Determination of cost-efficient cooling power range for improving the performance of internally cooled ultrasonic atomization liquid desiccant dehumidifiers

2020 ◽  
Vol 29 (9) ◽  
pp. 1260-1276
Author(s):  
Zili Yang ◽  
Lu-An Chen ◽  
Ruiyang Tao ◽  
Ke Zhong

Liquid desiccant dehumidifiers (LDDs) can be improved by adding internal cooling. However, the addition of excessive cooling power may deteriorate the system‘s cost-efficiency, whereas the addition of insufficient cooling power leads to negligible performance improvements. The objective of this study is to determine the suitable cost-efficient cooling power range for improving the performance of internally cooled LDDs (IC-LDDs). A novel method and a set of criteria related to the moisture removal rate, cooling-power efficiency ( ηc) and coefficient of dehumidification performance from cooling power ( DCOPcooling) were proposed to determine cost-efficient cooling power. The internally cooled ultrasonic atomization liquid desiccant system (IC-UADS), together with a well-validated model based on the conservation laws of mass and energy and the sensible heat balance, was adopted to demonstrate the analysis. The results showed that, although the dehumidification performance improves with increasing cooling power, the improvement rate decreases, while ηcand DCOPcoolingdecline quickly (by 87.9%). For cost-efficient improvement, the necessary power proportion of internal cooling to the system‘s target dehumidification capacity tends to be stable, which was about 29% for the IC-UADS, and independent of the operating conditions. The results may help to determine the reasonable cooling power range for cost-efficient improvement of IC-LDDs.

2014 ◽  
Vol 875-877 ◽  
pp. 1205-1213 ◽  
Author(s):  
Mohamed M. Bassuoni

The dehumidifier is a key component in liquid desiccant air conditioning systems. Various mathematical models of heat and mass transfer processes inside the dehumidifier are introduced and numerically solved in the literature. Analytical solutions have more advantages than numerical solutions in studying the dehumidifier performance parameters. This paper presents the results from an analytical model for the performance of an adiabatic cross flow liquid desiccant air dehumidifier. Calcium chloride is used as desiccant material in this investigation. Both humidity and temperature effectiveness of the dehumidifier are used to predict the performance of the device under various operating conditions. Good accuracy has been found between analytical solution and reliable experimental results with a maximum deviation of +6.63% and -5.65% in the moisture removal rate. The method developed here can be used in the quick prediction of the dehumidifier performance. The exit parameters from the dehumidifier are evaluated under the effects of variables such as air temperature and humidity, desiccant temperature and concentration and air to desiccant flow rates. The results show that hot humid air and desiccant concentration have the greatest impact on the performance of the dehumidifier.


2016 ◽  
Vol 138 (3) ◽  
Author(s):  
Ahmed H. Abdel-Salam ◽  
Chris McNevin ◽  
Lisa Crofoot ◽  
Stephen J. Harrison ◽  
Carey J. Simonson

The field performance of a low-flow internally cooled/heated liquid desiccant air conditioning (LDAC) system is investigated in this paper. The quasi-steady performance (sensible and latent heat transfer rates, coefficient of performance (COP), and uncertainties) of the LDAC system is quantified under different ambient air conditions. A major contribution of this work is a direct comparison of the transient and quasi-steady performance of the LDAC system. This paper is the first to quantify the importance of transients and shows that, for the environmental and operating conditions in this paper, transients can be neglected when estimating the energy consumption of the LDAC system. Another major contribution of this work is the development and verification of a new method that quantifies (with acceptable uncertainties) the quasi-steady performance of a LDAC system from transient field data using average data.


Author(s):  
I. P. Koronaki ◽  
R. I. Christodoulaki ◽  
V. D. Papaefthimiou ◽  
E. D. Rogdakis

Liquid desiccant air conditioning systems have recently been attracting attention due to their capability of handling the latent load without super-cooling and then reheating the air, as happens in a conventional compression-type air conditioning system. This paper presents the results from a study of the performance of an internally cooled liquid desiccant dehumidifier. A plate heat exchanger is proposed as the internally cooled element of the dehumidifier and water as the cooling fluid. The desiccant solution is sprayed into the internally cooled dehumidifier from the top and flows down by gravity. At the same time, fresh humid air is blown from the bottom or top, counter-flowing or co-flowing with the desiccant solution. The desiccant is in direct contact with the air, allowing for heat and mass transfer. The cooling water, flowing inside the plates of the dehumidifier, carries out the heat of the crossed air and solution. A heat and mass transfer theoretical model has been developed, based on the Runge-Kutta fixed step method, to predict the performance of the device under various operating conditions. Experimental data from previous literature have been used to validate the model. Excellent agreement has been found between experimental tests and the theoretical model, with the deviation not exceeding ±4.1% for outlet air temperature and ±4.0% for outlet humidity ratio. Following the validation of the mathematical model, the dominating effects on the absorption process have been discussed in detail. Namely, effects of flow configuration, air inlet temperature, humidity and flow rate, as well as desiccant inlet temperature, concentration and flow rate have been investigated against the dehumidification rate and the cooling efficiency. The two most commonly used liquid desiccant solutions, namely LiCl and LiBr have been also evaluated against each other. The results suggested that high dehumidification mass rate can be achieved under counter flow between air and solution, low air mass flow rates, low cooling water temperature, low desiccant temperature and LiCl as the desiccant solution.


2021 ◽  
pp. 1-21
Author(s):  
Z. Hao ◽  
X. Yang ◽  
Z. Feng

Abstract Particulate deposits in aero-engine turbines change the profile of blades, increase the blade surface roughness and block internal cooling channels and film cooling holes, which generally leads to the degradation of aerodynamic and cooling performance. To reveal particle deposition effects in the turbine, unsteady simulations were performed by investigating the migration patterns and deposition characteristics of the particle contaminant in a one-stage, high-pressure turbine of an aero-engine. Two typical operating conditions of the aero-engine, i.e. high-temperature take-off and economic cruise, were discussed, and the effects of particle size on the migration and deposition of fly-ash particles were demonstrated. A critical velocity model was applied to predict particle deposition. Comparisons between the stator and rotor were made by presenting the concentration and trajectory of the particles and the resulting deposition patterns on the aerofoil surfaces. Results show that the migration and deposition of the particles in the stator passage is dominated by the flow characteristics of fluid and the property of particles. In the subsequential rotor passage, in addition to these factors, particles are also affected by the stator–rotor interaction and the interference between rotors. With higher inlet temperature and larger diameter of the particle, the quantity of deposits increases and the deposition is distributed mainly on the Pressure Side (PS) and the Leading Edge (LE) of the aerofoil.


2014 ◽  
Vol 703 ◽  
pp. 171-174
Author(s):  
Bing Wang ◽  
Yi Xiao ◽  
Shou Hui Tong ◽  
Lan Fang ◽  
Da Hai You ◽  
...  

Improved step-feed de-nitrification progress combined with biological fluidized bed was introduced in this study. The progress had good performance and capacity of de-nitrification and organic matter. The experiment result showed that the de-nitrification efficiency of the improved biological fluidized bed with step-feed process was higher than the fluidized bed A/O process under the same water quality and the operating conditions. When the influent proportion of each segment was equal, the system showed good nitrogen removal efficiency with the change of influent C/N ratio, HRT and sludge return ratio. The removal rate of TN reached up to 88.2%. It showed that the simultaneous nitrification and de-nitrification phenomenon happened in the aerobic zone. The nitrogen removal mechanism was also studied.


2021 ◽  
pp. 004051752110449
Author(s):  
Huihui Wang ◽  
Tong Shu ◽  
Pandeng Li ◽  
Yun Bai ◽  
Mengxiong Xiang ◽  
...  

Ramie fiber is known as the “king of natural fibers,” and the key to its wide application is efficient and green manufacturing. Microbial degumming has gradually become a hot area of research due to its environmental protection and mild operating conditions. However, some gummy materials remain after microbial degumming. Xylan is the main component of residual gums; its acetylated branched chains create the space barrier that makes the removal of hemicellulose difficult during ramie degumming. An acetyl xylan esterase (AXE) was obtained from Bacillus pumilus and characterized to solve this problem. Its optimum temperature and pH were 35°C and 8.0, respectively, and it had good temperature and pH stability. These properties were consistent with the conditions of ramie degumming and they laid a foundation for the application of AXE in ramie degumming. Besides, an engineered strain with a high activity of AXE was constructed successfully on the basis of the wild-type degumming strain Pectobacterium carotovorum HG-49 and used for ramie degumming. The removal rate of hemicellulose and total gums by the engineered strain increased by 4.89% and 2.53%, respectively, compared with that of the wild-type strain. Moreover, the role of this AXE in ramie degumming was further proven by X-ray diffraction and scanning electron microscopy. This study showed that AXE played an important role in the removal of hemicellulose in the degumming process of ramie fibers, thus providing a promising degumming strategy for ramie and other bast fiber plants.


2001 ◽  
Author(s):  
E. D. Rogdakis ◽  
V. D. Papaefthimiou

Abstract It is a general trend today, the old centrifugal machines to be replaced by new absorption machines. The mass flow rate of the cooling water in the centrifugal machines is normally 30% less than that in the two-stage absorption chiller for the same refrigerating capacity. Some absorption chillers manufacturers have updated and improved the double-effect technology increasing the cooling water temperature difference from the typical value of 5.5°C to 7.4°C and reducing the cooling water flow rate by about 30%. Using such a modern double effect absorption unit to replace a centrifugal chiller the same cooling water circuit can be used and the total cost of the retrofit is minimized. In this case a new flow pattern of the cooling tower is developed, and in this paper the design of a new tower fill is predicted taking into account the new factors characterizing the operating conditions and the required performance of the tower. As an example, the operational curves of a modified cooling tower (1500 KW cooling power) used by a 240 RT double-effect absorption chiller are presented.


Sign in / Sign up

Export Citation Format

Share Document