ◽  
◽  
D.A. Usmanova ◽  
E.V. Bolozneva ◽  
E.S. Karpishchenko ◽  
...  

Maxillary sinus foreign bodies are interrelated with different types of treatment of pathologies of teeth of the maxilla. Foreign bodies can be presented by pins, sillers, impression materials, teeth, dental implants etc. Features of anatomical development of maxilla, degree of pneumatization of it and many other factors promote hit of the foreign body to the maxillary sinus. Detection of the foreign body in the maxillary sinus during the operation sometimes can become a serious technical difficulty and needs a surgeon to be a man of experience. Important part of success of the surgery is selection of access to the maxillary sinus based on the 3D computed tomography data. We represent a clinical case of treatment the patient with the maxillary sinus foreign body after two non-resultative surgeries. After the implantation of dental implant, patient appealed for medical treatment, complaining on the discomfort, passing pain at the right buccal region and secrete from the right part of nose. We know from the anamnesis, that the patient was operated through the anterior maxillary wall under the general anesthesia for two times. The foreign body was removed only during the third surgery, that was done under the local anesthesia under the control of the rigid endoscopes. The patient was conversed to the out-patient treatment at the day of the surgery. The efficacy of the endoscopic endonasal approach to the maxillary sinus through the inferior nasal meatus in case of maxillary sinus foreign body was approved.


Sign in / Sign up

Export Citation Format

Share Document