scholarly journals Transcutaneous Bilirubin Measurements Can Be Used to Measure Bilirubin Levels during Phototherapy

2018 ◽  
Vol 2018 ◽  
pp. 1-5 ◽  
Author(s):  
Saad Abdullah Alsaedi

Objective. To determine whether transcutaneous bilirubin measurements (TcB) before and during phototherapy taken from covered skin during phototherapy correlate with total serum bilirubin (TSB) levels.Study Design. In this prospective observational study, healthy term newborns who required TSB measurements were included. TcB measurements were taken from the forehead before starting and during phototherapy using the BiliChek device. Before starting phototherapy, part of the forehead was covered. Blood for TSB measurement was collected within 5 minutes of TcB measurements. Correlations and mean differences between TcB and TSB before and during phototherapy were calculated.Result. Paired TSB and TcB measurements before and during phototherapy in 151 newborns were performed. The mean gestational age was 38.8 weeks and birth weight was 3.1 kg; 53% were male. Before starting phototherapy, TSB and TcB were183.8±41.6and 190.5 ± 43 μmol/l, respectively. During phototherapy, TSB and TcB were191.8±39.4and187.8±45.3 μmol/l, respectively. Linear regression analysis showed a significant correlation between TcB and TSB before starting phototherapy and during phototherapy (r: 0.85;p<0.001andr: 80.0;p<0.001), respectively. Before starting phototherapy, the mean difference between TSB and TcB was6.2±23.2 μmol/l, with a 95% CI of −39.3 to 51.7 μmol. During phototherapy, the mean difference was −2.8±23.5 μmol/l, with a 95% CI of −48.9 to 43.3 μmol/l.Conclusion. TcB measurements from covered skin in jaundiced term infants during phototherapy correlate with TSB and can be used to monitor bilirubin levels during phototherapy.

2019 ◽  
Vol 40 (2) ◽  
pp. 226-231
Author(s):  
U. Costa-Posada ◽  
A. Concheiro-Guisán ◽  
M. F. Táboas- Ledo ◽  
E. González-Colmenero ◽  
M. L. González-Durán ◽  
...  

Abstract Objective Determine the suitability of transcutaneous bilirubin (TCB) as a tool to assess the effectiveness of phototherapy on patched skin. Study design A prospective observational study was conducted. We covered a fragment of skin (sternum) with a photo-opaque patch. Several simultaneous TCB and TSB measurements were performed with the JM-105 bilirubinometer. Bland and Altman test evaluated the agreement between bilirubin levels. Result A total of 217 patients were studied, 48.8% were preterm. The mean difference between TSB and TCB before the start of treatment was 1.07 mg/dL. During phototherapy, differences on covered skin were 0.52, 0.27, and 0.39 mg/dL at 24, 48, and 72 h of therapy respectively. The best correlation was observed at 48 h in preterm infants. Conclusion The measurement of TCB on patched skin (PTCB) is useful for monitoring the response to phototherapy in term and preterm infants. We use a patch with a removable flap that eases successive measures without disturbing the patients.


2019 ◽  
Vol 47 (5) ◽  
pp. 568-573 ◽  
Author(s):  
Abdón Castro ◽  
Carlos Zozaya ◽  
Mª Teresa Cuesta ◽  
Marina González ◽  
Gema Villar ◽  
...  

Abstract Background Transcutaneous bilirubinometers are a non-invasive tool to estimate serum bilirubin. However, once on phototherapy (PHT) and after PHT, its usefulness is precluded. The objective of this study was to prove the hypothesis that transcutaneous bilirubin (TcB) assessment in a covered skin area during PHT could be used to guide the duration of PHT in term and moderate-late preterm infants with non-isoimmune hyperbilirubinemia. Methods A small area of parasternal skin was covered before starting on PHT. Total serum and TcB (both in exposed and non-exposed areas) were determined before starting treatment, every 12 h once on PHT and 12 h after its discontinuation. Pearson’s correlation coefficient and paired mean differences between TcB and total serum bilirubin (TSB) were calculated. Bland-Altman plots were obtained. The percentage of correct treatment decisions made based on non-exposed TcB values was calculated. Results During PHT, there was a relatively good correlation between TSB and non-exposed TcB (0.74) estimates, in contrast to exposed TcB estimates (0.52). However, even when comparing non-exposed TcB with TSB, there was a wide range of agreement limits (−3.8 to 4.6 mg/dL). Decisions based on non-exposed TcB values would have been incorrect in 26.6% of the cases. Conclusion Although there is a relatively strong correlation between total serum and TcB in non-PHT-exposed regions, the difference is not narrow enough to be utilized in guiding clinical decisions on the duration of PHT.


2011 ◽  
Vol 51 (5) ◽  
pp. 256 ◽  
Author(s):  
Ari Kurniasih ◽  
Guslihan Dasa Tjipta ◽  
Muhammad Ali ◽  
Emil Azlin ◽  
Pertin Sianturi

Background Although phototherapy has been used in clinical practice for 40 years, there is still much debate on how to provide the most efficacious phototherapy. Phototherapy with white reflecting curtains may increase the average spectral irradiance provided, as well as decrease serum bilirubin concentrations at a faster rate in neonates with jaundice.Objective To determine if adding low cost, white, reflecting curtains to a standard phototherapy unit can increase the effectiveness of phototherapy for neonatal jaundice.Methods A randomized, controlled, open trial was conducted at H. Adam Malik and Pirngadi Hospitals, Medan, from May to December 2009. The criteria for inclusion in the study were full term newborns with neonatal jaundice presenting in their first week of life. Single phototherapy with white curtains hanging from the sides of the phototherapy unit (study group, n=30) was compared to single phototherapy without curtains (control group, n=30). The primary outcomes measured were the mean difference in total serum bilirubin levels and average spectral irradiation levels measured at baseline, and after 12 hours and 24 hours of phototherapy.Results The sum of average spectral irradiance in the curtained phototherapy unit was significantly higher than that of the standard phototherapy unit without curtains (P < 0.05). The decrease of total serum bilirubin levels after 12 and 24 hours of phototherapy was significantly greater in the study group (3.71 and 9.7 mg/dl, respectively) than in the control group (0.1 and 3.8 mg/dl, respectively), both P <0.05.Conclusion White, reflecting curtains in phototherapy units was significantly more effective than phototherapy without curtains for treatment of neonatal jaundice. [Paediatr Indones. 2011;51:256-61].


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Lile Zou ◽  
Huan Yu ◽  
Yuan He ◽  
Lijuan Luo ◽  
Wenbin Dong ◽  
...  

Abstract Inverse correlations between serum bilirubin level and obesity had been reported in adults. We aimed to investigate the associations between neonatal hyperbilirubinemia and childhood obesity. Data was obtained from the U.S. Collaborative Perinatal Project (CPP), a multicenter study from 1959 to 1976. Data of serum bilirubin in term newborns were used to observe the association with obesity at age of 7 years. Logistic regression models were performed to calculate adjusted odds ratios (aORs) for obesity. For children from the same mother sharing similar factors, Generalized Estimating Equation (GEE) model was used to correct for intracluster correlation. Relative to newborns with total serum bilirubin (TSB) < 3 mg/dl, there are lower risks for obesity in those with 3 mg/dl ≤ TSB < 6 mg/dl (aOR 0.91; 95%CI 0.81, 1.02), 6 mg/dl ≤ TSB < 9 mg/dl (aOR 0.88; 95%CI 0.78, 0.99), 9 mg/dl ≤ TSB<13 mg/dl (aOR 0.83; 95%CI 0.71, 0.98). By stratifying for subtypes of bilirubin, the inverse correlations only existed in exposure to unconjugated bilirubin. By using the GEE model correcting for intracluster correlations, the results are consistent. In summary, exposure to bilirubin up to 13 mg/dl is inversely associated with obesity at the age of 7 years in term infants.


2014 ◽  
Vol 115 (1-2) ◽  
pp. 33-42 ◽  
Author(s):  
Charalambos Neocleous ◽  
Alkistis Adramerina ◽  
Stefanos Limnaios ◽  
Symeon Symeonidis ◽  
Chrysoula Spanou ◽  
...  

The accuracy of transcutaneous bilirubin meters has been assessed in newborns from various ethnic backgrounds. However, there are limited data on Greek newborns. Our study examined the accuracy of transcutaneous bilirubin measurements in clinically jaundiced healthy-term Greek newborns, using total serum bilirubin as the reference standard, in order to re-evaluate our local guidelines about neonatal jaundice. Clinically jaundiced newborns requiring total serum bilirubin level estimation were recruited prospectively. 368 pairs of total serum bilirubin/transcutaneous bilirubin measurements were taken in 222 newborns, using a direct spectrophotometric device and the BiliCheck device, respectively. The level of agreement between the obtained transcutaneous bilirubin and total serum bilirubin values was assessed. Our data were analysed using the Stata/SE 12.0 (StataCorp LP, USA) statistical programme. The mean (± SD) TSB was 225.4 ± 25.4 μmol/l and the mean (± SD) TcB was 237.9 ± 21.0 μmol/l. The correlation between the values was poor (Pearson’s correlation coefficient 0.439; Lin’s concordance coefficient 0.377 [95% CI 0.301 to 0.453]; P<0.001). The Bland-Altman analysis demonstrated that transcutaneous bilirubin measurements tended to overestimate the total serum bilirubin value (mean difference 12.5 ± 24.9 μmol/l), with wide 95% limits of agreement (–36.2 μmol/l to 61.3 μmol/l). Transcutaneous bilirubin values did not correlate well with total serum bilirubin values, being often imprecise in predicting the actual total serum bilirubin levels. This permits us to continue estimating total serum bilirubin in clinically jaundiced newborns according to our local guidelines, in order to safely decide the appropriate care plan.


Neonatology ◽  
2021 ◽  
pp. 1-11
Author(s):  
Thivia Jegathesan ◽  
Douglas M. Campbell ◽  
Joel G. Ray ◽  
Vibhuti Shah ◽  
Howard Berger ◽  
...  

<b><i>Introduction:</i></b> Transcutaneous bilirubin (TcB) measurement offers a noninvasive approach for bilirubin screening; however, its accuracy in preterm infants is unclear. This study determined the agreement between TcB and total serum bilirubin (TSB) among preterm infants. <b><i>Methods:</i></b> A multisite prospective cohort study was conducted at 3 NICUs in Ontario, Canada, September 2016 to June 2018. Among 296 preterm infants born at 24<sup>0/7</sup> to 35<sup>6/7</sup> weeks, 856 TcB levels were taken at the forehead, sternum, and before and after the initiation of phototherapy with TSB measurements. Bland-Altman plots and 95% limits of agreement (LOA) expressed agreement between TcB and TSB. <b><i>Results:</i></b> The overall mean TcB-TSB difference was −24.5 μmol/L (95% LOA −103.3 to 54.3), 1.6 μmol/L (95% LOA −73.4 to 76.5) before phototherapy, and −31.1 μmol/L (95% LOA −105.5 to 43.4) after the initiation of phototherapy. The overall mean TcB-TSB difference was −15.2 μmol/L (95% LOA −86.8 to 56.3) at the forehead and −24.4 μmol/L (95% LOA −112.9 to 64.0) at the sternum. The mean TcB-TSB difference was −31.4 μmol/L (95% LOA −95.3 to 32.4) among infants born 24–28 weeks, −25.5 μmol/L (95% LOA −102.7 to 51.8) at 29–32 weeks, and −15.9 μmol/L (95% LOA −107.4 to 75.6) at 33–35 weeks. Measures did not differ by maternal ethnicity. <b><i>Conclusion:</i></b> Among preterm infants, TcB may offer a noninvasive, immediate approach to screening for hyperbilirubinemia with more careful use in preterm infants born at &#x3c;33 weeks’ gestation, as TcB approaches treatment thresholds. Its underestimation of TSB after the initiation of phototherapy warrants the use of TSB for clinical decision-making after the initiation of phototherapy.


1970 ◽  
Vol 42 (3) ◽  
pp. 194-198
Author(s):  
BO Kayode-Adedeji ◽  
JA Owa ◽  
GO Akpede ◽  
SO Alikah

Background: The objective assessment of the severity of neonatal jaundice is Total Serum Bilirubin (TSB) determination, which requires multiple blood sampling. This has inherent problems, including risks of anaemia and infection. Transcutaneous Bilirubinometry (TcB) is a reliable, non-invasive alternative, however there is paucity of data on its performance in black preterm neonates.Objectives: To evaluate the correlation between transcutaneous bilirubin (TcB) and total serum bilirubin (TSB) among Nigerian preterm neonates, and to determine the parameters affecting the relationship.Method: Jaundiced preterm neonates delivered between 28 and 36 weeks of gestation admitted at the Irrua Specialist Teaching Hospital (ISTH), Nigeria were recruited . The TSB levels were determined by spectrophotometry while the corresponding TcB levels were obtained using Jaundice Meter (JM-103). The neonates were stratified into gestational age and birth weight groups.Results: A total of 189 paired TcB and TSB levels were obtained from 60 neonates. The Mean (sd) TcB level of 11.4 (3.1) mg/dl was significantly higher than the mean TSB level of 10.2 (2.8)mg/dl (p= 0.028). The overall correlation coefficient between TcB and TSB was 0.98 and it was not significantly affected by the gestational age, birth weight and bilirubin levels.Conc lusion: Transcutneous bilirubin strongly correlates with total serum bilirubin levels among Nigerian preterm neonates, irrespective of gestational age, birth weight and the degree of jaundice.Keywords: hyperbiliruinaemia, jaundice meter, Nigerian, preterm, neonates, transcutaneous bilirubinometry


2014 ◽  
Vol 12 (1) ◽  
pp. 11-15 ◽  
Author(s):  
Cristiane Maria da Conceição ◽  
Maria Fernanda Pellegrino da Silva Dornaus ◽  
Maria Aparecida Portella ◽  
Alice D’Agostini Deutsch ◽  
Celso Moura Rebello

Objective : To investigate the influence of the site of measurement of transcutaneous bilirubin (forehead or sternum) in reproducibility of results as compared to plasma bilirubin. Methods : A cohort study including 58 term newborns with no hemolytic disease. Transcutaneous measurements were performed on the forehead (halfway between the headline and the glabella, from the left toward the right side, making consecutive determinations, one-centimeter apart) and the sternum (five measurements, from the suprasternal notch to the xiphoid process with consecutive determinations, one-centimeter apart) using Bilicheck® (SpectRx Inc, Norcross, Georgia, USA). The correlation and agreement between both methods and plasma bilirubin were calculated. Results : There was a strong linear correlation between both determinations of serum bilirubin at the forehead and sternum (r=0.704; p<0.01 and r=0.653; p<0.01, respectively). There was correspondence of the mean values of transcutaneous bilirubin measured on the sternum (9.9±2.2mg/dL) compared to plasma levels (10.2±1.7mg/dL), but both differ from the values measured on the forehead (8.6±2.0mg/dL), p<0.05. Conclusion : In newborn term infants with no hemolytic disease, measuring of transcutaneous bilirubin on the sternum had higher accuracy as compared to serum bilirubin measurement on the forehead.


2021 ◽  
Vol In Press (In Press) ◽  
Author(s):  
Sinan T&uuml;fekci ◽  
Erhan Aygün

Background: There are limited data about the proper transcutaneous bilirubin measuring time to detect levels that are close to serum bilirubin levels after ending the phototherapy treatment. Objectives: To compare the transcutaneous bilirubin and total serum bilirubin levels, and to evaluate the reliability of transcutaneous bilirubin measurements after phototherapy treatment of newborns because of hyperbilirubinemia. Methods: The study included 105 late preterm and term newborns consisting of 56 females (53.3%) and 49 males (46.6%), with gestational age 350/7 - 416/7 weeks who were treated with phototherapy. A Bilicheck (M&B-MBJ20) device was used for transcutaneous bilirubin measurements. The average of three measurements on the skin in the mid-sternal area were obtained. Correlations between transcutaneous bilirubin and venous bilirubin levels were evaluated 6 and 12 hours after phototherapy. Transcutaneous bilirubin measurements were performed simultaneously with blood collection or within a maximum ± 15 minutes time difference for total serum bilirubin. Results: The average phototherapy time was 10 ± 2 (range, 8 - 12) hours. The average difference between transcutaneous bilirubin and venous bilirubin levels post phototherapy was 2.61 mg/dL after 6 hours and 0.8 mg/dL after 12 hours. The hematocrit levels of the patients ranged between 40 - 66% with an average of 53% ± 4.8, the median level was 51%. Correlation coefficients according to hours after treatment were high for the 6th hour (r = 0.76) and very high for the 12th hour. Conclusions: Jaundice scanning with transcutaneous bilirubin measurements 6 - 12 hours after the end of phototherapy is reliable and may be helpful in preventing additional blood collection from the heel.


2017 ◽  
Vol 57 (1) ◽  
pp. 8 ◽  
Author(s):  
Andra Kurnianto ◽  
Herman Bermawi ◽  
Afifa Darmawanti ◽  
Erial Bahar

Background The gold standard for diagnosis of neonatal jaundice is total serum bilirubin (TSB) measurement. This method, however, is invasive, painful, and costly in terms of workload, time, and money. Moreover, repeated blood sampling may lead to significant blood loss, which is of particular concern in preterm infants. To overcome these drawbacks, non-invasive methods of bilirubin measurement have been proposed. Transcutaneous bilirubinometry (TcB) determines the yellowness of the subcutaneous tissue of a newborn infant by measuring the difference between optical densities for light in the blue and green wavelength regions.Objective To evaluate the accuracy of transcutaneous bilirubinometry for estimating TSB levels in neonatal jaundice.Methods Subjects were infants aged < 28 days with jaundice who had never been treated with phototherapy or exchange transfusion. The study was done from February to July 2016 in Mohammad Hoesin Hospital. Subjects underwent transcutaneous bilirubin (TcB) and TSB assays, with a maximum interval of 15 minutes between tests.Results One hundred fifty patients were included in this study. The TcB values > 5 mg/dL were correlated to TSB > 5 mg/dL, with 100% sensitivity and 83.3% specificity. This cut-off point was obtained from a receiver-operator characteristic (ROC) curve with AUC 99.3% (95%CI 97.9 to 100%; P< 0.001).The correlation coefficients (r) for TSB and TcB measurements on the forehead were 0.897 (P<0.001).Conclusion Transcutaneous bilirubinometry can be used to accurately estimate TSB levels in neonatal jaundice, and may be useful in clinical practice as a non-invasive method to reduce blood sampling.