scholarly journals The combination of high sensitivity troponin T and copeptin facilitates early rule-out of ACS: a prospective observational study

2013 ◽  
Vol 13 (1) ◽  
Author(s):  
Johan Thelin ◽  
Catharina Borna ◽  
David Erlinge ◽  
Bertil Öhlin
CJEM ◽  
2018 ◽  
Vol 20 (S1) ◽  
pp. S28-S28
Author(s):  
A. D. McRae ◽  
S. Vatanpour ◽  
J. Ji ◽  
H. Yang ◽  
D. Southern ◽  
...  

Introduction: Patients with chronic kidney disease (CKD) are at high risk of cardiovascular events, and have worse outcomes following acute myocardial infarction (AMI). Cardiac troponin is often elevated in CKD, making the diagnosis of AMI challenging in this population. We sought to quantify test characteristics for AMI of a high-sensitivity troponin T (hsTnT) assay performed at emergency department (ED) arrival in CKD patients with chest pain, and to derive rule-out cutoffs specific to patient subgroups stratified by estimated glomerular filtration rate (eGFR). We also quantified the sensitivity and classification performance of the assays limit of detection (5 ng/L) and the FDA-approved limit of quantitation (6 ng/L) for ruling out AMI at ED arrival. Methods: Consecutive patients in four urban EDs from the 2013 calendar year with suspected cardiac chest pain who had a Roche Elecsys hsTnT assay performed on arrival were included f. This analysis was restricted to patients with an eGFR< 60 ml/min/1.73m2. The primary outcome was 7-day AMI. Secondary outcomes included major adverse cardiac events (death, AMI and revascularization). Test characteristics were calculated and ROC curves were generated for eGFR subgroups. Results: 1416 patients were included. 7-day AMI incidence was 10.1%. 73% of patients had an initial hsTnT concentration greater than the assays 99th percentile (14 ng/L). TCurrently accepted cutoffs to rule out MI at ED arrival ( 5 ng/L and 6 ng/L) had 100% sensitivity for AMI, but no patients with an eGFR less than 30 ml/min/1.73M had hsTnT concentrations below these thresholds. We derived eGFR-adjusted cutoffs to rule out MI with sensitivity >98% at ED arrival, which were able to rule out 6-42% of patients, depending on eGFR category. The proportion of patients able to be accurately ruled-in with a single hsTnT assay was substantially lower among patients with an eGFR <30 ml/min/1.73m2 (6-20% vs 25-43%). We also derived eGFR-adjusted cutoffs to rule-in AMI with specificity >90%, which accurately ruled-in up to 18% of patients. Conclusion: Cutoffs achieving acceptable diagnostic performance for AMI using single hsTnT sampling on ED arrival may have limited clinical utility, particularly among patients with very low eGFR. The ideal diagnostic strategy for AMI in patients with CKD likely involves serial high-sensitivity troponin testing with diagnostic thresholds customized to different eGFR categories.


2016 ◽  
Vol 23 (9) ◽  
pp. 1004-1013 ◽  
Author(s):  
Richard Body ◽  
Christian Mueller ◽  
Evangelos Giannitsis ◽  
Michael Christ ◽  
Jorge Ordonez-Llanos ◽  
...  

Circulation ◽  
2018 ◽  
Vol 138 (18) ◽  
pp. 2061-2063 ◽  
Author(s):  
Rebecca Vigen ◽  
Patricia Kutscher ◽  
Fernabelle Fernandez ◽  
Amy Yu ◽  
Bryan Bertulfo ◽  
...  

2017 ◽  
Vol 8 (5) ◽  
pp. 404-411 ◽  
Author(s):  
Jack Marjot ◽  
Thomas E Kaier ◽  
Katherine Henderson ◽  
Laura Hunter ◽  
Michael S Marber ◽  
...  

Aims: In 2015, the European Society of Cardiology introduced new guidelines for the diagnosis of acute coronary syndromes in patients presenting without persistent ST-segment elevation. These guidelines included the use of high-sensitivity troponin assays for ‘rule-in’ and ‘rule-out’ of acute myocardial injury at presentation (using a ‘0 hour’ blood test). Whilst these algorithms have been extensively validated in prospective diagnostic studies, the outcome of their implementation in routine clinical practice has not been described. The present study describes the change in the patient journey resulting from implementation of such an algorithm in a busy innercity Emergency Department. Methods and results: Data were prospectively collected from electronic records at a large Central London hospital over seven months spanning the periods before, during and after the introduction of a new high-sensitivity troponin rapid diagnostic algorithm modelled on the European Society of Cardiology guideline. Over 213 days, 4644 patients had high-sensitivity troponin T measured in the Emergency Department. Of these patients, 40.4% could be ‘ruled-out’ based on the high-sensitivity troponin T concentration at presentation, whilst 7.6% could be ‘ruled-in’. Adoption of the algorithm into clinical practice was associated with a 37.5% increase of repeat high-sensitivity troponin T measurements within 1.5 h for those patients classified as ‘intermediate risk’ on presentation. Conclusions: Introduction of a 0 hour ‘rule-in’ and ‘rule-out’ algorithm in routine clinical practice enables rapid triage of 48% of patients, and is associated with more rapid repeat testing in intermediate risk patients.


2011 ◽  
Vol 29 (10) ◽  
pp. 805-810 ◽  
Author(s):  
Sally Aldous ◽  
Chris Pemberton ◽  
A Mark Richards ◽  
Richard Troughton ◽  
Martin Than

Sign in / Sign up

Export Citation Format

Share Document