Does Arterial Oxygen Saturation Influence the Relationship Between Hemoglobin Mass and VO2peak at Moderate Altitude?

2016 ◽  
Vol 48 ◽  
pp. 302
Author(s):  
Jesse A. Goodrich ◽  
Benjamin J. Ryan ◽  
William C. Byrnes
2003 ◽  
Author(s):  
Stephen R. Muza ◽  
Paul B. Rock ◽  
Michael Zupan ◽  
James Miller ◽  
William R. Thomas

Author(s):  
Mercedes J. Nagel ◽  
Caitlin P. Jarrard ◽  
Sophie Lalande

Intermittent hypoxia, defined as alternating bouts of breathing hypoxic and normoxic air, has the potential to improve oxygen-carrying capacity through an erythropoietin-mediated increase in hemoglobin mass. The purpose of this study was to determine the effect of a single session of intermittent hypoxia on erythropoietin levels and hemoglobin mass in young healthy individuals. Nineteen participants were randomly assigned to an intermittent hypoxia group (Hyp, n = 10) or an intermittent normoxia group (Norm, n = 9). Intermittent hypoxia consisted of five 4-min hypoxic cycles at a targeted arterial oxygen saturation of 90% interspersed with 4-min normoxic cycles. Erythropoietin levels were measured before and two hours following completion of the protocol. Hemoglobin mass was assessed the day before and seven days after exposure to intermittent hypoxia or normoxia. As expected, the intermittent hypoxia group had a lower arterial oxygen saturation than the intermittent normoxia group during the intervention (Hyp: 89 ± 1 vs. Norm: 99 ± 1%, p < 0.01). Erythropoietin levels did not significantly increase following exposure to intermittent hypoxia (Hyp: 8.2 ± 4.5 to 9.0 ± 4.8, Norm: 8.9 ± 1.7 to 11.1 ± 2.1 mU·mL−1, p = 0.15). Hemoglobin mass did not change following exposure to intermittent hypoxia. This single session of intermittent hypoxia was not sufficient to elicit a significant rise in erythropoietin levels or hemoglobin mass in young healthy individuals.


2003 ◽  
Author(s):  
Stephen R. Muza ◽  
Paul B. Rock ◽  
Michael Zupan ◽  
James Miller ◽  
William R. Thomas ◽  
...  

2007 ◽  
Vol 8 (4) ◽  
pp. 296-306 ◽  
Author(s):  
Edgar Cristancho ◽  
Orlando Reyes ◽  
Mauricio Serrato ◽  
María Mercedes Mora ◽  
Joel Alberto Rojas ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shinshu Katayama ◽  
Jun Shima ◽  
Ken Tonai ◽  
Kansuke Koyama ◽  
Shin Nunomiya

AbstractRecently, maintaining a certain oxygen saturation measured by pulse oximetry (SpO2) range in mechanically ventilated patients was recommended; attaching the INTELLiVENT-ASV to ventilators might be beneficial. We evaluated the SpO2 measurement accuracy of a Nihon Kohden and a Masimo monitor compared to actual arterial oxygen saturation (SaO2). SpO2 was simultaneously measured by a Nihon Kohden and Masimo monitor in patients consecutively admitted to a general intensive care unit and mechanically ventilated. Bland–Altman plots were used to compare measured SpO2 with actual SaO2. One hundred mechanically ventilated patients and 1497 arterial blood gas results were reviewed. Mean SaO2 values, Nihon Kohden SpO2 measurements, and Masimo SpO2 measurements were 95.7%, 96.4%, and 96.9%, respectively. The Nihon Kohden SpO2 measurements were less biased than Masimo measurements; their precision was not significantly different. Nihon Kohden and Masimo SpO2 measurements were not significantly different in the “SaO2 < 94%” group (P = 0.083). In the “94% ≤ SaO2 < 98%” and “SaO2 ≥ 98%” groups, there were significant differences between the Nihon Kohden and Masimo SpO2 measurements (P < 0.0001; P = 0.006; respectively). Therefore, when using automatically controlling oxygenation with INTELLiVENT-ASV in mechanically ventilated patients, the Nihon Kohden SpO2 sensor is preferable.Trial registration UMIN000027671. Registered 7 June 2017.


Sign in / Sign up

Export Citation Format

Share Document