Energy and exergy analysis of a downstream single-row air washer at different droplet diameters for air cooling application

Author(s):  
Minhua Huang ◽  
Haiqiao Wang ◽  
Feng Tian ◽  
Junxin Huang ◽  
Shiqiang Chen ◽  
...  

This study proposes a downstream single-row air washer for air cooling. The theoretical energy and exergy balance models were established at different droplet diameters and verified by the experimental data. Based on the abovementioned theoretical relationship, the single performance indicator of heat exchange efficiency (HEE) and exergy efficiency was quantitatively analyzed; a comprehensive analysis method of two indicators was proposed, combining HEE and exergy efficiency, and a numerical simulation was carried out. Results show that the smaller the droplet diameter and the larger the water–air ratio, the lower the dry-bulb temperature of the outlet air and the higher the HEE and exergy flux destruction. When the droplet diameter is less than 440 μm, the droplet diameter does not affect exergy efficiency and dry-bulb temperature. When the droplet diameter is larger than 440 μm, the droplet diameter is positively correlated with the air outlet dry-bulb temperature and exergy efficiency; in contrast, the water–gas ratio is negatively correlated with the air outlet dry-bulb temperature. An engineering case reveals that when the air outlet temperature is less than 34°C, the critical water–gas ratio can be set as 2.6 (mass ratio). At this time, the HEE is more than 90%, the exergy efficiency is more than 60%, and the critical value of droplet diameter is 440 μm. The research results provide an essential theoretical basis for the optimization of engineering design calculation.

Author(s):  
Mohammed El Hadi Attia ◽  
Abd Elnaby Kabeel ◽  
Abdelkader Bellila ◽  
Athikesavan Muthu Manokar ◽  
Ravishankar Sathyamurthy ◽  
...  

2020 ◽  
Vol 5 (1) ◽  
pp. 563-572
Author(s):  
Iman Golpour ◽  
Mohammad Kaveh ◽  
Reza Amiri Chayjan ◽  
Raquel P. F. Guiné

AbstractThis research work focused on the evaluation of energy and exergy in the convective drying of potato slices. Experiments were conducted at four air temperatures (40, 50, 60 and 70°C) and three air velocities (0.5, 1.0 and 1.5 m/s) in a convective dryer, with circulating heated air. Freshly harvested potatoes with initial moisture content (MC) of 79.9% wet basis were used in this research. The influence of temperature and air velocity was investigated in terms of energy and exergy (energy utilization [EU], energy utilization ratio [EUR], exergy losses and exergy efficiency). The calculations for energy and exergy were based on the first and second laws of thermodynamics. Results indicated that EU, EUR and exergy losses decreased along drying time, while exergy efficiency increased. The specific energy consumption (SEC) varied from 1.94 × 105 to 3.14 × 105 kJ/kg. The exergy loss varied in the range of 0.006 to 0.036 kJ/s and the maximum exergy efficiency obtained was 85.85% at 70°C and 0.5 m/s, while minimum exergy efficiency was 57.07% at 40°C and 1.5 m/s. Moreover, the values of exergetic improvement potential (IP) rate changed between 0.0016 and 0.0046 kJ/s and the highest value occurred for drying at 70°C and 1.5 m/s, whereas the lowest value was for 70°C and 0.5 m/s. As a result, this knowledge will allow the optimization of convective dryers, when operating for the drying of this food product or others, as well as choosing the most appropriate operating conditions that cause the reduction of energy consumption, irreversibilities and losses in the industrial convective drying processes.


Author(s):  
Mohammed El Hadi Attia ◽  
Abd Elnaby Kabeel ◽  
Abdelkader Bellila ◽  
Athikesavan Muthu Manokar ◽  
Ravishankar Sathyamurthy ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4522
Author(s):  
Zude Cheng ◽  
Haitao Wang ◽  
Junsheng Feng ◽  
Yongfang Xia ◽  
Hui Dong

In order to fully understand the energy and exergy transfer processes in sinter vertical coolers, a simulation model of the fluid flow and heat transfer in a vertical cooler was established, and energy and exergy efficiency analyses of the gas–solid heat transfer in a vertical cooler were conducted in detail. Based on the calculation method of the whole working condition, the suitable operational parameters of the vertical cooler were obtained by setting the net exergy efficiency in the vertical cooler as the indicator function. The results show that both the quantity of sinter waste heat recovery (SWHR) and energy efficiency increased as the air flow rate (AFR) increased, and they decreased as the air inlet temperature (AIT) increased. The increase in the sinter inlet temperature (SIT) resulted in an increase in the quantity of SWHR and a decrease in energy efficiency. The air net exergy had the maximum value as the AFR increased, and it only increased monotonically as the SIT and AIT increased. The net exergy efficiency reached the maximum value as the AFR and AIT increased, and the increase in the SIT only resulted in a decrease in the net exergy efficiency. When the sinter annual production of a 360 m2 sintering machine was taken as the processing capacity of the vertical cooler, the suitable operational parameters of the vertical cooler were 190 kg/s for the AFR, and 353 K for the AIT.


Author(s):  
M. Bianchi ◽  
F. Melino ◽  
A. Peretto ◽  
P. R. Spina ◽  
S. Ingistov

In the last years, among all different gas turbine inlet air cooling techniques, an increasing attention to fogging approach is dedicated. The various fogging strategies seem to be a good solution to improve gas turbine or combined cycle produced power with low initial investment cost and less installation downtime. In particular, overspray fogging and interstage injection involve two-phase flow consideration and water evaporation during compression process (also known as wet compression). According to the Author’s knowledge, the field of wet compression is not completely studied and understood. In the present paper, all the principal aspects of wet compression and in particular the influence of injected water droplet diameter and surface temperature, and their effect on gas turbine performance and on the behavior of the axial compressor (change in axial compressor performance map due to the water injection, redistribution of stage load, etc.) are analyzed by using a calculation code, named IN.FO.G.T.E. (INterstage FOgging Gas Turbine Evaluation), developed and validated by the Authors.


2021 ◽  
Author(s):  
Pavel Dmitrievich Gladkov ◽  
Anastasiia Vladimirovna Zheltikova

Abstract As is known, fractured reservoirs compared to conventional reservoirs have such features as complex pore volume structure, high heterogeneity of the porosity and permeability properties etc. Apart from this, the productivity of a specific well is defined above all by the number of natural fractures penetrated by the wellbore and their properties. Development of fractured reservoirs is associated with a number of issues, one of which is related to uneven and accelerated water flooding due to water breakthrough through fractures to the wellbores, for this reason it becomes difficult to forecast the well performance. Under conditions of lack of information on the reservoir structure and aquifer activity, the 3D digital models of the field generated using the hydrodynamic simulators may feature insufficient predictive capability. However, forecasting of breakthroughs is important in terms of generating reliable HC and water production profiles and decision-making on reservoir management and field facilities for produced water treatment. Identification of possible sources of water flooding and planning of individual parameters of production well operation for the purpose of extending the water-free operation period play significant role in the development of these reservoirs. The purpose of this study is to describe the results of the hydrochemical monitoring to forecast the water flooding of the wells that penetrated a fractured reservoir on the example of a gas condensate field in Bolivia. The study contains data on the field development status and associated difficulties and uncertainties. The initial data were results of monthly analyses of the produced water and the water-gas ratio dynamics that were analyzed and compared to the data on the analogue fields. The data analysis demonstrated that first signs of water flooding for the wells of the field under study may be diagnosed through the monitoring of the produced water mineralization - the water-gas ratio (WGR) increase is preceded by the mineralization increase that may be observed approximately a month earlier. However, the data on the analogue fields shows that this period may be longer – from few months to two years. Thus, the hydrochemical method within integrated monitoring of development of a field with a fractured reservoir could be one of the efficient methods to timely adjust the well operation parameters and may extend the water-free period of its operation.


Energies ◽  
2018 ◽  
Vol 11 (8) ◽  
pp. 2094 ◽  
Author(s):  
Mustafa Erguvan ◽  
David MacPhee

In this study, energy and exergy analyses have been investigated numerically for unsteady cross-flow over heated circular cylinders. Numerous simulations were conducted varying the number of inline tubes, inlet velocity, dimensionless pitch ratios and Reynolds number. Heat leakage into the domain is modeled as a source term. Numerical results compare favorably to published data in terms of Nusselt number and pressure drop. It was found that the energy efficiency varies between 72% and 98% for all cases, and viscous dissipation has a very low effect on the energy efficiency for low Reynolds number cases. The exergy efficiency ranges from 40–64%, and the entropy generation due to heat transfer was found to have a significant effect on exergy efficiency. The results suggest that exergy efficiency can be maximized by choosing specific pitch ratios for various Reynolds numbers. The results could be useful in designing more efficient heat recovery systems, especially for low temperature applications.


2018 ◽  
Vol 4 (2) ◽  
pp. 149-154
Author(s):  
Aleksey Kulikov ◽  
Andrey Lepyokhin ◽  
Vitaly Polunichev

The purpose of the work was to optimize the parameters of the spillage system equipped with a gas pressure hydroaccumulator for a ship pressurized water reactor in a loss-of-coolant accident. The water-gas ratio in the hydroaccumulator and the hydraulic resistance of the path between the hydroaccumulator and the reactor were optimized at the designed hydroaccumulator geometric volume. The main dynamic processes were described using a mathematical model and a computational analysis. A series of numerical calculations were realized to simulate the behavior dynamics of the coolant level in the reactor during the accident – by varying the optimized parameters. Estimates of the minimum and maximum values of the coolant level were obtained: depending on the initial water-gas ratio in the hydroaccumulator at different diameters of the flow restrictor on the path between the hydroaccumulator and the reactor. These results were obtained subject to the restrictive conditions that, during spillage, the coolant level should remain above the core and below the blowdown nozzle. The first condition implies that the core is in safe state, the second excludes the coolant water blowdown. The optimization goal was to achieve the maximum time interval in which these conditions would be satisfied simultaneously. The authors propose methods for selecting the optimal spillage system parameters; these methods provide the maximum time for the core to be in a safe state during a loss-of-coolant accident at the designed hydroaccumulator volume. Using these methods, it is also possible to make assessments from the early stages of designing reactor plants.


Sign in / Sign up

Export Citation Format

Share Document